AC-DC 80-240 Watts xppower.com DRS80-240 Series • Ultra Slim Cases • 150% Peak Load for 4 seconds • Wide Output Adjustment Range • High Efficiency – Up to 92% • 12 V, 24 V & 48 V Versions • Low Output Ripple & Noise • -20 ºC to 70 ºC Operating Temperature Specification Input General Input Voltage Input Frequency Input Current • 85-264 VAC • 47-63 Hz • 80 W: 2 A at 85 VAC 120 W: 2 A at 85 VAC 240 W: 4 A at 85 VAC Inrush Current • 30 A max at 230 VAC Power Factor • DRS80 0.6 typical DRS120 & 240 0.95 typical Conforms to EN61000-3-2 Class A. Earth Leakage Current • 1.5 mA maximum Efficiency Isolation Switching Frequency Signals MTBF • See table • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground • DRS80 60-300 kHz variable DRS120 & DRS240 100 kHz typical PFC & main converter • DRS120 & 240: DC OK Volt free contacts • >200 kHrs to MIL HDBK217F Environmental Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • • Ripple & Noise • Overvoltage Protection • Overload Protection • Short Circuit Protection • Temperature • Coefficient See table See table ±1% at 50% load No minimum load required 1 s maximum 20 ms typical 20 ms minimum at full load and 115 VAC ±0.5% ±1% 10% maximum deviation, recovering to less than 1% within 500 µs for 50% step load change at 0.2 A/µs 100 mV pk-pk maximum, measured with 20 MHz BW 12 V output: 16.5-18 V, 24 V output: 29-31.2 V, 48 V output: 57.6-62.4 V 110-150% of rated current, constant current limit Trip and restart (hiccup mode) ±0.02%/°C Operating Temperature Cooling Operating Humidity Storage Temperature Shock Vibration • • • • • -20 ºC to +70 ºC (see derating curves) Natural covection 5-95% RH, non-condensing -25 °C to +85 °C IEC68-2-6, 30 g, 11ms half sine, 3 times in each of 6 axes • IEC68-2-27, 10-500 Hz, 2 g 10 mins/sweep. 60 mins for each of 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity • • • • Radiated Immunity EFT/Burst Surge • • • Conducted Immunity Dips & Interruptions • • Safety Approvals • EN55022, class B conducted & radiated EN61000-3-2, class A EN61000-3-3 EN61000-4-2, 4 KV Contact, 8 KV Air Discharge EN61000-4-3, 3 V/m Perf Criteria A EN61000-4-4, level 2 Perf Criteria A EN61000-4-5, Installation Class 3 Perf Criteria B EN61000-4-6, 3 V Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B UL508, EN60950, UL1604 Pending Output Voltage 12 V 24 V 48 V 12 V 24 V 48 V 12 V 24 V 48 V Output Power 72 W 80 W 80 W 96 W 120 W 120 W 180 W 240 W 240 W Output Voltage Trim 12-15 V 24-28 V 48-56 V 12-15 V 24-28 V 48-56 V 12-15 V 24-28 V 48-56 V Output Current(1) 6.0 A 3.4 A 1.7 A 8.0 A 5.0 A 2.5 A 15.0 A 10.0 A 5.0 A Typical Efficiency(2) 89% 90% 91% 89% 91% 91% 89% 92% 92% Model Number DRS80US12 DRS80US24 DRS80US48 DRS120PS12 DRS120PS24 DRS120PS48 DRS240PS12 DRS240PS24 DRS240PS48 Notes 1. At nominal output voltage. Derate as output voltage increases. 2. At 230 VAC input, 100% load Mechanical Details W W L 1 Pin Connections 1 6 Conn 4 DC Output DC Output DC OK DC OK OVERLOAD OVERLOAD H Sizes (inches/mm) Model W L H Weight lbs (g) Wire sizes AWG (mm2) DRS80 1.26 (32) 4.00 (102) 4.88 (124) 0.92 (420) AWG24-10 (0.2-5.3 mm2) DRS120 1.57 (40) 4.60 (113.3) 4.88 (124) 1.37 (620) AWG24-10 (0.2-5.3 mm2) DRS240 2.36 (60) 4.60 (113.3) 4.88 (124) 1.98 (900) AWG24-10 (0.2-5.3 mm2) 2 Line 3 Ground 6 DC OK* 5 DC OK* 4 Negative 3 Negative 2 Positive 1 Positive * Available on DRS120 and 240, DRS80 has a 4 way output connector AC Input 1 3 Neutral DC Output DRS80 AC Input 1 Designation 1 AC Input H DRS120-240 Pin 3 Derating Curves DRS240 100 100 80 80 60 60 Load (%) Load (%) DRS80 & DRS120 40 20 0 -20 40 20 0 10 20 30 40 50 60 0 -20 70 -10 Ambient Temp (˚C) 0 10 20 30 40 50 60 70 Ambient Temp (˚C) DC OK DCOK Open = Output fail Closed = Output good Available on DRS120 & DRS240 models. Contact Rating: 0.3 A at 60 VDC 500 VDC isolation DCOK 18-Nov-08 AC-DC DRS80-240 Models and Ratings