AC-DC 180 Watts xppower.com AML180 Series • Energy Star Level V • CEC2008 & EISA2007 Compliant • High Power Density • Single Outputs from 18 V to 48 V • High Efficiency • 0 °C to +70 °C Operating Temperature • Non-standard Connectors Available Specification Input General Input Voltage Input Frequency Input Current • 90-264 VAC • 47-63 Hz • 2.5 A rms at 115 VAC, 1.25 A rms at 230 VAC Inrush Current • 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C Power Factor • 0.95 typical Earth Leakage Current • 150 µA max at 115 VAC, 250 µA max at 230 VAC Input Protection • Internal 4 A fuse Standby Power • <0.5 W Consumption Output Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Hold Up Time Line Regulation Load Regulation Transient Response • • • • • • • • • See table Not user-adjustable ±2% maximum at 100% load No minimum load required 3 s maximum at 100 VAC 5 ms minimum at 100 VAC ±0.5% maximum See table 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 2% max pk-pk (see note 1) Overvoltage Protection • 110-140% Vnom, recycle input to reset Overtemperature • Unit shuts down, recycle input to reset Protection Overload Protection • 110-150%, auto recovery Short Circuit Protection • Trip and restart (Hiccup mode) Temperature • 0.04%/°C maximum Coefficient Efficiency Isolation Switching Frequency Power Density MTBF • 87% min • 3000 VAC Input to Output 1500 VAC Input to Ground Output 0 V is electrically connected to Input Earth • 20-80 kHz variable • 5.0 W/In3 • >100 kHrs per MIL-HDBK-217F (+25 °C ambient at full load) Environmental Operating Temperature • 0 °C to 70 °C, derate from 100% power at 40 ºC to 60% power at 70 ºC Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -20 °C to +80 °C Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Magnetic Field Dips & Interruptions Safety Approvals • EN55022/FCC, Class B conducted EN55022/FCC, Class B radiated • EN61000-3-2 • EN61000-3-3 • EN61000-4-2, ±4 kV contact, ±8 kV air discharge Perf Criteria A • EN61000-4-3, 3 V/m Perf Criteria A • EN61000-4-4, level 2 Perf Criteria A • EN61000-4-5, installation class 3 Perf Criteria A • EN61000-4-6, 3 Vrms Perf Criteria A • EN6100-4-8, 1A/m Perf Criteria A • EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • EN60950, UL60950, CSA22.2 No. 60950 per cUL, CE Mark Output Power 180 W 180 W 180 W 180 W Output Voltage 18 V 19 V 24 V 48 V Output Current 10.00 A 9.47 A 7.50 A 3.75 A Model Number (3) AML180PS18 AML180PS19 AML180PS24 AML180PS48 Total Regulation(2) 5% 5% 5% 5% Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 47 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For optional IEC320-C6 input connector, add suffix ‘C6’ to end of part number. Mechanical Details Cable length approx 70.9” ±1.97” (1800mm ±50mm) (4) 1 3 2 4 1.6 Power On Indicator (40.7) Pin 1 2 3 4 Shell Function Output + Output + Return/Input Earth Return/Input Earth Return/Input Earth 6.69 (170) Rubber foot (4 places.) 0.02 (0.5) 3.35 (85.0) AC Input IEC 320/C14 Inlet Notes 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 1.89 lb (860 g). 3. Optional output connectors available. Consult sales. 4. Output connector (Kycon KPP-4P or equivalent) mates with Kycon KPJ-4S or equivalent. 05-Dec-08 AC-DC AML180 Models and Ratings