AC-DC 5-60 Watts xppower.com DNR05-60 Series • Rugged Design for Industrial Applications • Up to 89% Efficiency • Wide Adjustment Range • DC OK 24 V Models • DC Standby Versions • Connector Options • Full Power to +60 ˚C Specification Input General Input Voltage • 90-264 VAC, 120-370 VDC: DNR05/10/18 85-264 VAC, 90-375 VDC: DNR30/60 Input Frequency • 47-63 Hz Inrush Current • 5-18 W: 10/18 A at 115/230 VAC 30 W: 20/40 A at 115/230 VAC 60 W: 30/60 A at 115/230 VAC Power Factor • Meets EN61000-3-2 for class A equipment Earth Leakage Current • 0.8 mA max Output Efficiency Isolation Switching Frequency Signals MTBF Output Voltage Output Voltage Trim Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time • • • • • • • Line Regulation • Load Regulation • Transient Response Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection • • • • • Temperature Coefficient • See tables See tables ±1% No minimum load required <1000 ms <150 ms 5 W: 30/130 ms at 115/230 VAC 10 W: 25/100 ms at 115/230 VAC 18 W: 20/75 ms at 115/230 VAC 30 W: 20/30 ms at 115/230 VAC 60 W: 20/30 ms at 115/230 VAC 5-18 W: ±1.0% max 30-60 W: ±0.5% max 5-18 W: ±2.0% max 30-60 W: ±0.5% max 300 µs for a 50% load change 50 mV pk-pk, 20 MHz BW Output clamps at 120-145% Vnom 105-145% 5-18 W: Trip and restart (Hiccup mode) 30-60 W: Constant power ±0.03%/ºC • See tables • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 100 KHz typical • DC ON indicator LED Green: All models DC LOW indicator LED Red: 5-18 W models DC OK: 24 V 30-60 W models • 200 kHrs typical per MIL-HDBK-217F GF, +40 ºC Environmental Operating Temperature • -10 °C to +70 °C, derate linearly from +50 °C for 5 & 18 W models, +60 °C for all other models (See derating curves) Cooling • Convection-cooled Operating Humidity • 20-95% RH, non-condensing Storage Temperature • -25 ºC to +85 ºC Shock • 4 g, 22 ms, X, Y & Z axis Vibration • 1 g, 10 Hz to 500 kHz, along X, Y & Z axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Dips & Interruptions Safety Approvals EN55022, level B conducted EN61000-3-2, class A EN61000-3-3 amendments 1 & 2 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, level 3 Perf Criteria A EN61000-4-4, level 3 Perf Criteria A EN61000-4-5, level 3 Perf Criteria A EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B • EN60950-1:2001, UL508, UL1310 - see note 3 & ratings table, UL60950-1, cUL60950-1, CE Mark • • • • • • • • Output Voltage 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 15 V 24 V 5V 12 V 24 V 48 V 5V 12 V 24 V 48 V AC-DC DNR05-60 Models and Ratings Output Voltage Trim 4.50-5.75 V 10.80-13.80 V 13.50-17.25 V 21.60-28.80 V 4.50-5.75 V 10.80-13.80 V 13.50-17.25 V 21.60-28.80 V 4.50-5.75 V 10.80-13.80 V 13.50-17.25 V 21.60-28.80 V 5.00-5.50 V 12.00-14.00 V 24.00-28.00 V 48.00-55.00 V 5.00-5.50 V 12.00-14.00 V 24.00-28.00 V 48.00-55.00 V Typical Efficiency 69% 72% 72% 72% 73% 75% 76% 76% 75% 77% 77% 77% 79% 84% 86% 86% 79% 86% 89% 89% Current 1.000 0.420 0.340 0.210 2.000 0.840 0.670 0.420 3.000 1.500 1.200 0.750 6.000 2.500 1.250 0.625 10.000 5.000 2.500 1.250 A A A A A A A A A A A A A A A A A A A A Model Number DNR05US05(1,3) DNR05US12(1,3) DNR05US15(1,3) DNR05US24(1,3) DNR10US05(1,3) DNR10US12(1,3) DNR10US15(1,3) DNR10US24(1,3) DNR18US05(1,3) DNR18US12(1,3) DNR18US15(1,3) DNR18US24(1,3) DNR30US05(1) DNR30US12(1,3) DNR30US24(1,3) DNR30US48(1,3) DNR60US05(1) DNR60US12†(1) DNR60US24†(1,3) DNR60US48†(1,3) Notes 1. Add suffix ‘-S’ for spring clamp option. 2. 30-60 W models are suitable for battery-charging applications. 3. Approved to UL1310. † Available from Farnell. See pages 204-206. Derating Curves DNR5-18 Models DNR 05, 10, 18 100 80 Load (%) Load (%) 80 60 40 20 0 -10 0 10 20 30 40 50 60 70 DNR30-60 Models DNR 30, 60, 120, 240 100 Load (%) 80 60 40 20 60 70 0 -10 60 40 20 Ambient Temp (˚C) DNR10 100 DNR10 DNR05 DNR18 0 10 20 30 40 Ambient Temp (˚C) 50 60 70 0 -10 0 10 AC-DC DNR05-60 Mechanical Details 5/10/18 W Models 0.89 (22.5) 2 4.53 (115.0) 1 DC Output DC LO 3.48 (88.5) ON 1 2 3 AC Input DNR05, 10, 18 Connections Designation Conn Pin 1 Ground AC 2 Neutral Input 3 Line DC 1 Positive 2 Negative Output Notes 1. All dimensions in inches (mm). 2. Weight 0.33 lb (150 g) approx. 30/60 W Models 1.59 (40.5) 4.53 (115.0) 5 4 3 2 1 DC Output 3.60 (90.0) ON 1 2 3 AC Input Notes 1. All dimensions in inches (mm). 2. Weight 0.6 lb (275 g) approx. DNR30/60 Connections Designation Conn Pin 1 Ground AC 2 Neutral Input 3 Line 1 DC OK* 2 Positive DC 3 Positive Output 4 Negative 5 Negative * 24 V & standby models only. + 5 4 3 2 1 DC Output Maximum current drain from battery by PSU when inactive 22 mA. + Relay Control DC OK D1 Fuse Relay Coil LOAD ON DNR30/60 Connections Designation Conn Pin 1 Ground AC 2 Neutral Input 3 Line 1 DC OK* 2 Positive DC 3 Positive Output 4 Negative 5 Negative Battery - 1 2 3 - DNR30/60 connection for DC standby system applications * 24 V & standby models only. Output Set Voltages For Standby Versions Model Voltage Current Efficiency DNR30US12* 13.6 V 2.20 A 84% DNR30US24* 27.2 V 1.10 A 86% DNR30US48* 54.5 V 0.55 A 86% DNR60US12* 13.6 V 4.40 A 86% DNR60US24* 27.2 V 2.20 A 89% DNR60US48* 54.5 V 1.10 A 89% Notes ‘*’ at the end of the part number denotes DC standby system. DC OK 30-60 W Models Output good = 24 V Output not good = 0 V RL > 700ohmRL > 700ohm DCOK DCOK DCOK -Vout -Vout -Vout a) Relay Example a) Relay Example Example using external relay to create volt-free contact 22K DCOK 0.5W 22K 0.5W 5.1K 0.3W -Vout 5.1K 0.3W 5 V Signal Example b) 5 V Signalb) Example Example using external components to create TTL signal Standard on 24 V models, 30-60 W only. DCOK DCOK 09-Oct-07 AC-DC DNR05-60 Standby Versions