XPPOWER DNR10US15

AC-DC
5-60 Watts
xppower.com
DNR05-60 Series
•
Rugged Design for Industrial Applications
•
Up to 89% Efficiency
•
Wide Adjustment Range
•
DC OK 24 V Models
•
DC Standby Versions
•
Connector Options
•
Full Power to +60 ˚C
Specification
Input
General
Input Voltage
• 90-264 VAC, 120-370 VDC: DNR05/10/18
85-264 VAC, 90-375 VDC: DNR30/60
Input Frequency
• 47-63 Hz
Inrush Current
• 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor
• Meets EN61000-3-2 for class A equipment
Earth Leakage Current • 0.8 mA max
Output
Efficiency
Isolation
Switching Frequency
Signals
MTBF
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
•
•
•
•
•
•
•
Line Regulation
•
Load Regulation
•
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
•
•
•
•
•
Temperature
Coefficient
•
See tables
See tables
±1%
No minimum load required
<1000 ms
<150 ms
5 W: 30/130 ms at 115/230 VAC
10 W: 25/100 ms at 115/230 VAC
18 W: 20/75 ms at 115/230 VAC
30 W: 20/30 ms at 115/230 VAC
60 W: 20/30 ms at 115/230 VAC
5-18 W: ±1.0% max
30-60 W: ±0.5% max
5-18 W: ±2.0% max
30-60 W: ±0.5% max
300 µs for a 50% load change
50 mV pk-pk, 20 MHz BW
Output clamps at 120-145% Vnom
105-145%
5-18 W: Trip and restart (Hiccup mode)
30-60 W: Constant power
±0.03%/ºC
• See tables
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 KHz typical
• DC ON indicator LED Green: All models
DC LOW indicator LED Red:
5-18 W models
DC OK: 24 V 30-60 W models
• 200 kHrs typical per MIL-HDBK-217F
GF, +40 ºC
Environmental
Operating Temperature • -10 °C to +70 °C, derate linearly from
+50 °C for 5 & 18 W models, +60 °C for
all other models (See derating curves)
Cooling
• Convection-cooled
Operating Humidity
• 20-95% RH, non-condensing
Storage Temperature
• -25 ºC to +85 ºC
Shock
• 4 g, 22 ms, X, Y & Z axis
Vibration
• 1 g, 10 Hz to 500 kHz, along X, Y & Z axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Dips & Interruptions
Safety Approvals
EN55022, level B conducted
EN61000-3-2, class A
EN61000-3-3 amendments 1 & 2
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, level 3 Perf Criteria A
EN61000-4-4, level 3 Perf Criteria A
EN61000-4-5, level 3 Perf Criteria A
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
• EN60950-1:2001, UL508,
UL1310 - see note 3 & ratings table,
UL60950-1, cUL60950-1, CE Mark
•
•
•
•
•
•
•
•
Output
Voltage
5V
12 V
15 V
24 V
5V
12 V
15 V
24 V
5V
12 V
15 V
24 V
5V
12 V
24 V
48 V
5V
12 V
24 V
48 V
AC-DC
DNR05-60
Models and Ratings
Output
Voltage Trim
4.50-5.75 V
10.80-13.80 V
13.50-17.25 V
21.60-28.80 V
4.50-5.75 V
10.80-13.80 V
13.50-17.25 V
21.60-28.80 V
4.50-5.75 V
10.80-13.80 V
13.50-17.25 V
21.60-28.80 V
5.00-5.50 V
12.00-14.00 V
24.00-28.00 V
48.00-55.00 V
5.00-5.50 V
12.00-14.00 V
24.00-28.00 V
48.00-55.00 V
Typical
Efficiency
69%
72%
72%
72%
73%
75%
76%
76%
75%
77%
77%
77%
79%
84%
86%
86%
79%
86%
89%
89%
Current
1.000
0.420
0.340
0.210
2.000
0.840
0.670
0.420
3.000
1.500
1.200
0.750
6.000
2.500
1.250
0.625
10.000
5.000
2.500
1.250
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Model
Number
DNR05US05(1,3)
DNR05US12(1,3)
DNR05US15(1,3)
DNR05US24(1,3)
DNR10US05(1,3)
DNR10US12(1,3)
DNR10US15(1,3)
DNR10US24(1,3)
DNR18US05(1,3)
DNR18US12(1,3)
DNR18US15(1,3)
DNR18US24(1,3)
DNR30US05(1)
DNR30US12(1,3)
DNR30US24(1,3)
DNR30US48(1,3)
DNR60US05(1)
DNR60US12†(1)
DNR60US24†(1,3)
DNR60US48†(1,3)
Notes
1. Add suffix ‘-S’ for spring clamp option.
2. 30-60 W models are suitable for battery-charging applications.
3. Approved to UL1310.
† Available from Farnell. See pages 204-206.
Derating Curves
DNR5-18 Models
DNR 05, 10, 18
100
80
Load (%)
Load (%)
80
60
40
20
0
-10
0
10
20
30
40
50
60
70
DNR30-60 Models
DNR 30, 60, 120, 240
100
Load (%)
80
60
40
20
60
70
0
-10
60
40
20
Ambient Temp (˚C)
DNR10
100
DNR10
DNR05
DNR18
0
10
20
30
40
Ambient Temp (˚C)
50
60
70
0
-10
0
10
AC-DC
DNR05-60
Mechanical Details
5/10/18 W Models
0.89
(22.5)
2
4.53 (115.0)
1
DC Output
DC LO
3.48
(88.5)
ON
1
2
3
AC Input
DNR05, 10, 18 Connections
Designation
Conn
Pin
1
Ground
AC
2
Neutral
Input
3
Line
DC
1
Positive
2
Negative
Output
Notes
1. All dimensions in inches (mm).
2. Weight 0.33 lb (150 g) approx.
30/60 W Models
1.59
(40.5)
4.53 (115.0)
5 4 3 2 1
DC Output
3.60
(90.0)
ON
1
2
3
AC Input
Notes
1. All dimensions in inches (mm).
2. Weight 0.6 lb (275 g) approx.
DNR30/60 Connections
Designation
Conn
Pin
1
Ground
AC
2
Neutral
Input
3
Line
1
DC OK*
2
Positive
DC
3
Positive
Output
4
Negative
5
Negative
* 24 V & standby models only.
+
5 4 3 2 1
DC Output
Maximum current drain from
battery by PSU when inactive
22 mA.
+
Relay
Control
DC OK
D1
Fuse
Relay
Coil
LOAD
ON
DNR30/60 Connections
Designation
Conn
Pin
1
Ground
AC
2
Neutral
Input
3
Line
1
DC OK*
2
Positive
DC
3
Positive
Output
4
Negative
5
Negative
Battery
-
1
2
3
-
DNR30/60 connection for DC standby system applications
* 24 V & standby models only.
Output Set Voltages For Standby Versions
Model
Voltage
Current
Efficiency
DNR30US12*
13.6 V
2.20 A
84%
DNR30US24*
27.2 V
1.10 A
86%
DNR30US48*
54.5 V
0.55 A
86%
DNR60US12*
13.6 V
4.40 A
86%
DNR60US24*
27.2 V
2.20 A
89%
DNR60US48*
54.5 V
1.10 A
89%
Notes
‘*’ at the end of the part number denotes DC standby system.
DC OK
30-60 W Models
Output good = 24 V
Output not good = 0 V
RL > 700ohmRL > 700ohm
DCOK
DCOK
DCOK
-Vout
-Vout
-Vout
a) Relay Example
a) Relay Example
Example using external relay
to create volt-free contact
22K
DCOK
0.5W
22K
0.5W
5.1K
0.3W
-Vout
5.1K
0.3W
5 V Signal Example
b) 5 V Signalb)
Example
Example using external components
to create TTL signal
Standard on 24 V models, 30-60 W only.
DCOK
DCOK
09-Oct-07
AC-DC
DNR05-60
Standby Versions