here

DRAN30/60 SERIES
AC - DC DIN RAIL MOUNTABLE POWER SUPPLY
INDUSTRIAL CONTROL EQUIPMENT
FEATURES
‧UNIVERSAL INPUT 85~264VAC
‧SHORT CIRCUIT PROTECTION
‧INTERNAL INPUT FILTER
‧3 YEARS WARRANTY
R
R
R
HH H
UL 1310
Class I, Div 2
EN 61558-1
EN 61558-2-16
a
UL 60950-1
IND. CONT. EQ.
UL 508
EN 60950-1
MODEL LIST
DRAN 60- 24 x
Wattage
05 : 05V OUT 24 : 24V OUT
12 : 12V OUT 48 : 48V OUT
BLANK : SPRING TERMINAL TYPE
A : SCREW TERMINAL TYPE
MODEL LIST
MODEL NO.
INPUT
VOLTAGE
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT
EFF.
(min.)
EFF.
(typ.)
Single Output Models
DRAN30-05(A)
85~264 VAC
30 WATTS
+ 5 VDC
6A
77%
79%
DRAN30-12(A)
85~264 VAC
30 WATTS
+ 12 VDC
2.5 A
82%
84%
DRAN30-24(A)
85~264 VAC
30 WATTS
+ 24 VDC
1.25 A
83%
86%
DRAN30-48(A)
85~264 VAC
30 WATTS
+ 48 VDC
0.625A
83%
86%
DRAN60-05(A)
85~264 VAC
50 WATTS
+ 5 VDC
10 A
77%
79%
DRAN60-12(A)
85~264 VAC
60 WATTS
+ 12 VDC
5A
84%
86%
DRAN60-24(A)
85~264 VAC
60 WATTS
+ 24 VDC
2.5 A
86%
89%
DRAN60-48(A)
85~264 VAC
60 WATTS
+ 48 VDC
1.25 A
86%
89%
max.
max.
unit
unit
135
KHz
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
GENERAL
Conditions
Conditions
Characteristics
min.
min.
typ.
typ.
Switching frequency
Vi nom, Io nom
Isolation voltage
Input-Output
3,000 / 4,242
VAC / VDC
Input-FG
1,500 / 2,121
VAC / VDC
500 / 710
VAC / VDC
55
Output-FG
Isolation resistance
Input-Output, @ 500VDC
100
Ambient temperature
Operating at Vi nom
-40
o
o
MΩ
+ 71
o
C
% / oC
Derating (see derating curve)
Vi nom, from +61 C to +71 C
Storage temperature
Non operational
-40
+ 85
Relative humidity
Vi nom, Io nom
20
95
% RH
Temperature coefficient
Vi nom, Io min
± 0.03
% / oC
www.chinfa.com
2015.05.12
2.5
o
C
[email protected]
P1
DRAN30/60 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
GENERAL
Conditions
Conditions
Characteristics
MTBF
min.
min.
DRAN30
Bellcore Issue 6 @40oC, GB
DRAN60
Bellcore Issue 6 @40oC, GB
Altitude during operation
Dimension
Cooling
Installation position
max.
max.
typ.
unit
unit
5V
12V
612,000
640,000
Hours
Hours
24V
665,000
Hours
48V
5V
675,000
Hours
532,000
Hours
12V
556,000
Hours
24V
580,000
Hours
48V
596,000
EN 60950-1
Spring & Screw terminal type
5,000
Hours
m
mm
L90 x W40.5 x D114
Free air convection
Vertical ( other direction may derating using )
Pollution degree
2
INPUT SPECIFICATIONS
Characteristics
Rated input voltage
Absolute input max. range
Input current
max.
unit
VAC
100
240
85
264
VAC
90
375
VDC
Vi : 115 / 230 VAC, Io nom
DC in
DRAN30
Vi : 115 / 230 VAC, Io nom
DRAN60
Vi : 85 VAC, Io nom
Line frequency
Vi nom, Io nom
Inrush current
Vi : 115 / 230 VAC , Io nom
Leakage current
typ.
AC in
Io nom
Ta min ... Ta max,
Io nom
Rated input current
Power dissipation
min.
Conditions
560 / 330
mA
1,060 / 590
DRAN30 / 60
mA
800 / 1,500
mA
Hz
DRAN30
63
20 / 40
DRAN60
30 / 60
47
DRAN30 / DRAN60 series
Vi : 230 VAC, Io nom
A
A
5V
8.5 / 12.5
W
12V
24V
5.6 / 9.0
W
5.5 / 8.8
W
48V
4.9 / 7.8
W
Input-Output
0.25
mA
Input-FG
3.5
mA
max.
unit
+1
%
OUTPUT SPECIFICATIONS
Characteristics
Conditions
min.
Output voltage accuracy
(Adjusted before shipment)
Vi nom, Io max
0
Minimum load
Line regulation
Vi nom
Io nom, Vi min ...Vi max
0
Load regulation
Vi nom, Io min ...Io nom
Voltage trim range
DRAN30 & DRAN60 series
Vi nom, 0.8 Io nom
Rated continuous loading
%
± 0.5
5.5
VDC
%
5
12V
24V
12
14
VDC
24
28
VDC
48
DRAN30 series
48V
5V
Vi nom
12V
2.5 A @ 12Vdc / 2.1 A @ 14 Vdc
24V
1.25 A @ 24Vdc / 1.05 A @ 28 Vdc
48V
0.625 A @ 48Vdc / 0.54 A @ 55 Vdc
Vi nom
Hold up time
Vi : 115 / 230 VAC , Io nom
Turn on time
Vi nom, Io nom
Vi nom, Io nom
2015.05.12
%
± 0.5
5V
DRAN60 series
www.chinfa.com
typ.
with Capacitor load
55
6 A @ 5Vdc / 5.4 A @ 5.5 Vdc
5V
10 A @ 5Vdc / 9.0 A @ 5.5 Vdc
12V
5 A @ 12Vdc / 4.25 A @ 14 Vdc
24V
2.5 A @ 24Vdc / 2.1 A @ 28 Vdc
48V
1.25 A @ 48Vdc / 1.08 A @ 55 Vdc
VDC
2,000
ms
ms
2,000
ms
20 / 30
[email protected]
P2
DRAN30/60 SERIES
SPECIFICATION
All Specifications Typical At Nominal Line, Full Load, 25oC Unless Otherwise Noticed
OUTPUT SPECIFICATIONS
Characteristics
Rise time
Conditions
Vi nom, Io nom
Vi nom, Io nom
min.
typ.
max.
with Capacitor load
unit
ms
150
ms
500
Fall time
Transient recovery time
Vi nom, Io nom
150
ms
Vi nom, 1~0.5 Io nom
Ripple & noise
Vi nom, Io nom, BW = 20MHz
2
50
mV
Power back immunity
DRAN30 & DRAN60
Vi nom, Io nom
1 second
Capacitor load
Vi nom, Io nom
DC ON indicator threshold
at start up (Green LED)
Vi nom, Io nom
Efficiency
ms
5V
7.5
VDC
12V
24V
18
VDC
35
VDC
48V
63
DRAN30 / 60
5V
3,500 / 7,000
VDC
μF
3.5
4.5
VDC
12V
24V
9.0
10.8
VDC
18
21.6
VDC
48V
VDC
37
43
Up to 89%, See model list and typ efficiency curve
Vi nom, Io nom, Po / Pi
CONTROL AND PROTECTION
Characteristics
Conditions
min.
typ.
Input fuse
Internal surge voltage protection
Rated over load protection
Power Rdy (for 24V model only)
Over voltage protection
max.
unit
T2A / 250VAC internal
Varistor
IEC 61000-4-5
Vi nom (see typ current limited curve)
110
150
%
Threshold voltage of contact closed (at start up)
18.8
19.6
VDC
Vi nom, 0.8 Io nom (Auto Recovery)
5V
6.0
6.8
VDC
12V
15
16.5
VDC
24V
30
33
VDC
48V
60
66
VDC
Output short circuit
Fold forward
Degree of protection
IP20
APPROVALS AND STANDARDS
UL / cUL
UL 508 Listed
UL 60950-1, UL 1310 Class 2 Power (only 5V and DRAN60-12(A) w/o Class 2) Recognized
ISA 12.12.01(Class I, Division 2, Groups A, B, C and D)
TUV
EN 60950-1
EN 61558-1, EN 61558-2-16 (meet EN 60204-1)
CE
EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3
EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3
EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4
EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11
ENV 50204 Level 2, EN 61204-3
CCC
GB4943.1, GB9254, GB17625.1
Vibration resistance
meet IEC 60068-2-6 (Mounting on rail : 10-500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis )
Shock resistance
meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face)
PHYSICAL CHARACTERISTICS
Case size
90 x 40.5 x 114 mm (3.6 x 1.59 x 4.49 inches)
Case material
Plastic
Weight
DRAN30 : 270 g
Packing
DRAN30 : 0.35 kg ; 40
www.chinfa.com
2015.05.12
DRAN60 : 340 g
/ 15 kg / 2.16 CUFT
DRAN60 : 0.41 kg ; 40
/ 17.5 kg / 2.16 CUFT
[email protected]
P3
DRAN30/60 SERIES
MECHANISM & PIN CONFIGURATION
CONSTRUCTION
40.50 [1.59]
40.50 [1.59]
54321
54321
--
--
++ Rdy
Vout ADJ.
90.00 [3.60]
90.00 [3.60]
mm [inch]
DC ON
114.00 [4.49]
INSTALLATION
Ventilation / Cooling
Normal convection
All sides 25mm free space
For cooling recommended
Connector size range
Spring terminal:
AWG24-14 (0.2~2mm2 ) flexible / solid cable,
10 m/m stripping at cable end recommends
Screw terminal:
AWG26-12 (0.2~2.5mm2 ) flexible / solid cable,
connector can withstand torque at maximum 5
pound-inches.
4-5 m/m stripping at cable end recommends
Use copper conductors only, 60 / 75oC
++ Rdy
Vout ADJ.
DC ON
N L
N L
6 7 8
6 7 8
Easy snap-on mounting onto the DIN-Rail
(TS35/7.5 or TS35/15), unit sits safeIy and
firmly on the rail.
GENERAL TOLERANCE
0.00[0.00] - 30.00[1.18]
±0.30[0.01]
30.00[1.18] - 120.00[4.72]
±0.50[0.02]
PIN ASSIGNMENT
Designation
PIN NO.
1
OUT
2
3
4
5
Description
RDY
+
DC OK output for relay (not connect except 24V model)
+
-
Positive output terminal
-
Negative output terminal
Positive output terminal
Negative output terminal
Ground this terminal to minimize high-frequency emissions
IN
6
7
OTHER
8
N
Input terminals (neutral conductor, no polarity at DC input)
L
Vout ADJ.
Input terminals (phase conductor, no polarity at DC input)
DC ON
Operation indicator LED
Trimmer-potentiometer for Vout adjustment
Fig. 1 Rdy connection
RL > 700ohm
Rdy
2.2K
0.5W
Rdy
- Vout
5.1V
0.3W
- Vout
b ) 5V signal
a ) Relay
CIRCUIT SCHEMATIC
‧Block diagram
L
Fuse
Line
Filter
N
Inrush Current
Switching
Limiter and
Device
Rectifier
PWM
Controller
Y
Y
Y
Vo +
Rectifier
Vo -
Opto Isolation
Reference &
Error Amp.
Opto Isolation
Over Voltage
Detection
Output Level
Detection
Vout
ADJ.
DC ON
(Green LED)
1)
RDY
(Open Collector)
Note: 1) for 24V Model Only
www.chinfa.com
2015.05.12
[email protected]
P4
DRAN30/60 SERIES
TYP. CURRENT LIMITED CURVE
Output Voltage [ % ]
DRAN30-24(A)
100
75
230 Vac
115 Vac
50
25
0
120
130
140
150
160
170
180
190
Output Current [ % ]
Output Voltage [ % ]
DRAN60-24(A)
100
75
230 Vac
115 Vac
50
25
0
110
120
130
140
150
160
170
180
190
Output Current [ % ]
DERATING CURVE
Power out [ % ]
100
75
Safe Operating Area
0
-40
o
61
71
Temperature [ C ]
TYP. EFFICIENCY CURVE
95
90
85
80
75
70
65
60
55
50
45
40
10
www.chinfa.com
2015.05.12
DRAN60-24(A)
EFFICIENCY [ % ]
EFFICIENCY [ % ]
DRAN30-24(A)
230 Vac
115 Vac
25
50
Power out [ % ]
75
100
95
90
85
80
75
70
65
60
55
50
45
40
10
230 Vac
115 Vac
25
50
Power out [ % ]
75
100
[email protected]