XPPOWER DNR240TS24-I

AC-DC
120-240 Watts
xppower.com
DNR120-240TS Series
•
Rugged Design for Industrial Applications
•
Up to 88% Typical Efficiency
•
Wide Adjustment Range
•
Full Power to 60 ºC
•
Three Phase Operation
•
Single Phase Operation
•
-25 ºC to 70 ºC Operation
Specification
Input
General
Input Voltage
• 340-575 VAC 3Ø (1Ø to 1Ø operation with
75% output derating), 480-820 VDC
Input Frequency
• 47-63 Hz
Input Current
• DNR120TS: 0.35 A at 500 VAC
DNR240TS: 0.70 A at 500 VAC
Inrush Current
• 120 W 15 A typical at 500 VAC, cold start
240 W 20 A typical at 500 VAC, cold start
Power Factor
• 0.6 at 500 VAC input and nominal load
Earth Leakage Current • 0.32 mA
Efficiency
Isolation
Switching Frequency
Signals
MTBF
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
•
•
•
•
•
•
•
•
•
•
Ripple & Noise
Overvoltage Protection
Overload Protection
Temperature
Coefficient
Current Share
•
•
•
•
See table
See table
±1%
No minimum load required
<1000 ms
<150 ms
20 ms min at 400 VAC
±1%
±1% (±5% for units in parallel)
4% max deviation recovering to within
1% in 1 ms for 50% load change
100 mV pk-pk 20 MHz BW
120-145%, recycle input to reset
Continuous current limit
±0.02%/°C
• 2 units can be connected in parallel,
DNR240TS only, total output derates
by 10%
• See table
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• DNR120TS: 65 kHz typical
DNR240TS: 25 kHz typical
• DC ON indicator LED Green,
DC LOW indicator LED Red
DC OK: normally open relay on
24 V models
• 210 kHrs to MIL-STD 217 F
Environmental
Operating Temperature • -25 ºC to 70 ºC, derate linearly from 60 ºC
at 3.5%/ºC (see derating curve)
Cooling
• Convection-cooled
Operating Humidity
• 20-95% RH, non-condensing
Storage Temperature
• -25 °C to +85 °C
Shock
• 4 g peak, 22 ms on X, Y and Z axis
Vibration
• 10 to 500 Hz, 1 g rms on X, Y and Z axis
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
•
•
•
•
•
•
•
•
•
•
EN55022, class B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2, level 4 perf criteria A
EN61000-4-3, level 3 perf criteria A
EN61000-4-4, level 4 perf criteria A
EN61000-4-5, level 3 perf criteria B
EN61000-4-6, level 3 perf criteria A
EN61000-4-8, level 4 perf criteria A
EN61000-4-11, 30% 500 ms,
60% 200 ms, 100% 5000 ms
Perf Criteria A, A, A
• EN60950-1:2001, UL508, UL60950-1
Output Voltage
12 V
24 V
24 V
48 V
AC-DC
DNR120-240TS
Models and Ratings
Output Voltage Trim
11.4-14.5 V
22.5-28.5 V
22.5-28.5 V
47.0-56.0 V
Output Current(1)
10.0 A
5.0 A
10.0 A
5.0 A
Typical Efficiency
87%
88%
87%
88%
Model Number
DNR120TS12
DNR120TS24
DNR240TS24-I
DNR240TS48-I
Notes
1. Reduce by 25% for single phase input operation.
Mechanical Details
0.3
(7.0)
4.39 (111.3)
6
1
DC LO
ON
DNR120TS
DNR240TS
4.87
(123.6)
4.87
(123.6)
DC LO
ON
Single
Parallel
1
4
1
4
AC Input
AC Input
2.93 (74.3)
4
1
5
6
DC Output
3.50 (89.0)
DC OK signal connector on underside
Notes
1. All dimensions in inches (mm).
2. Weight - DNR120TS: 1.76 lb (800 g) approx.
DNR240TS: 2.43 lb (1100 g) approx.
3. Screw terminal: 10-24 AWG cable size.
DC OK signal connector: 10-24 AWG cable
4. DC OK Relay 60 VDC at 300 mA
5. Allow 0.98” (25 mm) clearance all round for cooling
Pin Connections - AC Input
Pin
Designation
1
Ground
2
L1
3
L2
4
L3
Pin
1
2
3
4
5
6
Pin Connections - DC Output
Designation
-V
-V
+V
+V
DC OK*
DC OK*
* Available on 24 V versions.
Derating Curves
DNR120-240TS
Load (%)
100
75
0
-25
60
70
Ambient Temp (˚C)
18-Nov-08