XPPOWER THF75US12

45-480 Watts
xppower.com
THF Series
•
Wide Adjustment Range
•
Rugged for Industrial Use
•
High Efficiency
•
Overvoltage Protection
•
Overcurrent Protection
•
Overtemperature Protection
•
Lightweight Design
Specification
Input
General
Input Voltage
• 90-264 VAC except:
90-132/176-264 VAC switch-selectable
(THF120 and THF480LSxx models) and
180-264 VAC (THF480PS models)
Input Frequency
• 47-63 Hz
Input Current
• 0.5 A at 230 VAC 45 W models,
0.8 A at 230 VAC 75 W models,
1.4 A at 230 VAC 120 W models,
1.8 A at 230 VAC 240 W models,
4.0 A at 230 VAC 480 W models
Inrush Current
• 60 A max
Power Factor
• All units EN61000-3-2 compliant,
≥0.95 THF240, ≥0.70 THF480
Earth Leakage Current • <1.0 mA max 45 and 75 W models,
<3.5 mA max 120, 240 & 480 W models
at 240 VAC
Output
Switching Frequency
•
•
•
•
Start Up Rise Time
•
Hold Up Time
•
Line Regulation
•
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
•
•
•
•
Temperature
Coefficient
•
See tables
±10%
±2% max
800 ms max 45 and 240 W models,
1000 ms 75 W models,
500 ms 120 W models,
1200 ms 480 W models
60 ms max 45 & 75 W models,
70 ms max 120 W models,
40 ms max 240 W & 480 W models
50 ms at 230 VAC 45 & 75 W models,
30 ms at 230 VAC 120 W models,
20 ms at 230 VAC max 240 W models,
16 ms at 230 VAC max 480 W models
±1.0% max 45 W models,
±0.5% 75, 120, 240 & 480 W models
±0.5% max, ±1% max 45 W models
See tables
115-135%
105-150%, constant current with auto
recovery
0.03% /˚C
• 72-89% (see tables)
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 100 kHz typical 45 & 240 W models
70 kHz typical 480 W models
50 kHz typical 75 & 120 W models
Environmental
Operating Temperature
Operating Humidity
Storage Temperature
Vibration
•
•
•
•
See derating curves
90% RH, non-condensing
-20 ˚C to +85 ˚C
2 G, 10 Hz to 500 kHz, 10 min/cycle for 60
minutes each axis
EMC & Safety
Emissions
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Start Up Delay
1
Efficiency
Isolation
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Safety Approvals
• EN55022/55011, Class B conducted
and radiated, EN61000-3-2, 3
• EN61000-3-3
• EN61000-4-2, level 3 air, Perf Criteria B
• EN61000-4-3, 10 V/m, Perf Criteria B
• EN61000-4-4, level 3, Perf Criteria B
• EN61000-4-5, level 3, Perf Criteria B
• EN61000-4-6, 10 V rms, Perf Criteria B
• EN60950, UL508,
(UL60950 on 120, 240 & 480 W models)
THF
Models and Ratings
Maximum
Output Power
25 W
42 W
42 W
48 W
Output Voltage
Nominal
5.0 V
12.0 V
15.0 V
24.0 V
Output Voltage
Adjustment
4.75-5.50 V
10.80-12.20 V
13.50-16.50 V
21.60-26.40 V
Output Current
Maximum
5.0 A
3.5 A
2.8 A
2.0 A
Ripple and
Noise(1)
100 mV
200 mV
240 mV
480 mV
Efficiency
72%
77%
77%
80%
Model
Number
THF45US05
THF45US12
THF45US15
THF45US24
Notes
1. Measured at 20 MHz bandwidth using a 12’’ twisted pair terminated with a 0.1 µF/47 µF capacitor.
Mechanical Details
THF45 MODELS
PINOUT
Pin
Function
1
AC Input
2
AC Input
3
Earth
4
DC Output -V
5
DC Output -V
6 DC Output +V
7 DC Output +V
8
LED
9
+V Adj
Weight 0.40 kg
Derating Curve
NB: The THF45 will operate at
full load from 85-264 VAC
input.
2
THF
Models and Ratings
Maximum
Output Power
76 W
77 W
77 W
120 W
120 W
120 W
Output Voltage
Nominal
12.0 V
24.0 V
48.0 V
12.0 V
24.0 V
48.0 V
Output Voltage
Adjustment
12.00-14.00 V
24.00-27.00 V
48.00-53.00 V
12.00-14.00 V
24.00-28.00 V
48.00-53.00 V
Ripple and
Noise(1)
100 mV
150 mV
240 mV
80 mV
80 mV
100 mV
Output Current
Maximum
6.3 A
3.2 A
1.6 A
10.0 A
5.0 A
2.5 A
Efficiency
76%
80%
81%
80%
84%
85%
Notes
1. Measured at 20 MHz bandwidth using a 12” twisted pair terminated with a 0.1 µF/47 µF capacitor.
Mechanical Details
THF120 MODELS
THF75 MODELS
Weight:
THF75 0.55 kg
THF120 0.65 kg
Derating Curves
THF75 MODELS
3
THF120 MODELS
Model
Number
THF75US12
THF75US24
THF75US48
THF120LS12
THF120LS24
THF120LS48
THF
Models and Ratings
Maximum
Output Power
240 W
240 W
480 W
480 W
480 W
480 W
Output Voltage
Nominal
24.0 V
48.0 V
24.0 V
48.0 V
24.0 V
48.0 V
Output Voltage
Adjustment
24.00-28.00 V
48.00-53.00 V
24.00-28.00 V
48.00-53.00 V
24.00-28.00 V
48.00-53.00 V
Output Current
Maximum
10.0 A
5.0 A
20.0 A
10.0 A
20.0 A
10.0 A
Ripple and
Noise(1)
80 mV
150 mV
240 mV
480 mV
240 mV
480 mV
Efficiency
84%
85%
89%
89%
89%
89%
Model
Number
THF240PS24
THF240PS48
THF480LS24
THF480LS48
THF480PS24
THF480PS48
Notes
1. Measured at 20 MHz bandwidth using a 12” twisted pair terminated with a 0.1 µF/47 µF capacitor.
Mechanical Details
THF240 MODELS
THF480 MODELS
Derating Curves
THF240 MODELS
THF480PSXX MODELS
THF480LSXX MODELS
4