R2
Contacts
Miniature plug-in power relays
• WT - standard plug-in version with indicating flag and manual testing/latching lever
• Miniature size
• Cadmium - free contacts available
• Coil AC and DC
• Plug-in version - rail mount TH35, EN 50022
• Plug-in, solder, PCB versions available
• General purpose relays
Contact number & arrangement
Contact material
Voltage
Max. switching voltage AC/DC
Min. switching voltage
Current
Rated load
2C/O
AgCdO, AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm
250 V / 250 V
5 V (AgCdO)
5 V (AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm)
AC1
DC1
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
AC1
Min. breaking capacity
Resistance
Max. operating frequency
• at rated load
• no load
AC1
12 A / 250 V AC - plug-in version
10 A / 250 V AC - PCB version
12 A / 24 V DC - plug-in version
10 A / 250 V DC - PCB version
5 mA (AgNi, AgNi/Au 0,2 µm); 50 mA (AgCdO)
1 mA (AgNi/Au 5 µm)
24 A
12 A - plug-in version
10 A - PCB version
3 000 VA - plug-in version
2 500 VA - PCB version
0,1 W (AgNi/Au 5 µm); 0,3 W (AgNi, AgNi/Au 0,2 µm)
0,5 W (AgCdO)
£ 100 mW
at 100 mA, 24 V
1 200 cycles/hour
18 000 cycles/hour
Coil
Voltage
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
5...220 V DC
6...240 V AC 50 Hz
³ 0,1 Un DC; ³ 0,2 Un AC
see Tables 1, 2
0,9 W DC; 1,6 VA AC
Insulation
Insulation category
Voltage
Insulation rated voltage
Dielectric strength
• coil-contact
• contact-contact
• pole-pole
Contact-coil distance
• clearance
• creepage
C250
250 V AC
2 500 V AC
1 500 V AC
2 500 V AC
³ 2,5 mm
³ 4 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive
• cos j
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storing
• operating
Cover protection category
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
Approvals
1
10 ms AC; 13 ms DC
8 ms AC; 3 ms DC
at 12 A, 250 V AC
³ 10 5
see Fig. 2
³ 2 x10 7
27,5 x 21,2 x 35,6 mm - plug-in standard version (WT)
27,5 x 21,2 x 33 mm - PCB version
and version with threaded bolt
35 g
-40...+85 °C
AC: -40...+55 °C; DC: -40...+70 °C
IP 40
10 g (NO); 5 g (NC)
5g
for 10...150 Hz
max. 270 °C
max. 5 s
B, cUL, UL, VDE, GOST
2
R2
Miniature plug-in power relays
Coil data - DC version
Coil code
Table 1
Rated voltage
V DC
1005
1006
1012
1024
1048
1060
1080
1110
1125
1220
5
6
12
24
48
60
80
110
125
220
Coil operating range
V DC
Coil resistance
(±10%) at 20 °C
W
max. (at 55 °C)
min. (at 20 °C)
4,0
4,8
9,6
19,2
38,4
48,0
64,0
88,0
100,0
176,0
28
40
160
640
2 600
4 000
7 100
13 600
16 000
54 000
5,5
6,6
13,2
26,4
52,8
66,0
88,0
121,0
137,5
242,0
Coil data - AC 50 Hz version
Table 2
Coil operating range
V AC
min. (at 20 °C)
6
12
24
42
48
60
80
110
120
127
220
230/240
Electrical life at AC resistive load
Fig. 1
6,6
13,2
26,4
46,2
52,8
66,0
88,0
121,0
132,0
139,0
242,0
253,0
4,8
9,6
19,2
33,6
38,4
48,0
64,0
88,0
96,0
101,6
176,0
184,0
12
50
190
565
785
1 240
2 190
3 880
4 150
4 940
16 300
17 400
Electrical life reduction factor
at AC inductive load
Fig. 2
F
1
0,8
0,6
Reduction factor
3006
3012
3024
3042
3048
3060
3080
3110
3120
3127
3220
3230
max. (at 55 °C)
0,4
1 0,8
3
0,6
0,4
cosj
Power factor
0,2
R2
3
Miniature plug-in power relays
Maximum DC resistive load
breaking capacity
Fig. 3
Connections diagram (pin side view)
50
12
10
12 (1)
42 (4)
14 (5)
44 (8)
11 (9)
41 (12)
A1 (13)
A2 (14)
5
2
1
0,5
Terminal (pin)
12(1); 42(4); 14(5); 44(8); 11(9); 41(12);
A1(13); A2(14)
mm
0,1
10
0,5 x 1,0
for relays f 1,3 mm ± 0,1
for sockets f 1,5 mm ± 0,1
Drilling hole
20
30
40 50
100
200
300
Dimensions - version with threaded bolt
(without WT)
Dimensions - plug-in version (WT),
with manual testing/latching lever
21,1
21,2
33
6,6 6,6
21,2
6,5
6,3
6,5
6
35,6
6,2 6,3 6,3 4,1
27,5
27,4
27,5
M2,5
6,8
Dimensions - version with cover equipped
with mounting flange (without WT)
43
8
3,5
38
28,4
6,5
33
2
22
Dimensions - PCB version
(without WT)
4
R2
Miniature plug-in power relays
Mounting
Relays R2 are designed for:
• screw terminals sockets GZT2 (modules and clips available) and GZR2 - for DIN rail mounting,
• PCB terminals sockets SU4/2D - for PCB mounting,,
• solder terminals sockets SU4/2L and G4/2,
• direct PCB mounting.
Ordering codes
10 - AgCdO
20 - AgNi
21 AgNi/Au 0,2 µm
23 - AgNi/Au 5 µm
See Tables 1, 2, page 2
2C/O
*
- - -- LDLD WT WTL WTD WTLD -
no additional features
LED indicator
arc suppressing diode
LED indicator +arc suppressing diode
indicating flag + manual testing/latching lever (standard)
indicating flag + manual testing/latching lever + LED indicator
indicating flag + manual testing/latching lever + arc suppressing diode
indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode
* D, LD, WTD, WTLD - only for DC coils
WT - standard features plug-in power relays
2002-12-20