R2 Contacts Miniature plug-in power relays • WT - standard plug-in version with indicating flag and manual testing/latching lever • Miniature size • Cadmium - free contacts available • Coil AC and DC • Plug-in version - rail mount TH35, EN 50022 • Plug-in, solder, PCB versions available • General purpose relays Contact number & arrangement Contact material Voltage Max. switching voltage AC/DC Min. switching voltage Current Rated load 2C/O AgCdO, AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm 250 V / 250 V 5 V (AgCdO) 5 V (AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm) AC1 DC1 Min. switching current Max. inrush current Rated current Max. breaking capacity AC1 Min. breaking capacity Resistance Max. operating frequency • at rated load • no load AC1 12 A / 250 V AC - plug-in version 10 A / 250 V AC - PCB version 12 A / 24 V DC - plug-in version 10 A / 250 V DC - PCB version 5 mA (AgNi, AgNi/Au 0,2 µm); 50 mA (AgCdO) 1 mA (AgNi/Au 5 µm) 24 A 12 A - plug-in version 10 A - PCB version 3 000 VA - plug-in version 2 500 VA - PCB version 0,1 W (AgNi/Au 5 µm); 0,3 W (AgNi, AgNi/Au 0,2 µm) 0,5 W (AgCdO) £ 100 mW at 100 mA, 24 V 1 200 cycles/hour 18 000 cycles/hour Coil Voltage Rated voltage Must release voltage Operating range of supply voltage Rated power consumption 5...220 V DC 6...240 V AC 50 Hz ³ 0,1 Un DC; ³ 0,2 Un AC see Tables 1, 2 0,9 W DC; 1,6 VA AC Insulation Insulation category Voltage Insulation rated voltage Dielectric strength • coil-contact • contact-contact • pole-pole Contact-coil distance • clearance • creepage C250 250 V AC 2 500 V AC 1 500 V AC 2 500 V AC ³ 2,5 mm ³ 4 mm General data Operating time (typical value) Release time (typical value) Electrical life • resistive • cos j Mechanical life (cycles) Dimensions (L x W x H) Weight Ambient temperature • storing • operating Cover protection category Shock resistance Vibration resistance Solder bath temperature Soldering time Approvals 1 10 ms AC; 13 ms DC 8 ms AC; 3 ms DC at 12 A, 250 V AC ³ 10 5 see Fig. 2 ³ 2 x10 7 27,5 x 21,2 x 35,6 mm - plug-in standard version (WT) 27,5 x 21,2 x 33 mm - PCB version and version with threaded bolt 35 g -40...+85 °C AC: -40...+55 °C; DC: -40...+70 °C IP 40 10 g (NO); 5 g (NC) 5g for 10...150 Hz max. 270 °C max. 5 s B, cUL, UL, VDE, GOST 2 R2 Miniature plug-in power relays Coil data - DC version Coil code Table 1 Rated voltage V DC 1005 1006 1012 1024 1048 1060 1080 1110 1125 1220 5 6 12 24 48 60 80 110 125 220 Coil operating range V DC Coil resistance (±10%) at 20 °C W max. (at 55 °C) min. (at 20 °C) 4,0 4,8 9,6 19,2 38,4 48,0 64,0 88,0 100,0 176,0 28 40 160 640 2 600 4 000 7 100 13 600 16 000 54 000 5,5 6,6 13,2 26,4 52,8 66,0 88,0 121,0 137,5 242,0 Coil data - AC 50 Hz version Table 2 Coil operating range V AC min. (at 20 °C) 6 12 24 42 48 60 80 110 120 127 220 230/240 Electrical life at AC resistive load Fig. 1 6,6 13,2 26,4 46,2 52,8 66,0 88,0 121,0 132,0 139,0 242,0 253,0 4,8 9,6 19,2 33,6 38,4 48,0 64,0 88,0 96,0 101,6 176,0 184,0 12 50 190 565 785 1 240 2 190 3 880 4 150 4 940 16 300 17 400 Electrical life reduction factor at AC inductive load Fig. 2 F 1 0,8 0,6 Reduction factor 3006 3012 3024 3042 3048 3060 3080 3110 3120 3127 3220 3230 max. (at 55 °C) 0,4 1 0,8 3 0,6 0,4 cosj Power factor 0,2 R2 3 Miniature plug-in power relays Maximum DC resistive load breaking capacity Fig. 3 Connections diagram (pin side view) 50 12 10 12 (1) 42 (4) 14 (5) 44 (8) 11 (9) 41 (12) A1 (13) A2 (14) 5 2 1 0,5 Terminal (pin) 12(1); 42(4); 14(5); 44(8); 11(9); 41(12); A1(13); A2(14) mm 0,1 10 0,5 x 1,0 for relays f 1,3 mm ± 0,1 for sockets f 1,5 mm ± 0,1 Drilling hole 20 30 40 50 100 200 300 Dimensions - version with threaded bolt (without WT) Dimensions - plug-in version (WT), with manual testing/latching lever 21,1 21,2 33 6,6 6,6 21,2 6,5 6,3 6,5 6 35,6 6,2 6,3 6,3 4,1 27,5 27,4 27,5 M2,5 6,8 Dimensions - version with cover equipped with mounting flange (without WT) 43 8 3,5 38 28,4 6,5 33 2 22 Dimensions - PCB version (without WT) 4 R2 Miniature plug-in power relays Mounting Relays R2 are designed for: • screw terminals sockets GZT2 (modules and clips available) and GZR2 - for DIN rail mounting, • PCB terminals sockets SU4/2D - for PCB mounting,, • solder terminals sockets SU4/2L and G4/2, • direct PCB mounting. Ordering codes 10 - AgCdO 20 - AgNi 21 AgNi/Au 0,2 µm 23 - AgNi/Au 5 µm See Tables 1, 2, page 2 2C/O * - - -- LDLD WT WTL WTD WTLD - no additional features LED indicator arc suppressing diode LED indicator +arc suppressing diode indicating flag + manual testing/latching lever (standard) indicating flag + manual testing/latching lever + LED indicator indicating flag + manual testing/latching lever + arc suppressing diode indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode * D, LD, WTD, WTLD - only for DC coils WT - standard features plug-in power relays 2002-12-20