ZETTLER RY2101246WT

RY2
Plug-in power relays
• General purpose relays
• Plug-in version - rail mount TH35, EN 50022
Contacts
Contacts
Contact number & arrangement
Contact material
Voltage
Max. switching voltage AC/DC
Min. switching voltage AC/DC
Current
Rated load
AC1
DC1
Max. switching current
Min. inrush current
Rated current
Max. breaking capacity
AC1
Min. breaking capacity
Resistance
Max. operating frequency
• at rated load
• no load
2C/O
AgCdO
250 V / 250 V
10 V
12 A / 250 V AC
12 A / 30 V DC
20 A
10 mA
12 A
3 000 VA
0,5 W
£ 100 mW
at 100 mA, 24 V
1 200 cycles/hour
18 000 cycles/hour
Coil
Coil
Voltage
Rated voltage
on
5...220 V DC
6...230 V AC 50 Hz, 6...240 V AC 50/60 Hz
³ 0,1 Un DC; ³ 0,2 Un AC
see Tables 1, 2, 3
0,9 W DC
1,6 VA AC 50 Hz; 1,9 VA AC 50/60 Hz
Must release voltage
Operating range of supply voltage
Rated power consumption
Insulation
Insulation category
Voltage
Insulation rated voltage
Dielectric strength:
• coil-contact
• contact-contact
• pole-pole
Contact-coil distance
• clearance
• creepage
B250
250 V AC
2 500 V AC
1 000 V AC
2 500 V AC
³ 2,6 mm
³ 4 mm
General data
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive
• cos j
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storing
• operating
Cover protection category
Shock resistance
Vibration resistance
V
15 ms
10 ms
at 12 A 250 V AC
³ 105
see Fig. 2
³ 107
27,5 x 21,1 x 34,5 mm
35 g
-40...+70 °C
-40...+55 °C
IP 40
10 g
5g
for 15...150 Hz
1
2
RY2
Plug-in power relays
RY2
3
Plug-in power relays
Fig. 1
Electrical life reduction factor
at AC inductive load
Fig. 2
Reduction factor
Electrical life at AC resistive load
Power factor
Ncosj = N x F
Dimensions - cover with mounting flange
7,25
8
10
10
7,25
3,5
4 4,7 5,9
14,2
4 4,7 5,9
14,2
Dimensions - standard version
38
27,5
43
21,2
22
0,5
6,4
6,4
34,5
34,5
3
28,4
0,5
4,8
Connections diagram (pin side view)
12 (1)
42 (2)
14 (3)
44 (4)
11 (5)
41 (6)
A1 (7)
A2 (8)
4,8
Mounting
Relays RY2 are designed for:
• screw terminals sockets GZY2
(modules and clips available) - for DIN rail mounting,
• fast-on connector.
4
RY2
Plug-in power relays
Ordering codes
10
See Tables 1, 2, 3, page 2
6 - connectors / plug-in
*
- - -- LDLD WT WTL WTD WTLD -
no additional features
LED indicator
arc suppressing diode
LED indicator +arc suppressing diode
indicating flag + manual testing/latching lever (standard)
indicating flag + manual testing/latching lever + LED indicator
indicating flag + manual testing/latching lever + arc suppressing diode
indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode
* D, LD, WTD, WTLD - only for DC coils
2002-12-20