ZETTLER R3211443

R4
Miniature plug-in power relays
6 A/250 V AC
Contacts
Contact number & arrangement
Contact material
Voltage
Max. switching voltage AC/DC
Min. switching voltage
Current
Rated load
• WT - standard plug-in version with indicating flag and manual testing/latching lever
• Miniature size
• Cadmium - free contacts
• Coil AC and DC
• Plug-in version - rail mount TH35, EN 50022
• Plug-in, solder, PCB versions available
• General purpose relays
4C/O
AgNi; AgNi/Au 0,2 µm; AgNi/Au 5 µm
250 V / 250 V
5V
AC1
DC1
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Resistance
Max. operating frequency
• at rated load
• no load
AC1
AC1
6 A / 250 V AC - plug-in version
5 A / 250 V AC - PCB version
6 A / 24 V DC - plug-in version
5 A / 24 V DC - PCB version
5 mA (AgNi, AgNi/Au 0,2 µm)
1 mA (AgNi/Au 5 µm)
12 A
6 A - plug-in version
5 A - PCB version
1 500 VA - plug-in version
1 250 VA - PCB version
0,1 W (AgNi/Au 5 µm); 0,3 W (AgNi, AgNi/Au 0,2 µm)
£ 100 mW
at 100 mA, 24 V
1 200 cycles/hour
18 000 cycles/hour
Coil
Voltage
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
5...220V DC
6...240 V AC 50 Hz
³ 0,1 Un DC; ³ 0,2 Un AC
see Tables 1, 2
0,9 W DC; 1,6 VA AC
Insulation
Insulation category
Voltage
Insulation rated voltage
Dielectric strength
• coil-contact
• contact-contact
• pole-pole
Contact-coil distance
• clearance
• creepage
B250
250 V AC
2 500 V AC
1 500 V AC
2 000 V AC
³ 1,6 mm
³ 3,2 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive
• cos j
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storing
• operating
Cover protection category
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
Approvals
1
10 ms AC; 13 ms DC
8 ms AC; 3 ms DC
³ 10
5
at 6 A, 250 V AC
see Fig. 2
³ 2 x 10 7
27,5 x 21,2 x 35,6 mm - plug-in standard version (WT)
27,5 x 21,2 x 33 mm - PCB version
and version with threaded bolt
35 g
-40...+85 °C
AC: -40...+55 °C; DC: -40...+70 °C
IP 40
10 g (NO); 5 g (NC)
5g
for 10...150 Hz
max. 270 °C
max. 5 s
B, cUL, UL, VDE, GOST
2
R4
Miniature plug-in power relays
Coil data - DC version
Coil code
Table 1
Rated voltage
V DC
1005
1006
1012
1024
1048
1060
1080
1110
1125
1220
5
6
12
24
48
60
80
110
125
220
Coil operating range
V DC
Coil resistance
(±10%) at 20 °C
W
max. (at 55 °C)
min. (at 20 °C)
4,0
4,8
9,6
19,2
38,4
48,0
64,0
88,0
100,0
176,0
28
40
160
640
2 600
4 000
7 100
13 600
16 000
54 000
5,5
6,6
13,2
26,4
52,8
66,0
88,0
121,0
137,5
242,0
Coil data - AC 50 Hz version
Table 2
Coil operating range
V AC
min. (at 20 °C)
6
12
24
42
48
60
80
110
120
127
220
230/240
Electrical life at AC resistive load
Fig. 1
6,6
13,2
26,4
46,2
52,8
66,0
88,0
121,0
132,0
139,0
242,0
253,0
4,8
9,6
19,2
33,6
38,4
48,0
64,0
88,0
96,0
101,6
176,0
184,0
12
50
190
565
785
1 240
2 190
3 880
4 150
4 940
16 300
17 400
Electrical life reduction factor
at AC inductive load
Fig. 2
F
1
0,8
Reduction factor
3006
3012
3024
3042
3048
3060
3080
3110
3120
3127
3220
3230
max. (at 55 °C)
0,6
0,4
1 0,8
0,6
0,4
cosj
Power factor
0,2
R4
Miniature plug-in power relays
3
4
R4
Miniature plug-in power relays
Mounting
Relays R4 are designed for:
• screw terminals sockets GZT4 (modules and clips available) and GZ4 - for DIN rail mounting,
• PCB terminals sockets SU4D - for PCB mounting,,
• solder terminals sockets SU4L and G4,
• direct PCB mounting.
Ordering codes
20 - AgNi
21 AgNi/Au 0,2 µm
23 - AgNi/Au 5 µm
See Tables 1, 2, page 2
14 - 4C/O
*
- -- - LDLD WT WTL WTD WTLD -
no additional features
LED indicator
arc suppressing diode
LED indicator +arc suppressing diode
indicating flag + manual testing/latching lever (standard)
indicating flag + manual testing/latching lever + LED indicator
indicating flag + manual testing/latching lever + arc suppressing diode
indicating flag + manual testing/latching lever + LED indicator + arc suppressing diode
* D, LD, WTD, WTLD - only for DC coils
WT - standard features plug-in power relays
2002-12-20