ACT ACTF480-2

Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
The ACTF480-2/479.5/TO39 is a two channel IF filter for DSB receivers with
constant group delay.
1.Package Dimension (TO-39)
2.
Pin
Configuration
1
Input / Output
2
Output 2 / Input2
3
Output 1 / Input1
4
Ground
Dimensions
Data (Unit: mm)
A
9.35±0.10
B
5.08±0.10
C
3.40±0.10
D
3.00±0.20
E
4-Φ0.45±0.20
3.Equivalent LC Model
4.Performance
4-1.Maximum Ratings
Rating
Value
Units
AC Voltage Between Any Two Pins
V PP
5
V
DC Voltage Between Any Two Pins
Storage temperature range
V DC
T stg
0
V
-40 to +85
°C
Operable temperature range
TA
-25 to +85
°C
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
4-2.Electronic Characteristics
TA = 25 °C
Reference temperature:
Terminating source impedance:
ZS = 50 Ω
Terminating load impedance:
ZL = 50 Ω
0.25MHz
Group delay aperture:
Characteristics of Channel1
Characteristic
Center Frequency
fc
Insertion attenuation
479.50 MHz
(Reference level for the following data)
α
αrel≤3dB
B3dB
Pass bandwidth
Typ.
Max.
Units
478.50
479.50
480.50
MHz
--
21.0
22.5
dB
--
27.0
--
MHz
--32.0
30.0
3.3
2.5
38.0
36.0
4.5
4.5
---
dB
dB
dB
dB
40.0
49.0
--
dB
αrel
Relative attenuation
Lower sidelobe
Upper sidelobe
Min.
466.00 MHz
493.00 MHz
430.00 ….452.00 MHz
507.00 … 530.00 MHz
Reflected wave signal suppression
0.13μs … 2.0μs after main pulse
Amplitude ripple (p-p)
471.00 … 488.00 MHz
Δα
--
0.6
1.2
dB
Group delay ripple (p-p)
466.00 … 493.00 MHz
Δτ
--
11
18
ns
--
-86
--
ppm/K
Temperature coefficient of frequency
TCf
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
Characteristics of Channel2
Characteristic
Center Frequency
fc
Insertion attenuation
479.50 MHz
(Reference level for the following data)
α
αrel≤3dB
B3dB
Pass bandwidth
Typ.
Max.
Units
478.50
479.50
480.50
MHz
--
21.0
22.5
dB
--
18.0
--
MHz
--32.0
30.0
3.5
2.3
38.0
36.0
4.5
4.5
---
dB
dB
dB
dB
40.0
44.0
--
dB
αrel
Relative attenuation
Lower sidelobe
Upper sidelobe
Min.
470.50 MHz
488.50 MHz
430.00 ….457.50 MHz
500.50 … 530.00 MHz
Reflected wave signal suppression
0.13μs … 3.0μs after main pulse
Amplitude ripple (p-p)
476.00 … 483.00 MHz
Δα
--
0.6
1.2
dB
Group delay ripple (p-p)
470.50 … 488.50 MHz
Δτ
--
11
18
ns
--
-86
--
ppm/K
Temperature coefficient of frequency
TCf
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
5.Typical Frequency Response
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
2.
3.
4.
5.
6.
The frequency f C is defined as the midpoint between the 3dB frequencies.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50Ω test system with VSWR≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
Issue : 1 C1
Date : SEPT 04