ACT ACTF9006

Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
This following specification covers the characteristics of SAW Filter
ACTF9006/915.0/DCC6C for ISM900 applications.
1.Package Dimensions (DCC6C)
2.
Pin
Configuration
2
Input / Output
5
Output / Input
others
Case Ground
Sign
Data (unit: mm)
Sign
Data (unit: mm)
A
0.6
E
1.1
B
1.5
F
3.0
C
1.5
G
3.0
D
1.8
3.Test Circuit
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
1 OF 3
Issue : 1 C1
Date : SEPT 04
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
4. Frequency Characteristics
5.Performance
5-1.Maximum Ratings
Value
Units
Input Power Level
+15
dBm
DC Voltage
12V
VDC
-40 to +85
°C
+235
°C
Rating
Storage Temperature
Soldering Temperature
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
Issue : 1 C1
For quotations or further information please contact us at:
Date : SEPT 04
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
2 OF 3
Tel : +44 118 979 1238
Fax : +44 118 979 1283
Email: [email protected]
5-2.Electronic Characteristics
Characteristic
Min.
Centre Frequency
(Centre frequency between 3dB points)
fC
Insertion Loss (f C±5MHz)
IL
Ripple (fC±5MHz)
3dB Passband
BW 3
Typ.
Max.
915.000
Units
MHz
--
3.5
5.5
dB
--
±0.5
±1.0
dB
--
36
--
MHz
42
36
23
38
50
45
27
48
-----
dB
α
Absolute Attenuation
D.C. ~ fC -120MHz
fC - 120MHz ~ fC - 50MHz
fC +35MHz ~ fC +100MHz
fC +100MHz ~ fC +200MHz
Input/Output Impedance
50
Ω
iCAUTION: Electrostatic Sensitive Device. Observe precautions for handling!
1.
2.
3.
4.
5.
6.
The frequency f C is defined as the midpoint between the 3dB frequencies.
Unless noted otherwise, all measurements are made with the filter installed in the specified test fixture that is
connected to a 50 Ω test system with VSWR ≤1.2:1. The test fixture L and C are adjusted for minimum insertion
loss at the filter centre frequency, f C. Note that insertion loss, bandwidth, and passband shape are dependent on
the impedance matching component values and quality.
Unless noted otherwise, specifications apply over the entire specified operating temperature range.
The specifications of this device are based on the test circuit shown above and subject to change or
obsolescence without notice.
All equipment designs utilizing this product must be approved by the appropriate government agency prior to
manufacture or sale.
Our liability is only assumed for the Surface Acoustic Wave (SAW) component(s) per se, not for applications,
processes and circuits implemented within components or assemblies.
In keeping with our ongoing policy of product evolvement and improvement, the above specification is subject to change without notice.
ISO9001: 2000 Registered - Registration number 6830/2
For quotations or further information please contact us at:
3 The Business Centre, Molly Millars Lane, Wokingham, Berks, RG41 2EY, UK
http://www.actcrystals.com
3 OF 3
Issue : 1 C1
Date : SEPT 04