ETC BXA30-48D15-F

BXA30 Series
Single and dual output
DC/DC CONVERTERS
30W Wide Input DC/DC Converters
1
• Designed to meet telecom power supply interface
standard ETS300-132-2
• UL, VDE and CSA safety approvals
• VDE0878 and EN55022 conducted emissions level A
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• Fixed frequency operation at 350kHz
• MTBF in excess of 7,005,000 hours (demonstrated)
• Basic insulation system
The BXA30 series, comprising 9 different models, has been conceived as an
applications-specific range of DC/DC converters, specifically addressing
telecommunications, industrial electronics, test equipment, mobile telecommunications
and distributed power applications. The series offers three wide input voltage ranges, 918VDC and 36-75VDC, and is available in single and dual output versions. Designed to
meet ETSI telecoms interface standards ETS300-132-2 and BTR2511, together with
internal filtering to EN55022 level A, safety approval to EN60950 and UL1950, and
isolation of 1500VDC, the 48VDC models are ideal for telecommunications applications.
The 12V models are particularly suited to industrial, mobile telecom and test equipment
applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliant. Other
features include low output ripple, overvoltage protection, continuous short circuit
protection, remote enable and remote sense.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
Singles
Line regulation
LL to HL (single/dual)
±0.2%/±0.4%
Load regulation
FL to NL (single/dual)
±0.2%/±0.4%
Ripple and noise
(20MHz bandwidth)
3.3V
5.0V
All others
All models
60mV pk-pk
50mV pk-pk
100mV pk-pk
20mV rms
Temperature coefficient
±0.02%/°C
Overvoltage protection
Transient
Short circuit protection
Singles
Duals (single short)
Duals (dual short)
Transient response
±10%
135% Vout
Continuous
(See BXA15/30
Design Note 100)
Continuous
25% to 100% load
4.0%
Voltage accuracy
Load cross regulation
±1.5%
Dual output
30% to 100% output variation
3.0%
INPUT SPECIFICATIONS
Input voltage range
Remote ON/OFF
Logic compatibility
ON
OFF
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
EN55022, FCC part 15 (Note 4) Level A
EN55022, FCC part 15 (Note 5) Level B
VDE0878 (Note 4) (48V)
Level A
EN55022, FCC part 15
Level A
EN61000-4-2, level 3
Perf. criteria 2
EN61000-4-2, level 4
Perf. criteria 2
EN61000-4-5, level 3
Perf. criteria 2
EN61000-4-4, level 3
Perf. criteria 2
EN61000-4-3, level 3
Perf. criteria 2
EN61000-4-6, level 3
Perf. criteria 2
GENERAL SPECIFICATIONS
Efficiency
See table
Isolation voltage
Basic insulation
Input/output
input/case, 48V models
Switching frequency
Fixed
1500VDC
1500VDC
350kHz
Approvals and
standards
(See Note 12)
VDE0805, EN60950
IEC950, UL1950
CSA C22.2 No. 950
Case material
Aluminum substrate
with plastic case
Material flammability
12Vin nominal
48Vin nominal
Reverse voltage
protection (See Note 7)
Max. input rise and
fall time
Conducted emissions
9 to 18VDC
36 to 75VDC
Yes
UL94V-0
Weight
MTBF (See Note 9)
120g (4.24oz)
Demonstrated @ 25°C
7,005,000 hours
ENVIRONMENTAL SPECIFICATIONS
48V
5V/ms
ETS300-132
CMOS/TTL
Open circuit
<1VDC
Thermal performance
Thermal impedance
Baseplate operating
temperature,
(See Notes 6, 8)
Non-operating
-25°C to +100°C
-55°C to +100°C
Free air convection,
baseplate to air
With heatsink (See Note 8)
6.5°C/W
5.2°C/W
File Name: BXA30.PDF Rev: 02 Oct 2002
BXA30 Series
Single and dual output
DC/DC CONVERTERS
30W Wide Input DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT (MAX.)
INPUT
CURRENT
9-18VDC
5.0V
5.0A
100mA
80%
±0.2%
±0.2%
BXA30-12S05
36-75VDC
3.3V
6.0A
30mA
75%
±0.2%
±0.2%
BXA30-48S3V3
36-75VDC
3.3V
8.0A
30mA
81%
±0.2%
±0.2%
BXA30-48S3V3/8
36-75VDC
5.0V
5.0A
30mA
80%
±0.4%
±1.0%
BXA30-48S05
36-75VDC
12.0V
2.5A
30mA
85%
±0.2%
±0.2%
BXA30-48S12
36-75VDC
15.0V
2.0A
30mA
87%
±0.2%
±0.2%
BXA30-48S15
(1)
TYPICAL
EFFICIENCY
REGULATION
LINE (2)
LOAD
(3)
MODEL
NUMBER (4,6)
36-75VDC
±5.0V
±2.5A
30mA
80%
±0.4%
±0.4%
BXA30-48D05
36-75VDC
±12.0V
±1.25A
30mA
84%
±0.4%
±0.4%
BXA30-48D12
36-75VDC
±15.0V
±1.0A
30mA
86%
±0.4%
±0.4%
BXA30-48D15
(11)
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
Nominal, at no load.
Low line to high line.
Full load to no-load. For duals, the value stated is for balanced loads.
An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model
number, e.g. BXA30-48S12-F. See BXA15 and BXA30 Design Note 100.
For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
For extended operating temperature, include the heatsink option, ‘-1’ in the
model number. Max. heatsink height is 12.5mm, e.g. BXA30-48S15-1
Reverse voltage protection can be implemented by putting a slow blow
fuse on the negative input rail. Rate the fuse for 48VDC at 1.5A and 12VDC
at 6A.
The maximum operating ambient temperature, without derating depends
on internal power dissipation and hence efficiency and cooling method.
BXA15 and BXA30 Design Note 100 provides detailed thermal calculations
and design-in details.
Test results to-date are 1,590,000 hours @ 46˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation
energy of -0.55 eV.
Visit the Artesyn website to download a copy of Design Note 100.
This model has the same electrical pin-out and pin pitch spacings as the
drawing on the following page. Dimensions are 76.2 x 76.2 x 14.2mm,
±0.3mm.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
If remote sense is not used, connect +sense to +vout and -sense to -vout.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 14501-3336-7006
Licence No. 6231
UL1950 File No. E174104
CSA C22.2 No. 950 File No. LR41062C
Please consult our website for the following items: ✔ Design Note
www.artesyn.com
File Name: BXA30.PDF Rev: 02 Oct 2002
BXA30 Series
Single and dual output
DC/DC CONVERTERS
30W Wide Input DC/DC Converters
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
PIN CONNECTIONS
EXTERNAL OUTPUT TRIMMING
PIN NUMBER
SINGLE OUTPUT
DUAL OUTPUT
1
+ Vin
+ Vin
2
– Vin
– Vin
(13)
3
+ Sense
4
Trim
Common
5
– Sense
– Vout
6
+ Vout
No Pin
Single output models can be
externally trimmed by ±10%
using either method shown.
5
5
TRIM
UP
4
4
+ Vout
TRIM
DOWN
3
3
7
– Vout
No Pin
8
Remote ON/OFF
Remote ON/OFF
2.50
(63.5)
0.20 (5.08)
0.80 (20.32)
0.50 (12.70)
10KΩ
TRIMPOT
0.76
(19.20±0.30)
3.02
(76.30 ± 0.30)
0.302
(7.67±0.30)
0.20
(5.08)
3
8
4
5
0.6 (15.24)
0.95
(24.13)
1
0.70 (17.78)
0.30 (7.62)
6
BOTTOM
VIEW
7
2.41
(61.10±0.30)
0.4 (10.16)
2
1.30
(33.02)
1.15
(29.21)
Ø 1.000
8 Places
Case/Metal Inserts M3.0
(Typ. 4 Places)
2.00
(50.80)
ALL DIMENSIONS IN INCHES (mm)
0.52
(13.30±0.30)
SIDE VIEW
Tolerance .XX ±0.02
.XXX ±0.005
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Design Note
www.artesyn.com
File Name: BXA30.PDF Rev: 02 Oct 2002