ARTESYN SXA10

SXA10 Series
Single output
DC/DC CONVERTERS
•
•
•
•
•
•
•
•
•
10W Surface Mount DC/DC Converters
1
Surface mount isolated DC/DC converter
High reliability, rugged design
Low weight, open frame package
Wide operating temperature range of -40°C to +85°C
with natural convection
Capable of delivering 10% extra power from -10°C to 70°C
Compliant with industry standard reflow profiles
Excellent output voltage accuracy, 0.1% typical regulation
Complies with ETS 300 132-2, ETS 300 386-1
MTBF of 2,000,000 hours demonstrated @ 25˚C
The SXA10 series is targeted specifically at telecommunications, data networking, mobile
infrastructure, industrial and computer distributed power applications. An open frame
topology combining a custom IC, conservative component deratings and extensive
qualification ensures enhanced performance and reliability. All models have remote enable,
output voltage trim and adjustable undervoltage lockout setting. The products are
manufactured in a fully automated process utilising established and proven mechanical
construction technologies. Supplied in JEDEC standard trays, these products are optimized
for automated assembly using standard pick and place equipment and using industry
standard reflow profiles.
TÜV
5 YEAR WARRANTY
All specifications are valid over 27-75V input, no load to rated load and -40°C to 110°C hot spot
(output diode tab temperature), unless otherwise stated.
OUTPUT SPECIFICATIONS
TYPICAL EMC CHARACTERISTICS
Voltage setpoint accuracy (See Note 1)
±1.0% max.
Voltage adjustability
±10%
Line regulation
27 to 75V
Load regulation
Full load to no load
15mV max.
See model table
Minimum load
Ripple and noise (max.)
20MHz bandwidth
0A
S2V5
S3V3
S05
S12
4.0%
3.0%
2.0%
1.0%
pk-pk,
pk-pk,
pk-pk,
pk-pk,
35mV
35mV
30mV
30mV
rms
rms
rms
rms
Conducted emissions
Radiated emissions
Electrostatic discharge
Radiated immunity
Input transients bursts
Surge (signal only)
Conducted immunity
Input transients
Public telecom,
network equip. EMC
Digital cellular telecom
EMC
EN55022, FCC P.15
EN55022, FCC P.15,
EN61000-4-2 (4kV)
EN61000-4-3 (10V/m)
EN61000-4-4 (4kV)
EN61000-4-5 (500V)
EN61000-4-6
ETS 300 132, ETR283
ETS 300 386-1,
April 1997
ETS 300 342-2,
November 1994
Temperature coefficient
±0.01%/°C
GENERAL SPECIFICATIONS
Short circuit and
overload protection
Continuous
Efficiency
(For other operating conditions,
refer to Application Note 102)
Load transient response
Peak deviation for 50%
to 100% step load
Settling time to within 1.0%
1.4% typ.
200µs typ.
INPUT SPECIFICATIONS
Input voltage range
Adjustable input
voltage range
Recommended
input fuse
UVLO turn ON voltage
UVLO turn OFF voltage
Remote ON/OFF
Logic compatibility
ON
OFF
Default
SPECIFICATIONS
36 to 75VDC
27 to 75VDC
Input/output, 1second test
Insulation class
Operational
Switching frequency
Fixed
Approvals and
standards
(See Application Note 102)
(See Application Note 102)
Internally pulled high
Open Collector
Open circuit or >2.25V
<1.47V
NOTE: The component top surface contains both input and output
voltage potentials. The component may also be at high temperature.
Ensure that the unit is accessible only to trained personnel.
2,
3,
4,
1,
3,
See model table
Isolation voltage
Weight
850mA HRC, anti-surge
rated for 200VDC
Level
Level
Level
Level
Level
Level A
Level A
criterion 2
criterion 1
criterion 2
criterion 1
criterion 1
1500VDC
IEC60950, UL1950
400kHz, ±10%
EN60950, UL1950
14g (0.5oz) typ.
Material flammability
UL94V-0
Nominal dimensions
(See drawings)
2.0 x 1.12 x 0.41 inches
50.8 x 28.5 x 10.4 mm
MTBF (parts count)
MTBF (demonstrated)
MIL-HDBK-217F
1,000,000 hours
Ground benign @ 30°C
25˚C (See Note 3)
2,900,000 hours
Max. lead coplanarity
±0.002 inches (±50µm)
Leadout
Solder paste height
SMT Gullwing
0.15mm (6 thou) min.
File Name: SXA10.PDF Rev: 08 Mar 2002
SXA10 Series
Single output
DC/DC CONVERTERS
10W Surface Mount DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT
VOLTAGE RANGE
NOMINAL
OUTPUT VOLTAGE
NOMINAL OUTPUT
CURRENT
MINIMUM
EFFICIENCY (1)
MAXIMUM
LOAD REG.(1)
MODEL
NUMBER (4)
27-75VDC
2.25 to 2.75V
2.5V
2.75A
76%
20mV
SXA10-48S2V5
27-75VDC
2.97 to 3.63V
3.3V
2.75A
79%
20mV
SXA10-48S3V3
27-75VDC
4.5 to 5.5V
5.0V
2.0A
82%
20mV
SXA10-48S05
27-75VDC
10.8 to 13.2V
12V
0.833A
84%
30mV
SXA10-48S12
GENERAL SPECIFICATIONS (Cont.)
Recommended reflow
profile
0.008
(0.20)
Min.
Convection reflow is recommended
CECC 00 802 Issue 2 and peak <245˚C
See Application Note 102
Clean
Ambient (still air)
3.5° ±1.5°
(3)
Unit mounted
-40˚C to +85˚C
vertically, with >3cm2
copper trace
heat-sinking at each
output pin on mounting board
Storage temperature
Seating
Plane
1.120 ±0.012
(28.50 ±0.30)
Recommended process
is no clean. If aqueous,
ensure unit is thoroughly dried
before applying power
ENVIRONMENTAL SPECIFICATIONS
0.42
(10.60)
Max.
0.057 ±0.004
(1.45 ±0.1)
-40˚C to +125˚C
Detailed environmental specifications are given on the
long form data sheet available on the website
+0.008
2.000 -0.004
)
(50.80 +0.20
-0.10
Notes
1
2
3
4
Valid for 48V input, nominal load and 25˚C operation.
For applications with input voltages between 36 and 75V, and operating
ambient temperatures of -10˚C to +70˚C the device will deliver an extra
10% output power. The device will continue to meet all specifications
listed in this data sheet. See output characteristic diagram below.
Demonstrated life test to-date is 1,300,000 hours at 36˚C. This figure
includes a calculated acceleration factor of 2.14, based on an activation
energy of 0.55eV.
To order an Evaluation Kit which contains a SXA10 model pre-mounted
on a circuit card with test points for easy testing in the laboratory, please
add the suffix ‘-EVAL’ to the model number, e.g. SXA10-48S05-EVAL.
Please see the SXA10 Evaluation Board User Guide for further details.
VO+
1
20
NC
VO-
2
19
NC
VO+
3
18
NC
VO-
4
17
TRIM
VO-
5
16
NC
NC
6
15
NC
NC
7
14
NC
NC
8
13
NC
NC
9
12
UV/REM
Vin+
10
11
Vin-
0.004
(0.10)
0.200 ±0.001
(5.08 ±0.03)
Seating
Plane
Typ.
(Non. Accum.)
0.010 ±0.002
(0.25 ±0.05)
0.098 ±0.004
(2.50 ±0.10)
DIMENSIONS IN INCHES (MM)
Output
Power
Input Voltage
Range
Made in Ireland
Nom. (+10%)
Nom.
36 to 75VDC
25 to 75VDC
Still Air
-40°C
>0.3msec-1
Forced Air
(60lfm)
70°C
-10°C
85°C
100°C
Ambient Temperature
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note ✔ Longform Data Sheet ✔ Evaluation Kit
www.artesyn.com
File Name: SXA10.PDF Rev: 08 Mar 2002