ASTEC ADN40-24-3PM

120-960 Watts
ADN Series
Total Power: 120 - 960 Watts
Input Voltage: 1Ø or 3Ø 380-480 VAC
# of Outputs: One
3-Phase
Electrical Specs
Input
Nominal voltage
Power factor (PFC)
AC Input range
DC Input range
Frequency
Phase
380-480 VAC
EN61000-3-2
340-576 VAC
450-820 VDC
47 - 63 Hz, 500 Hz
1Ø or 3Ø on 5, 10 & 20A* models.
30A & 40A models are 3Ø only.
Output
Nominal voltage
Holdup time
Tolerance
Special Features
•Complies with EN61000-3-2
•DC OK Signal (indicator)
•Adjustable Voltage
•Industrial grade design
(no derating to 60°C)
•User-friendly front panel
•Single phase input available
•Highly efficient >90% switching technology
•High MTBF and reliability
•Peak current capability 2x rated
current for 2 seconds
•Three year warranty
24V (22.5 - 28.5 VDC Adj.)
>20ms at full load (25°C)
<±2% overall
(combination line/load/time/temp)
Line regulation
<0.5%
Load regulation
<0.5%
Time & temp. drift
<1%
Initial voltage setting
24.5V ±1%
Ripple
<50mVpp
Parallel Operation
Current limit (fold forward)
constant power
10A, 20A, 30A
User selectable
40A
Active single wire parallel
Over voltage protection >30.5 <33 VDC
*On 20A unit, derate to 75% when operating 1Ø.
Safety
EMC
Emissions
Environmental
Storage/shipment
Operating
(convection)
Humidity
-25°C to +85°C
-10°C to 60°C
(derate to 50% at +70°C)
<90% RH noncondensing
per IEC 68-2-2, 68-2-3
IP20 (EN60529), protection
from moisture & condensation
Note: Derate output to 50% when unit is
mounted sideways or front side up.
190
Immunity
Approvals
Protection
EN500081-1, -2 Class B EN55011, EN55022
Radiated and Conducted including Annex A.
EN50082-1, -2; EN61000-4-2, Level 4,
EN61000-4-3 Level 3, EN61000-4-6 Level 3;
EN61000-4-4 Level 4 input and Level 3 output;
EN61000-4-5 Isolation Class 4, EN61000-4-11;
Transient resistance according to VDE
0160/W2 over entire load range.
CB Scheme, EN60950; EN50178; EN60204;
UL508 Listed, cULus; UL60950, cRUus, CE (LVD
73/23 & 93/68/EEC) EN61000-3-2, IEC 6007915 Class 1, Zone 2 hazardous location, Groups
IIA, IIB, IIC w/T3 temp class up to 60°C
Ambient.
Class 1 (IEC536), degree of protection
SELV rated per EN60950
Technical Support: (888) 41ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 03.25.05
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
ADN Series
Ordering Information
Model
Weight
Power
Input Voltage
Current
ADN5-24-3PM
ADN10-24-3PM
ADN20-24-3PM
ADN30-24-3PM
ADN40-24-3PM
1.7lbs (730g)
2.16lbs (980g)
3.97lbs. (1800g)
4.0lbs (2000g)
6.6lbs (3300g)
120W
240W
480W
720W
960W
380-480VAC
380-480VAC
380-480VAC
380-480VAC
380-480VAC
5A
10A
20A
30A
40A
Catalog Number
ADN5-24-3PM
Catalog Number
ADN10-24-3PM
ADN20-24-3PM
ADN30-24-3PM
ADN40-24-3PM
Dimensions - inches (mm)
H
4.88 (124)
W
2.91 (73)
D
4.55 (116)
Dimensions - inches (mm)
H
4.88 (124)
4.88 (124)
4.88 (124)
4.88 (124)
W
3.50 (89)
5.90 (150)
9.72 (247)
11.10 (282)
D
4.55 (116)
4.55 (116)
4.55 (116)
4.55 (116)
Installation
Fusing
-Input
-Output
Mounting
Connections
Internally fused.
Outputs are capable of providing high currents for short periods of time for inductive load startup or switching.
Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current
overload allows for reliable fuse tripping.
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDNPMBRK2 required).
Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12
AWG (0.5-4 mm2) for standard conductors. Output: Two connectors per output, connector size range:
16-10 AWG (1.5 - 6mm2) for solid conductors.
Case
-Free Space
www.astecpower.com
Fully enclosed metal housing with fine ventilation grid to keep out small parts.
25mm above and below
25 mm left and right
15 mm in front
70 mm above and below
25 mm left and right
15 mm in front
191