ASTEC DA16

16 Watts
DA16 Series
Total Power:
Input Voltage:
# of Outputs:
16 Watts
90-264 VAC
Single
Electrical Specs
Input
DA16-UK
DA16-EU
DA16-US
Input range
Frequency
Inrush current
Input current
Efficiency
EMI/RFI
90 - 264 VAC (wide range)
47 - 63 Hz
40A @ 230 VAC, cold start @ 25C
0.18A rms @ 120 VAC; 0.36A @ 240VAC
75% @ full load typical, @120VAC
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B, EN55013 and EN50083-2
Safety Ground
leakage current
300µA max. @ 50/60 Hz, 230 VAC input
Output
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Switching wallmount power supply
Available in multiple AC plug configurations
CE Mark EMC & LVD
Universal AC input
Fully regulated output
Overload and short circuit protection
Thermal protection
Designed to meet Blue Angel standard
European Code of Conduct compliance
Constant voltage
High efficiency
High MTBF
Built in EMI filter (CISPR 22 Class B)
LED power good indicator
Voltage (Vo)
Voltage regulation
Maximum Power (Po)
Hold-up time
Overvoltage protection
Overload protection
Overtemperature
protection
Output cable/connector
barrel polarity
12.2V
± 3.5% @ constant voltage mode
16W
20 ms. typical at full load @ 115VAC
Non-latching type
Output short circuit protection auto recover.
Overload protected @ 150% above maximum
rating.
Auto recovery
DC cable with 2.5 mm x5.5mm barrel plug
DC plug center +v
DC plug outer -v
AC Plug Configuration
U.S. 2-prong
Europe 2-prong
United Kingdom 3-prong
US
EU
UK
Environmental
Operating temperature: 0°C to +40°C ambient
Storage temperature: -40°C to +85°C
Electromagnetic susceptability; design to meet
EN55024
Humidity: Operating; non-condensing; 5% to
95% RH
Vibration: Three orthogonal axes, sweep at 1
oct/min. 5 min. dwell at four major resonances 2G
peak 8 Hz to 500 Hz, operational
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
190
Safety
UL
CUL
NEMKO
TUV
CB
CE
60950 / 6500
60950
60950 / 60065
60950
Certificate and report
EMC & LVD
Technical Support: (888) 41ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 02.10.05
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
DA16
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
DA16-120US
DA16-120EU
DA16-120UK
16W
16W
16W
12.2V
12.2V
12.2V
Minimum
Load
Maximum
Load
0.2A
0.2A
0.2A
1.33A
1.33A
1.33A
Peak
Load1
1.5A
1.5A
1.5A
Regulation2
Ripple
P/P (PARD)3
± 2%
± 2%
± 2%
120mV
120mV
120mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum loads are required.
DA16-XXX-EU
DA16-XXX-US
(2,000) 78.7
(2,000) 78.7
(60) 2.36
(10.5) 0.41
(53.0) 2.08
(53.0) 2.08
(10.5)) 0.41
(60) 2.36
(77.0) 3.03
(77.0) 3.03
DA16-XXX-UK
(18.0) 0.71
( 29.8 ) 1.17
(1.50) 0.06
(12.7) 0.50
(3.9) 0.13
(10.5) 0.41"
(19.5) 0.76
(16.0) 0.63
(13.8) 0.54
( 29.8 ) 1.17
(7.0) 0.27
(12.7) 0.50
(0.25) 0.01
(75.0) 2.95
(75.0) 2.95
(18.7) 0.74
(17.4) 0.68
(2,000) 78.7
(53.0) 2.08
(10.5) 0.41
(60) 2.36
(77.0) 3.03
(75.0) 2.95
(8.02) 0.32
(7.91) 0.31
(29.8) 1.17
(7.0) 0.27
(22.73) 0.89
(3.95) 0.15
NOTES:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± .02”
3. Warranty: 1 year
4. Weight: 0.325 lb. / 0.148 kg.
17.7 0.70
(4.03) 0.15"
(6.25) 0.25
(3.96) 0.15
www.astecpower.com
191