INSTALLATION INSTRUCTIONS TPC Series Industrial and Residential Power Supply Table of Models and Rated Values Order Code Rated AC-Input Voltage Range Operational Input Rated Output Voltage Range Power max. Rated Output * Output Voltage Adjustment Range TPC 030-105 TPC 030-112 20 Watt 26,4 Watt 5.0Vdc / 4.0A 12.0Vdc / 2.2A 5.0 – 6.0Vdc 12.0 – 15.0Vdc TPC 030-124 TPC 030-148 TPC 055-112 TPC 055-124 TPC 055-148 TPC 080-112 TPC 080-124 30 Watt 30 Watt 42 Watt 55 Watt 55 Watt 72 Watt 80 Watt 24.0Vdc / 1.25A 48.0Vdc / 0.6A 12.0Vdc / 3.5A 24.0Vdc / 2.3A 48.0Vdc / 1.15A 12.0Vdc / 6.0A 24.0Vdc / 3.3A 24.0 – 28.8Vdc 48.0 – 56.0Vdc 12.0 – 15.0Vdc 24.0 – 28.8Vdc 48.0 – 56.0Vdc 12.0 – 15.0Vdc 24.0 – 28.8Vdc TPC 080-148 80 Watt 48.0Vdc / 1.7A 48.0 – 56.0Vdc TPC 120-112 96 Watt 12.0Vdc / 8.0A 12.0 – 15.0Vdc TPC 120-124 120 Watt 24.0Vdc / 5.0A 24.0 – 28.8Vdc TPC 120-148 120 Watt 48.0Vdc / 2.5A 48.0 – 56.0Vdc Nominal 85Vac – 264Vac 110Vac – 240Vac 47 – 63Hz 50 – 60Hz 130Vdc - 300Vdc 90Vdc - 375Vdc recommended Circuit breaker (Characteristic C) 6A * Adjustable by potentiometer with a screwdriver. Connection and Ambient Conditions Operating temperature range: Natural Air Convection Cooling Output Power Derating: -25°C – +70°C max, above +50°C see derating below -13°F – +158°F max at nominal load, above +122°F see derating below above +50°C 2.5%/°C up to +70°C % above 122°F 1.4 /°F up to +158°F <100Vac input voltage output power has to be derated by 2.5%/V for continuous operation % <130Vdc input voltage output power has to be derated by 1 /V for continuous operation Storage temperature range: -25°C – +85°C max -13°F – +185°F max Wire recommendation: Input wire: Output wire: 0.5 – 2.5mm2 2 0.5 – 2.5mm AWG: 20 – 14 AWG: 20 – 14 Use: Strand / solid copper wire Wire temperature specification: 70°C minimum (>70°C) Wire material: Copper Connections: Screw type terminal COMBICON. Recommended tightening torque 0.5 to 0.7Nm (6.0lb.in.) Case material: Grey Plastic Please follow safety instruction overleaf. http://www.tracopower.com Rev: 1.0 / 1116 Safety Instructions Before installation read these instructions carefully and completely. This installation instruction cannot account for every possible condition of installation, operation or maintenance. Further information can be obtained from your local distributor’s office or from the product datasheet, which can be downloaded, from the Internet at http://tracopower.com/products/tpc.pdf. You will find additional information in our Instruction Manual, which can also be downloaded from the Internet at: http://www.tracopower.com/products/tpc_manual.pdf. The mains supply voltage connection, must be in accordance to IEC 62103, EN50178 and IEC 60364, VDE100. Before any installation, maintenance or modification work ensure that the main switch is switched off and prevented from being switched on again. Non-observance, touching of any live components or improper handling of this power supply can result in death, severe personal injury or substantial property damage. Proper and safe operation is dependent on proper storage, handling, installation and operation. Compliance with the relevant national regulations (in the USA, Europe and other countries) must be ensured. Before operation is started the following conditions must be ensured: Connection to mains supply in compliance with national regulations (VDE100 and EN50178). By use of stranded wires, all strands must be fastened in the terminal blocks. (Potential danger of contact with the case) On the Output ALL four power terminals must be used. Power supply and mains cables must be sufficiently fused. Degree of protection I to IEC536. (Protection Class I). All output wires must be rated for the power supply output current and must be connected with the correct polarity. Sufficient cooling must be ensured. Warning: Hazardous voltages and components storing a very substantial amount of energy are present in this power supply during normal operating conditions. However, these are inaccessible. Improper handling may result in an electric shock or serious burns! Do not open the power supply until at least 5 minutes after it has been disconnected from the mains on all poles. Only trained personnel may open the power supply. Do not introduce any objects into the power supply. The output voltage adjustment potentiometer may only be actuated using an insulated screwdriver. Keep away from fire and water Installation Instructions: This power supply is designed for professional indoor systems. The unit shall be mounted in an enclosure without openings in the end application. In operation the power supply must not be accessible. It may be installed and put into service by qualified personnel only. The correct mounting position for optimal cooling performance must be observed. Do not cover any ventilation holes. Leave a free space of minimum 50mm (2in.) above and below the power supply, if possible both sides should be clear for airflow and observe power derating. The internal fuse is not accessible, as it may not be replaced by the user. If this internal fuse has blown, the power supply has an internal defect and, for safety reasons, must be shipped to the local distributor. In case this internal fuse has to be replaced in the field, replace only with same type and rating of fuse for continued protection against risk of fire. Recycling: The unit contains elements that are suitable for recycling, and components that need special disposal. You are therefore requested to make sure that the power supply will be recycled at the end of its service life. Never work on the power supply if power is supplied! Risk of electric arcs and electrical shock, which can cause death, severe personal injury or substantial property damage. CAUTION: “FOR USE IN A CONTROLLED ENVIRONMENT” http://www.tracopower.com Rev: 1.0 / 1116