ASTEC APA100

Astec Integrated Power
W9959_02_DCDC_001-073_73
2/8/02
3:55 PM
Page 58
1200 Watts
Total Power:
Input Voltages:
No. of Outputs:
APA100 (PFC)
1200 Watts
85-265 VAC
Single
Electrical Specs
Input
Input Voltage
Input Frequency
Efficiency
85 to 265 Vac
50/60 Hz
92% typical (VI = 115 Vac);
94% typical (VI = 230 Vac)
Total Harmonic Distortion Less than10%
Power Factor
0.99 typical (IO = 2A);
0.97 typical (IO = 1A)
Control
Special Features
• Unity power factor
• High efficiency - up to 96%
• Universal input voltage and
frequency range
• Up to 1200W output power
• Parallelable with current sharing within 3%
• < 10% harmonic distortion
conforming to IEC555-2
• 85°C baseplate operating
temperature (no derating)
• High reliability - over 1 million
hours MTBF
• Power fail warning signal
• PLD feature
• Enable output to control AMPSS®
DC-DC converters
• 125Khz fixed Switching frequency
Power Fail Warning
Power Fail Warning Adjust
LD Enable
PFC Enable
Voltage Adjust
Clock Input (external sync)
Clock Output (int. clock)
Temperature
Monitor Output
Current Monitor Output
Storage temperature: -40°C to +105°C
Overtemperature protection: 90°C typical
MTBF: > 1 million hours (50°C baseplate)
58
America’s (USA): 1-888-41-ASTEC
10 mV/°K (2.73V = 0°C)
0 to 1.28mA (1 mA = 2.5A)
Output
Output Voltage
Current Share Accuracy
Overvoltage Protection
Power Limit
Environmental
Operating temperature (baseplate):
-20°C to +85°C (no derating)
Direct drive output to opto-isolator
205 to 355 Vdc adjustable
Direct drive output to opto-isolator
TTL compatible (low to enable)
240V to 393V
3.3 to 5.5Vp-p @ 1MHz ± 5%
4.5Vp-p typical @ 1MHz ± 0.5%
383 V typical (IO = 2A); 393 V typical
(IO = 0A)
3% typical
417 V typical
VIN=85Vac;
Pmax=750W
VIN=180Vac;
Pmax= 918W
VIN=230Vac;
Pmax= 1200W
Safety
UL
CSA
EN
VDE
CE
Europe (UK): 44 (1384) 842-211
UL 1950
CSA22.2-234
CSA22.2-950
60950
IEC950
CE Mark (LVD)
E132002
LR53 982C
20396-3336-1012
Asia (HK): 852-2437-9662
W9959_02_DCDC_001-073_73
2/8/02
3:55 PM
Page 59
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
APA100 (PFC)
Ordering Information
Part Number
Description
Notes
APA100-101
APA100-103
APA100-102
1200W Low Profile PFC Module
950W Low Profile PFC Module
1200W Low Power PFC Module
For parallel operation the total input current must be <16A rms.
Inrush current limited protection required
Designed for parallel operation where the total input
current >16A rms-requires external rail rectifiers
APA100-104
1200W Low Profile PFC Module
THERMAL BASE PLATE*
12.7 (0.50)
4 OUTPUT PINS
4 INPUT PINS
14 CONTROL PINS
31-32.
33-34.
L1
L2
Output
Control Pins
21-22. +ve
28-29. –ve
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
RSV (Reserved)
TEMP MON
C MON
C SHARE
CLK OUT
CLK IN
RSV (Reserved)
RSV (Reserved)
V ADJ
PFW ADJ
S GND
PFW
34
33
32
31
29
28
8
14
7
1
22
21
61.0 (2.40)
Input
AMPSSTM POWER MODULE
Pin Assignments
116.8 (4.60)
+ O/P
C SHARE
CLK OUT
7
1
8
14
Output to
AMPSS™ Modules
13. LD ENABLE
14. PF ENABLE
– O/P
+ O/P
C SHARE
CLK IN
7
1
8
14
– O/P
APA100-xxx
L2
+ I/P
+ O/P
1
385Vdc
8
1 + SENSE
Load
14
7
12
– SENSE
– I/P
– O/P
L1
6
+
+ O/P
Astec Integrated Power
7
85 to 265 Vac
AM80A-300L
– O/P
AM80A-300L
+ O/P
+ I/P
6
+
Power Fail Warning Adjust
7
1 + SENSE
12
– SENSE
– I/P
– O/P
www.astec.com
59