ASTEC HMFLEX

250-2600 Watts
HELIOS
Mini FLEX
Electrical Specs
2600W 48 VDC Compact Flexible Power Solution
Input
AC input voltage range
110/220VAC (86-264 VAC for 250 W,
176-264 VAC for 500 W,186-264 VAC
for 650W rectifiers)
Frequency
45 – 65 Hz
Efficiency
> 86% at full load
Power factor
0.99 (50 – 100% output load)
Total harmonic distortion
< 6.5% at loads over 50% of rated
current
Output
Special Features
• Up to 2600 W Power Output and up to 5200 W with
optional double shelves
• Front access unit.
• Operable in 110VAC or 220VAC systems
• One to four 250W/500W/650W output rectifiers
providing up to 1950W with N+1 redundancy
• Distribution: 8 fuse positions (0 to 10A each)
• Power factor correction
• Current sharing
• Standard Low Voltage Disconnect (LVD) with LVD
bypass and LVD test.
• Hot plug-in rectifier modules
• Soft switching technology
• Brackets for 1.5 or 4.75 inch depth installation
• Full complement of LED and output alarms
• Connection for battery string
• Compact dimensions
Power shelf: 19"W x 4.94"H x 13.2"D
Battery tray: 17.3"W x 7"H x 14.46"D
• CE Marking
DC output voltage range
-54.5 VDC ± 0.27 VDC (Factory
preset)
Output Current
18.35A (1000W), 36.70A (2000W),
47.71 A (2600W) @ -54.5 VDC
Maximum output power
1120 W, 2240 W, 2730 W @ power
limit. Different preset voltages avail.
Voltage regulation
± 0.5% load/line and ± 1.0%
load/line°C
Dynamic response
± 5% for 10% to 90% or 90% to 10%
load step changes
Capacitor precharge
automatic upon insertion
Voice frequency noise
<55dB rnc @ 10% load
High frequency noise
<250 mV p-p
Battery Tray - A0802970
(for 1000 W application only)
Protection
disconnect device
Batteries
Environmental
Built in 30 A circuit breaker
Designed to accommodate 30 A/h
M12V30 Marathon VRLA batteries
EMC/EMI: FCC Class B, CISPR Class B for digital devices,
Telcordia GR-1089-CORE, Class B, EN 300 386-2
Temperature: -40° to +65°C (+50°C for high altitude)
Humidity: 0 to 95% RF (non-condensing)
Acoustic noise: < 60dB for full system
Cooling: forced air, horizontal (side to side)
Safety
Shock and vibration: meets Telcordia GR-63- CORE
Fire resistance: UL 94VO, TR-NWT-000154, Sec 7.2
Voltage surge protection: meets Telcordia GR-1089
section 4.5.9
170
America’s (USA): 1-888-41-ASTEC
Rectifier:
UL1950
Power Shelf:
UL1801, CSA 22.2#950, IEC-950, VDE
Europe (UK): 44 (1384) 842-211
Asia (HK): 852-2437-9662
rev 12.01.01
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Ordering Information
HMFLEX-
-
EXAMPLE: HMFLEX- 1 - 3
Multiplier
Rectifier
Base
1
2
3
1
2
3
4
250W
500W
650W
500W
1000W
1300W
750W
1500W
1950W
1000W
2000W
2600W
750 W total power
with three 250 W rectifiers
Helios MiniFLEX includes Power Shelf, LVD, and distribution; eight 10A GMT fuses
Options:
P0917017
A080297
P0917018
P0944645
P0944646
P0944647
P0944716
P0944718
P0944719
Helios MiniFlex 23” adapter bracket kit
Battery Shelf and battery tray cable assembly to accommodate 30 A hr battery string for HMFLEX-1Battery shelf 23” adapter bracket kit
60” power cord for up to 220 VAC with Hubbel #2321AC plug
120” power cord for up to 220 VAC with Hubbel #2321AC plug
180” power cord for up to 220 VAC with Hubbel #2321AC plug
60” power cord for up to 220VAC without AC plug
120” power cord for up to 220VAC without AC plug
180” power cord for up to 220VAC without AC plug
www.astec.com
system (battery not included)
171