ASTEC AA20140

W9959_04_LP_099-133_35 2/8/02 4:15 PM Page 104
120 Watts
AA20140 Series
Total Power:
Input Voltage:
# of Outputs:
70-120 Watts
85-264 VAC
Quad
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
90-264 VAC
47-63 Hz
40 A max., cold start @ 25°C
65% typical at full load
FCC Class B conducted and radiated,
CISPR 22 Class B conducted and
radiated, EN55022 Class B
conducted and radiated, VDE 0878
PT3 Class B conducted and radiated.
0.99 typical
Power factor
Safety ground
Leakage current
Special Features
<2 mA @ 50/60 Hz, 254 VAC input
Output
Maximum power
•
•
•
•
•
•
•
•
•
Active power factor correction
EN61000-3-2 compliance
Remote sense on outputs one and two
Industry-standard 4.25” x 7” footprint
Adjustable main outputs
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
Environmental
70 W convection; 120 W with 30
CFM forced air
±5% minimum on 3.3 V and 5 V
outputs
15 ms @ 120 W load, 115 VAC input
Short circuit protection on all
outputs. Case overload protected @
110-145% above peak rating
3.3 V output: 4.25 V ±.25 V
5 V output: 6.25 V ±.75 V, 20-35%
above nominal output. Latching
type recycle AC to reset.
Compensates for 0.5 V lead drop
min. Will operate without remote
sense connected.
Operating temperature: 0° to 50°C ambient; derate
each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
20% to 90%
Vibration: 5-32 Hz sinewave .02” double amplitude
32-2 kHz sinewave 1 G peak
Safety
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF per mil std 217E: >200,000 hours at full load
and 30°C ambient conditions and full load
104
104
America’s (USA): 1-888-41-ASTEC
TUV
UL
CUL
CB
CE
Europe (UK): 44 (1384) 842-211
EN60950
UL1950
CSA 22.2-234 Level 3
Certificate and report
Mark (LVD)
9837006
E186249
E186249
DE2-002056
Asia (HK): 852-2437-9662
W9959_04_LP_099-133_35 2/8/02 4:15 PM Page 105
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
AA20140 Series
Ordering Information
Model
Output
Minimum
Maximum Load with
Maximum Load with
Number
Voltage
Load
Convection Cooling
30 CFM Forced Air
Load
AA20140
+3.3 V
+5 V
+12 V
-12 V
0A
1A
0.2 A
0A
8A
10 A
1A
0.5 A
16 A
20 A
2A
0.5 A
18 A
22 A
3A
1A
1.
2.
3.
4.
2
Peak
Regulation
1
Ripple
3
P/P (PARD)
±2%
±3%
±5%
±10%
50 mV
50 mV
120 mV
120 mV
Peak current lasting <30 seconds with a maximum 10% duty cycle.
At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Minimum loads are required.
3.75"
(95.25)
4.25"
(107.95)
Pin Assignments
Connector
GND
SK1
SK1
PIN 1
PIN 3
Neutral
Live
SK2
PIN 1-10
PIN 11
PIN 12
PIN 13
PIN 14-17
PIN 18-22
PIN 23
PIN 24
Common
+5 Sense
+3.3 V Sense
+12 V
5V
3.3 V
Return Sense
-12 V
Mating Connectors
(SK1) AC Input:
(SK2) DC Output:
1
3
6.50"
(165.10)
7.00"
(177.80)
Molex: 09-50-8031 (USA)
Molex: 09-91-03500 (UK)
PINS: 08-58-0111
Molex: Right angle
39-30-1240 or
39-29-1248
or
Vertical
39-28-1243
Astec Connector Kit #70-841-013, includes all of the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance ±.02”.
3. Warranty: 1 year
4. Weight: 1.38 lb. / .63 kg
Height is 1.6"
8.50"
(215.90)
SK2
www.astec.com
105