110 Watts LPQ110 Series Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Quad Electrical Specs Input Input range Frequency Inrush current Input current Efficiency EMI filter Special Features • • • • • • • • • Universal input High efficiency Remote sense on main output Built-in EMI filter Low output ripple Adjustable 5 V output Overvoltage protection Overload protection Adjustable floating 4th output (On LPQ112 and LPQ113) • Power fail • Optional L bracket (-B suffix) • Cover kit available LPX110-C Environmental Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C Safety ground leakage current Maximum power Adjustment range Cross regulation Hold-up time Overload protection Overvoltage protection Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions 80 W for convection; 110 W with 30 CFM forced air ±5% min. on main; 5-25 V on 4th output on LPQ112 and LPQ113 ±2% on output 1; ±3% on outputs 2, 3 & 4 20 ms @ 80 W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating 5.7-6.7 VDC on main output. Latching type, recycle AC to reset. Logic Control Power Failure Remote sense Humidity: Operating; non-condensing 5% to 95% Storage temperature: -40° to 85°C <0.5 mA @ 50/60 Hz, 264 VAC input Output Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25°C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted TTL logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Electrical Specs VDE UL CSA NEMKO CB CE 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 Certificate and report Mark (LVD) 11774-3336-1245 (LC #84997) E132002 LR53982C P94102464 1423, 1424, 1425 rev 12.10.03 102 Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 AMERICAS EUROPE ASIA 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30 CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 LPQ112 5V 12 V -12 V ±5-25 V 2A 0A 0A 0A 9A 4.5 A 0.7 A 2.5 A 11 A 5A 1.0 A 3A 15 A 9A 1.5 A 3.5 A ±2% ±3% ±5% ±3% 50 mV 120 mV 120 mV 240 mV, max. LPQ113 5V 15 V -15 V ±5-25 V 2A 0A 0A 0A 9A 4.5 A 0.7 A 2.5 A 11 A 5A 1.0 A 3A 15 A 9A 1.5 A 3.5 A ±2% ±3% ±5% ±3% 50 mV 150 mV 150 mV 240 mV, max. LPQ114 5V 12 V -12 V 24 V 2A 0A 0A 0.5 A 9A 4.5 A 0.7 A 3.5 A 11 A 5A 1.0 A 4.5 A 15 A 9A 1.5 A 5A ±2% ±3% ±5% +10 / -5% 50 mV 120 mV 120 mV 240 mV LPQ110 Series Ordering Information 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. 4th O/P adjustable 5 to 25 V, factory set at 5 V. 5. Minimum loads are required. Note: -B suffix added to model number indicates L bracket option. -B Bracket Connector LPQ112 LPQ113 LPQ114 SK1-1 SK1-3 SK1-5 GND Neutral Line GND Neutral Line GND Neutral Line SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK2-7 SK2-8 SK2-9 SK2-10 SK2-11 SK2-12 SK201-1 SK201-2 SK202-1 SK202-2 +5 V +5 V +5 V Common Common Common Common +12 V +12 V -12 V +5-25 V -5-25 V +sense -sense POK GND +5 V +5 V +5 V Common Common Common Common +15 V +15 V -15 V +5-25 V -5-25 V +sense -sense POK GND +5 V +5 V +5 V Common Common Common Common +12 V +12 V -12 V +24 V Common +sense -sense POK GND Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ± 0.02” 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting holes M1 and M2 should be grounded for EMI purposes. 5. Mounting hole M1 is safety ground connection. 6. L bracket mounting (6-32) maximum insertion depth is .20” (5). 7. Warranty: 1 year 8. Weight: 1.25 lb./0.57 kg 2.5" (63.5) 6.4" (162.6) 7.3" (185.5) 2.2" (56) 0.86" (21.8) 5.9" (150.0) 0.25" (6.35) M2 4.0" (101.6) 5V O/P ADJ Mating Connectors AC Input: Molex 09-50-8051 (USA) 09-91-0500 (UK) PINS: 08-58-0111 DC Outputs: Molex 09-50-8121 (USA) 09-91-1200 (UK) PINS: 08-58-0111 Remote sense/Power fail: Molex 22-01-1022 (USA) 22-01-1023 (UK) PINS: 08-50-0114 Astec Connector Kit #70-841-008, includes all of the above. #6-32 PEM 6 places 4.28" (108.6) 3.5" (88.9) 4th O/P ADJ 1 1 2 3 4 5 6 7 8 9 10 11 12 3 SK 1 6.5" (165.1) 0.25" (6.35) 7.0" (177.8) SK 201 (+S) 1 (-S) 2 SK 202 (POK) 1 2 SK 2 Pin Assignments GND N L M1 0.156" (4) DIA (4 places) 1.80" (45.7) 0.12" (3) www.astecpower.com 103