ETC NTQ123

Net Series
NTQ123
70 - 120 Watts
Total Power
70 - 120 Watts
Input Voltages
85 - 264VAC
# of Outputs
Quad
S P E C I A L F E AT U R E S
•
•
•
•
•
•
•
•
•
•
Active power factor correction
EN61000-3-2 compliance
Remote sense on outputs
one and two
Power fail and remote inhibit
Single wire current sharing on
outputs one and two
Adjustable main outputs
Built-in Class B EMI filter
Overvoltage protection
Overload protection
Thermal overload protection
E L E C T R I C A L S P E C I F I C AT I O N S
Input
Input range ........................... 85-264 VAC
Frequency ............................ 47-63 Hz
Inrush current ....................... 38 A max., cold start @ 25°C
Efficiency .............................. 65% typical at full load
EMI filter ............................... FCC Class B conducted and radiated,
CISPR 22 Class B conducted and radiated,
EN55022 Class B conducted and radiated,
VDE 0878 PT3 Class B conducted and
radiated.
Power factor ......................... 0.99 typical
Safety ground
Leakage current ................... <0.75 mA @ 50/60 Hz, 264 VAC input
E N V I R O N M E N TA L
Output
Operating temperature: 0° to 50°C ambient;
derate each output at 2.5% per degree from
50° to 70°C
Maximum power ................... 70 W convection,
120 W with 30 CFM forced air
Adjustment range ................. ±5% minimum on outputs one and two
Hold-up time ......................... 20 ms @ 120 W load, 120 VAC input
Overload protection .............. Short circuit protection on all outputs. Case
overload protected @ 110-145% above
peak rating
Overvoltage protection ......... 3.3 V and 5 V output: 20% to 35%
above nominal output
Electromagnetic susceptibility: Designed to meet
EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ± .04% per °C
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
Logic Control
Power failure ........................ TTL logic signal goes high 100-500 msec
after 5 V output; it goes low at least 4 msec
before loss of regulation
Remote Inhibit ...................... Requires an external TTL Signal to inhibit
outputs
Remote sense ...................... Compensates for 0.5 V lead drop minimum,
will operate without remote sense connected. Reverse connection protection.
SAFETY
VDE
UL
CSA
NEMKO
BABT
CB
CE
42
USA: 1-888-41-ASTEC
Europe (UK): 01384-842211
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE
(74-sec) 203
EN60950/EN41003
Certificate and report
Mark (LVD)
Asia (HK): 852-2437-9662
21310-3336-0004
E186249
LR109492C
P98100870
608497
5009
ASTEC ASIA
6F., China Dyeing Works Building
382-392 Castle Peak Road
Tsuen Wan, N.T., Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
ASTEC EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 01384-842211
Facsimile: 01384-843355
ASTEC AMERICA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
NTQ123
+3.3 V
+5 V
+12 V
-12 V
0A
2A
0A
0A
14 A
12.5 A
1A
0.5 A
25 A
24 A
2A
1A
28 A
28 A
4A
1.5 A
±2%
±2%
±3%
±3%
50 mV
50 mV
120 mV
120 mV
1.
2.
3.
4.
Peak current lasting <30 seconds with a maximum 10% duty cycle.
At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Minimum loads are required. In parallel minimum loads are 2.5 A on the 5 V output and 1 A on the 3.3 V output.
M 3.5
(3 places)
MAIN OUTPUTS
+3.3V
COMMON
+5V
SK6
Connector
54321
SK5
123
678910
#6-32 UNC (8 places)
M3 (4 places)
.5625
SK4 SK3 SK2 VR401 VR403
5V adj
NTQ123
PIN ASSIGNMENTS
D R AW I N G S
LOW
Low Power
Model
Number
P o w e r
O R D E R I N G I N F O R M AT I O N
SK1
PIN 1
PIN 3
PIN 5
Ground
Neutral
Live
SK5
PIN 1
PIN 2
PIN 3
+12 V
Common
-12 V
SK6
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
+5 V Sense
-5 V Sense
+ Inhibit
- Inhibit
Power Fail
COMMON
5 V SWP
+3.3 V + Sense
-3.3 V Sense
3.3 V SWP
3.3V adj
5.5
(139.7)
6.5
4.7
(119.6) (165.1)
7.0
(177.8)
M AT I N G C O N N E C T O R S
(SK1) AC Input:
5 33 115 3 1
SK1
SK4
4.00
(101.6)
SK2,3,4:
.75 (19.0)
1.5
(38.1)
(SK5) ±12V
Molex: 09-50-8051 (USA)
Molex: 09-91-0500 (UK)
PINS: 08-58-0111
Molex BB-124-08
Molex:09-50-8031 (USA)
Molex: 09-91-0300 (UK)
PINS: 08-58-0111
(SK6) Control Signals: Molex: 90142-0010
PINS: 90119-2110
or
Amp: 87977-3
PINS: 87309-8
2.5
(63.5)
Astec Connector Kit #70-841-004
NOTES
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance ±.02”.
3. Remote inhibit requires an external 5 V @ 10 mA
to activate
4. Mounting maximum insertion depth is 0.15”.
5. Warranty: 1 year
6. Weight: 1.38 lb. / .63 kg
Power Fax: 760-930-0881
Doc No:1040 • REV 5.26.99
43