du1p0 I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters series Low Cost 1 Watt in SIP Package Unregulated Outputs Input/Output Isolation up to 3KVDC UL 94-V0 Non-Conductive Case Internal Input & Output Filters Unit measures 0.24”W x 0.77”L x 0.4”H Model Number Output Voltage Output Amps Input Range Efficiency Max I.P. Current Max Load Capacitance SINGLE OUTPUT DU1P0-05S05(N) 5 VDC DU1P0-12S05(N) DU1P0-15S05(N) DU1P0-24S05(N) DU1P0-05S12(N) 12 VDC DU1P0-12S12(N) DU1P0-15S12(N) DU1P0-24S12(N) DU1P0-05S15(N) 15 VDC DU1P0-12S15(N) DU1P0-15S15(N) DU1P0-24S15(N) 200 200 200 200 83 83 83 83 67 67 67 67 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 77% 77% 73% 72% 82% 82% 79% 78% 81% 79% 80% 78% 274mA 114mA 97mA 61mA 255mA 106mA 89mA 56mA 261mA 112mA 88mA 57mA 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF 6.2uF DUAL OUTPUT DU1P0-05D05(N) +/-5 VDC DU1P0-12D05(N) DU1P0-15D05(N) DU1P0-24D05(N) DU1P0-05D12(N) +/-12 VDC DU1P0-12D12(N) DU1P0-15D12(N) DU1P0-24D12(N) DU1P0-05D15(N) +/-15 VDC DU1P0-12D15(N) DU1P0-15D15(N) DU1P0-24D15(N) +/-100 +/-100 +/-100 +/-100 +/-42 +/-42 +/-42 +/-42 +/-33 +/-33 +/-33 +/-33 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 4.5-5.5 VDC 10.8-13.2 VDC 13.5-16.5 VDC 21.6-26.4 VDC 78% 77% 75% 75% 82% 81% 80% 78% 81% 82% 80% 79% 270mA 114mA 94mA 59mA 258mA 109mA 88mA 57mA 257mA 106mA 87mA 55mA 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF 3.0uF Note - (N) Denotes that there is an optional 3000VDC Input to Output Isolation version available for the DU1P0 family of products. To order a DU1P0 product with the optional 3000VDC Isolation, simply add an “N” to the end of the standard Part Number. For example DU1P0-05S05N. Order On-Line! WWW.ASTRODYNE.COM astrodyne.com 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 du1p0 I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters INPUT SPECIFICATIONS Input Voltage Ranges: Input Current Input Filter ENVIRONMENTAL SPECIFICATIONS 5 VDC Nominal 4.5-5.5 VDC 12 VDC Nominal 10.8-13.2 VDC 15 VDC Nominal 13.5-16.5 VDC 24 VDC Nominal 21.6-26.4 VDC (Nom Vin, Full Load) See Selection Chart Capacitor OUTPUT SPECIFICATIONS Voltage and Current Load Regulation (Note 1) 20% - FL Line Regulation (HL-LL) Temperature Coefficient Ripple/Noise(Single/Dual) Voltage Accuracy Short Circuit Protection Minimum Load (Note 1) Max. Load Capacitance series Oper. Temperature Storage Temperature Relative Humidity MTBF (Note 2) Thermal Shock Vibration -25 to +85°C(See Derate Curve) -55 to +105°C * 5% to 95% RH * 1.471 MHrs MIL-STD-810D 10-55Hz, 10G, 30 Minutes along X, Y, and Z PHYSICAL SPECIFICATIONS See Selection Chart +/- 10% on 5V output +/- 8% on all others +/- 1.3%/1% of Vin +/-0.1%/°C max. 100mV Pk-Pk, typ +/-5%, max 1 Second max 10% of FL Min Vin & Resitive Load See Selection Chart Dimensions Case Material Construction Weight 0.77 x 0.24 x 0.40” UL 94-V0 Non-Conductive Black Plastic Fully Encapsulated (UL94-V0) 2g (0.071oz) NOTES 1) A Minimum 10% Load is required to maintain regulation 2) BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40°C. (Ground fixed and controlled environment) GENERAL SPECIFICATIONS Input-Out Isolation Efficiency (Nom I/P & FL) Switching Frequency Isolation Resistance Isolation Capacitance Safety 1000VDC; (3000VDC suffix-N) See Selection Chart 60Khz 10000 M Ohms 30pF, max. UL, TUV, CB, CE All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 du1p0 I s o l a t e d a n d U n r egulated 1 WATT Modular DC/DC Converters series MECHANICAL DIMENSIONS STANDARD MODELS 0.77(19.6) 0.016(0.4) FRONT VIEW 0.40(10.2) 0.01x 0.02 ( 0.25 x 0.5) Rectangular Pin 0.10(2.54) 0.14(3.6) 0.085(2.16) 0.24(6.1) 0.20(5.08) 1 BOTTOM VIEW 2 4 5 6 7 Single OutputsDual Outputs 1 2 4 5 6 7 + Input - Input - Output NC + Output No Pin + Input - Input - Output Common + Output No Pin 0.053(1.35) All dimensions in inches(mm) Tolerance : x.xx±0.02(x.x±0.5) x.xxx±0.01(x.xx±0.25) Pin pitch tolerance ±0.014(0.35) OUTPUT DERATING CURVE OUTPUT POWER (%) Pin # “N” MODELS Pin # Single OutputsDual Outputs 1 2 4 5 6 7 + Input - Input No Pin - Output NC + Output + Input - Input No Pin - Output Common + Output 100 75 50 Nature convection 25 0 -40 -25 -10 0 50 60 70 80 90 100 AMBIENT TEMPERATURE (ºC) WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181