Specification Type : Issue: 01 Date: 2003-12-22 AX52HSL Quartz Crystal Unit in Hyper Slim-Line (HSL) package Parameter Frequency range Crystal cut Frequnecy vs.Overtone Adjustment tolerance @ 25°C Load capacitance CL Frequency stability vs. temperature long term (aging) Resonance resistance Rr (typical values) Shunt capacitance C0 Drive level Drive level dependence (DLD) Unwanted responses min. typ. 20 max. Unit 230 MHz AT 20 MHz ~ 40 MHz 50 MHz ~ 120 MHz 80 MHz ~ 200 MHz 120 MHz ~ 230 MHz ±5 ~ ±50 10 pF ~ 100 pF, Series ±5 ppm ±10 ppm 0°~+50°C -10°~+60°C ±5 35 Ω 30 Ω 70 Ω 150 Ω 7 100 Condition Optimized for turn-over temperature of 25° FUND 3rd OT 5th OT 7th OT ppm see Ordering Code 1 see Ordering Code 2 see Ordering Code 3 ppm FUND 3rd OT 5th OT 7th OT pF µW per year @ +55°C IEC 60444-6 > 2·Rr ≤ 100 MHz >1.5·Rr > 100 MHz 500 -40 +85 -55 +105 HC-52/HSL 1.5 max. 4.8 max. Frequency (MHz) bulk 100 V DC Insulation resistance MΩ °C Operable temperature range °C Storage temperature range IEC 60122-3 or 61837 Enclosure (see drawing) mm Flange width mm Can height Side 1 marking IEC 60286-3 Packing Notes: 1. Terminology and test conditions are according to IEC standard IEC60122-1, unless otherwise stated 2. Measurement technique according to IEC 60444-5 or equivalent Ordering Code: Adjustment Load Frequency stability vs. Frequency tolerance capacitance temperature ppm Code pF Code ppm range Code in MHz AX52HSL ±5 05 10 10 ±5 0°~+50°C 05 any ±10 10 20 20 ±10 -10~+60°C 10 ±25 25 30 30 ±15 -20~+70°C 15 ±50 50 50 50 100 100 S* S *Series resonance: “S” Example: AX52HSL 05-30-10-52,500 MHz Model (Specification) GmbH & Co. KG Buchfinkenweg 8 D-74931 Lobbach Germany page 1(2) wwwAXTAL.com fon: +49 (6226) 9719689 fax: +49 (6226) 970133 E-mail: [email protected] Enclosure drawing (in mm) Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests 2-17 IEC 61178-1 clause ... 4.5 4.6 4.8.2 Solderability Resistance to soldering heat Shock 2-20 4.8.3 2-27 4.8.8 Free fall 2-32 4.8.9 Vibration, sinusoidal Endurance tests - ageing - extended aging 2-6 4.8.7 4.9.1 4.9.2 Test conditions Enclosure styles as in IEC 60122-3, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Test Ea, test conditions on request Test Ed procedure 1, test conditions on request Test Fc, test conditions on request 30 days @ 85°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Buchfinkenweg 8 D-74931 Lobbach Germany page 2(2) wwwAXTAL.com fon: +49 (6226) 9719689 fax: +49 (6226) 970133 E-mail: [email protected]