AXTAL AX52HSL

Specification
Type :
Issue: 01
Date: 2003-12-22
AX52HSL
Quartz Crystal Unit in Hyper Slim-Line (HSL) package
Parameter
Frequency range
Crystal cut
Frequnecy vs.Overtone
Adjustment tolerance @ 25°C
Load capacitance CL
Frequency stability
vs. temperature
long term (aging)
Resonance resistance Rr (typical values)
Shunt capacitance C0
Drive level
Drive level dependence (DLD)
Unwanted responses
min.
typ.
20
max. Unit
230
MHz
AT
20 MHz ~ 40 MHz
50 MHz ~ 120 MHz
80 MHz ~ 200 MHz
120 MHz ~ 230 MHz
±5 ~ ±50
10 pF ~ 100 pF, Series
±5 ppm
±10 ppm
0°~+50°C
-10°~+60°C
±5
35 Ω
30 Ω
70 Ω
150 Ω
7
100
Condition
Optimized for turn-over
temperature of 25°
FUND
3rd OT
5th OT
7th OT
ppm
see Ordering Code 1
see Ordering Code 2
see Ordering Code 3
ppm
FUND
3rd OT
5th OT
7th OT
pF
µW
per year @ +55°C
IEC 60444-6
> 2·Rr
≤ 100 MHz
>1.5·Rr
> 100 MHz
500
-40
+85
-55
+105
HC-52/HSL
1.5 max.
4.8 max.
Frequency (MHz)
bulk
100 V DC
Insulation resistance
MΩ
°C
Operable temperature range
°C
Storage temperature range
IEC 60122-3 or 61837
Enclosure (see drawing)
mm
Flange width
mm
Can height
Side 1
marking
IEC 60286-3
Packing
Notes:
1. Terminology and test conditions are according to IEC standard IEC60122-1, unless otherwise stated
2. Measurement technique according to IEC 60444-5 or equivalent
Ordering Code:
Adjustment
Load
Frequency stability vs. Frequency
tolerance
capacitance temperature
ppm Code pF Code ppm
range
Code in MHz
AX52HSL
±5
05
10
10
±5 0°~+50°C 05
any
±10
10
20
20 ±10 -10~+60°C 10
±25
25
30
30 ±15 -20~+70°C 15
±50
50
50
50
100 100
S*
S
*Series resonance: “S”
Example: AX52HSL 05-30-10-52,500 MHz
Model (Specification)
GmbH & Co. KG
Buchfinkenweg 8
D-74931 Lobbach
Germany
page 1(2)
wwwAXTAL.com
fon: +49 (6226) 9719689
fax: +49 (6226) 970133
E-mail: [email protected]
Enclosure drawing (in mm)
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
IEC 61178-1
clause ...
4.5
4.6
4.8.2
Solderability
Resistance to
soldering heat
Shock
2-20
4.8.3
2-27
4.8.8
Free fall
2-32
4.8.9
Vibration,
sinusoidal
Endurance tests
- ageing
- extended aging
2-6
4.8.7
4.9.1
4.9.2
Test conditions
Enclosure styles as in IEC
60122-3, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, test conditions on
request
Test Ed procedure 1, test
conditions on request
Test Fc, test conditions on
request
30 days @ 85°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Buchfinkenweg 8
D-74931 Lobbach
Germany
page 2(2)
wwwAXTAL.com
fon: +49 (6226) 9719689
fax: +49 (6226) 970133
E-mail: [email protected]