AXTAL AXLE208

Issue: 01
Specification
AXLE208
Oscillator type : TCXO in CO15 package
Parameter
Frequency range
Frequency stability
vs. temperature
vs. supply voltage variation
vs. load change
long term (aging) per year
Frequency adjustment range
Mechanical (internal trimmer)
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Amplitude
Supply voltage VS
Current consumption (Note 3)
Storage temperature range
Enclosure (see drawing)
Marking
min.
typ.
6
1
max.
Unit
Condition
190
800
MHz
MHz
ppm
ppm
ppm
ppm
ppm
(Clipped) Sinewave
HCMOS
See tables 1 & 2
ppm
ppm
V
V
Option 1 = blank
Option 1 = “V”
Option 2 = “3”
Option 2 = “5”
± 0.5 ppm to ± 5 ppm
± 0.1
± 0.3
± 0.2
±1
±3
±5
0.15
0.5
1.65
2.5
positive
100
Date:2008-05-07
3.15
4.5
± 10 %
@+40°C
kΩ
Sine wave
Clipped Sine wave
HCMOS
50 Ω
10 kΩ || 10 pF
15 pF
0
dBm
+10
dBm
0.8
V p-p
1.0
V p-p
According to relevant Logic Standard
3.15
3.3
3.45
V
4.75
5.0
5.25
V
12 ~ 30
mA
2 ~ 30
mA
15 ~ 50
mA
-45
+90
°C
20.3 x 20.3 x 5.3 max.
mm
AXLE208
Freq
wwAXPyy
Palette
Lead(Pb) -free
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
Option 3 = “S” / 3.3 V
Option 3 = “S” / 5.0 V
Option 3 = “C” / 3.3 V
Option 3 = “C” / 5.0 V
Option 3 = “H”
Option 2 = “3”
Option 2 = “5”
Option 3 = “S”
Option 3 = “C”
Option 3 = “H”
IEC 60679-3 CO-15
Specification
Frequency
ww=week, yy=year
Packing
Construction
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. All combinations of options might not be available. Please consult factory
3. Depending on frequency and supply voltage
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXLE208
page 1(2)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Frequency Stability over Temperature
Table 1
Code4 Stability
05
± 0.5
10
± 1.0
15
± 1.5
20
± 2.0
25
± 2.5
30
± 3.0
35
± 3.5
50
± 5.0
Table 2
Lower
Temperature
Code5 Temp/°C
0
0
1
-10
2
-20
3
-30
4
-40
Upper Temperature
Code5
A
B
C
D
E
F
Temp/°C
+50
+60
+70
+75
+80
+85
Ordering Code:
Part number
AXLE208
Option 1
Option 2
Option 3
Option 4
Option 5
EFC
Supply Voltage
Output
Stability
Temp. range
_ or “V”
5 or 3
S, C, H
See tables 1 & 2
Example: AXLE208V-5-S-10-3D
Enclosure drawing
Pin connections
Pin # Symbol
Function
1
N.C. or VC No Connection or Control
Voltage (EFC)
2
RF OUT RF Output
3
Vs
Supply Voltage
4
GND
Ground
5
GND
Ground
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXLE208
page 2(2)
ww.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836