Issue: 01 Date: 2005-02-01 Specification AXMW8596 Oscillator type : Crystal Controlled Microwave Oscillator Parameter Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating frequency range (steady state) medium term (aging) over 24 hours Frequency selection Electronic Frequency Control RF output Signal waveform Load Load VSWR Output Power Output Power Variation Spurious Outputs (Note 1) min. typ. max. 8.5 9.6 6 frequencies within 4% Storage temperature range Enclosure L x W x H (see drawing) Weight Packing ESD Sensitivity Condition GHz -50 -100 50 100 ppm ppm ppm @25°C -40°~+70°C -1 1 ppm @ constant temp. By grounding of appropriate selection pin SINUS 50 Note 2 Ohm 1.5 50 2 3 2 50 90 65 AM Noise (Note 1) FM Noise (Note 1) Vibration Sensitivity Supply voltage VS Current consumption (steady state) Power line Ripple Noise (pk-pk) Relative Humidity Unit 27.5 28.0 -55 -90 -75 -68 10 28.5 600 500 80 100 +85 100 x 70 x 30 TBD mW dB dB dB dB dBc dBc dBc Hz / g V mA mV % % °C mm gram 0°C ~ +70°C -30°C ~ +70°C between 6 frequencies Fc ± 5 MHz Outside fc ± 5 MHz fc ± 30 MHz ~60 MHz elsewhere fc ± 30 MHz ~60 MHz See graph 1 50 Hz ~ 200 MHz Continuous During warm-up 95% R.H. bulk 1500 V HBM as in IEC 610004-2 Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Channel selection by connecting ground (pin 7) to one of the 6 pins in Viking connector VR7/4AB13 The six nominated frequencies to be determined by the purchasing-order GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXMW 8596 page 1(5) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing: Pin connections: Mounting plate: VR7/4AB13 connector: Pin # Symbol Function 1 CH1 Channel 1 select 2 CH2 Channel 2 select 3 CH3 Channel 3 select 4 CH4 Channel 4 select 5 CH5 Channel 5 select 6 CH6 Channel 6 select 7 Ground SMA Connector: RF Output BNC Connector : VS Supply Voltage Marking: AXMW8596 AXTAL ww/xx & serial number Environmental conditions: Vibration : Specification must be met under the vibration conditions of the chart below (Graph 1). Shock : Half Sine 15 g, 11 ms in 3 mutually perpendicular axes. No damage. Shock not applied to short term stability requirements GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany AXMW 8596 page 2(5) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Typical spectrum drawing 1: Typical spectrum drawing 2: * RBW 10 kHz * VBW 50 Hz Ref 20 dBm Att 45 dB SWT 8 s 20 A 10 1 AP CLRWR 0 -10 -20 -30 -40 -50 -60 -70 -80 Center 9.07 GHz AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach 200 kHz/ Span 2 MHz AXMW8596 page 3(5) www.axtal.com [email protected] fon: +49 6261 939834 fax: +49 6261 939836 Ref 20 dBm Att RBW 20 kHz VBW 2 kHz SWT 50 ms 45 dB Delta 2 [T1 PHN] -91.37 dBc/Hz 99.358974360 kHz 1 20 Marker 1 [T1 FXD] 17.66 dBm 9.015004397 GHz PHN 17.616 dBm 10 1 SA CLRWR A 0 -10 -20 -30 2 -40 -50 -60 -70 PHN -80 Center 9.015006 GHz 100 kHz/ Span 1 MHz RBW 3 MHz Ref 20 dBm Att 45 dB VBW 300 kHz SWT 155 ms Marker 1 [T1 ] -39.28 dBm 500.000000000 MHz 20 A 10 1 AP CLRWR 0 -10 -20 -30 1 -40 -50 -60 -70 -80 Center 13.25 GHz AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach 2.65 GHz/ Span 26.5 GHz AXMW8596 page 4(5) www.axtal.com [email protected] fon: +49 6261 939834 fax: +49 6261 939836 Typical PLL settling time during switch from channel 1 to channel 6: Typical PLL settling time during switch from channel 6 to channel 1: Typical PLL settling time during switch from channel 2 to channel 3: AXTAL GmbH & Co. KG Wasemweg 5 D-74821 Mosbach AXMW8596 page 5(5) www.axtal.com [email protected] fon: +49 6261 939834 fax: +49 6261 939836