AXTAL AXMW8596

Issue: 01
Date: 2005-02-01
Specification
AXMW8596
Oscillator type :
Crystal Controlled Microwave Oscillator
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating frequency
range (steady state)
medium term (aging) over 24 hours
Frequency selection
Electronic Frequency Control
RF output
Signal waveform
Load
Load VSWR
Output Power
Output Power Variation
Spurious Outputs (Note 1)
min.
typ.
max.
8.5
9.6
6 frequencies within 4%
Storage temperature range
Enclosure L x W x H (see drawing)
Weight
Packing
ESD Sensitivity
Condition
GHz
-50
-100
50
100
ppm
ppm
ppm
@25°C
-40°~+70°C
-1
1
ppm
@ constant temp.
By grounding of appropriate
selection pin
SINUS
50
Note 2
Ohm
1.5
50
2
3
2
50
90
65
AM Noise (Note 1)
FM Noise (Note 1)
Vibration Sensitivity
Supply voltage VS
Current consumption (steady state)
Power line Ripple Noise (pk-pk)
Relative Humidity
Unit
27.5
28.0
-55
-90
-75
-68
10
28.5
600
500
80
100
+85
100 x 70 x 30
TBD
mW
dB
dB
dB
dB
dBc
dBc
dBc
Hz / g
V
mA
mV
%
%
°C
mm
gram
0°C ~ +70°C
-30°C ~ +70°C
between 6 frequencies
Fc ± 5 MHz
Outside fc ± 5 MHz
fc ± 30 MHz ~60 MHz
elsewhere
fc ± 30 MHz ~60 MHz
See graph 1
50 Hz ~ 200 MHz
Continuous
During warm-up
95% R.H.
bulk
1500
V
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Channel selection by connecting ground (pin 7) to one of the 6 pins in Viking connector VR7/4AB13
The six nominated frequencies to be determined by the purchasing-order
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXMW 8596
page 1(5)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing:
Pin connections:
Mounting plate:
VR7/4AB13 connector:
Pin # Symbol Function
1
CH1
Channel 1 select
2
CH2
Channel 2 select
3
CH3
Channel 3 select
4
CH4
Channel 4 select
5
CH5
Channel 5 select
6
CH6
Channel 6 select
7
Ground
SMA Connector: RF Output
BNC Connector : VS Supply Voltage
Marking: AXMW8596
AXTAL ww/xx & serial number
Environmental conditions:
Vibration :
Specification must be met under the vibration conditions of the chart below (Graph 1).
Shock :
Half Sine 15 g, 11 ms in 3 mutually perpendicular axes. No damage. Shock not applied to
short term stability requirements
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXMW 8596
page 2(5)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Typical spectrum drawing 1:
Typical spectrum drawing 2:
* RBW 10 kHz
* VBW 50 Hz
Ref
20 dBm
Att
45 dB
SWT 8 s
20
A
10
1 AP
CLRWR
0
-10
-20
-30
-40
-50
-60
-70
-80
Center
9.07 GHz
AXTAL GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
200 kHz/
Span 2 MHz
AXMW8596
page 3(5)
www.axtal.com
[email protected]
fon: +49 6261 939834
fax: +49 6261 939836
Ref
20 dBm
Att
RBW 20 kHz
VBW 2 kHz
SWT 50 ms
45 dB
Delta 2 [T1 PHN]
-91.37 dBc/Hz
99.358974360 kHz
1
20
Marker 1 [T1 FXD]
17.66 dBm
9.015004397 GHz
PHN 17.616 dBm
10
1 SA
CLRWR
A
0
-10
-20
-30
2
-40
-50
-60
-70
PHN
-80
Center 9.015006 GHz
100 kHz/
Span 1 MHz
RBW 3 MHz
Ref
20 dBm
Att
45 dB
VBW 300 kHz
SWT 155 ms
Marker 1 [T1 ]
-39.28 dBm
500.000000000 MHz
20
A
10
1 AP
CLRWR
0
-10
-20
-30
1
-40
-50
-60
-70
-80
Center
13.25 GHz
AXTAL GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
2.65 GHz/
Span 26.5 GHz
AXMW8596
page 4(5)
www.axtal.com
[email protected]
fon: +49 6261 939834
fax: +49 6261 939836
Typical PLL settling time during switch from channel 1 to channel 6:
Typical PLL settling time during switch from channel 6 to channel 1:
Typical PLL settling time during switch from channel 2 to channel 3:
AXTAL GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
AXMW8596
page 5(5)
www.axtal.com
[email protected]
fon: +49 6261 939834
fax: +49 6261 939836