AXTAL AXE20

Issue: 01
Date: 2005-06-20
Specification
AXE20
Oscillator type :
Crystal Oscillator, low jitter, in double-sealed DIL14
package (crystal resonator in hermetically sealed UM-1/HC-52/U)
Parameter
Frequency range
min.
typ.
1
1
Standard frequencies
Frequency stability
Overall stability (Note 2)
operating temperature range (Note 3)
long term (aging)
RF output
Signal waveform
Load
Rise & decay time
Symmetry (duty cycle)
Start-up time
Supply voltage VS
Current consumption (steady state)
max.
Unit
Condition
150
133
MHz
MHz
VS = 5 V
VS = 3.3 V
ppm
ppm
ppm
°C
°C
°C
ppm/year
Option I = “100”
Option I = “50”
Option I = “25”
Option II = “A”
Option II = “B”
Option II = “C”
@ 40°C
pF
ns
%
ms
V
@ VS/2
± 100
± 50
± 25
+70
+70
+85
±2
0
-20
-40
HCMOS
15
5
40
60
10
3.15
3.3
3.45
4.75
5.0
5.25
25
45
-45
+90
-55
+125
20.7x13.1x5.5 max.
5
Tube
1500
mA
mA
°C
°C
mm
gram
Option III = “33”
Option III = ”50”
Option III = “33”
Option III = ”50”
Operable temperature range
Storage temperature range
IEC 60679-3 CO-02
Enclosure (see drawing)
Weight
IEC 60286-3
Packing
V
HBM, IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
2. Other stabilities on request
3. Other operating temperature ranges on request
Ordering Code:
Model (Specification) Option I Option II
AXE20
100
A
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
Option III Frequency [MHz]
50
12.345678
AXE20
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
N.C.
7
GND
8
RF OUT
14
Vs
Function
Not connected
Ground
RF Output
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 8
D-74821 Mosbach
Germany
AXE20
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]