Issue: 01 Date: 2005-06-20 Specification AXE20 Oscillator type : Crystal Oscillator, low jitter, in double-sealed DIL14 package (crystal resonator in hermetically sealed UM-1/HC-52/U) Parameter Frequency range min. typ. 1 1 Standard frequencies Frequency stability Overall stability (Note 2) operating temperature range (Note 3) long term (aging) RF output Signal waveform Load Rise & decay time Symmetry (duty cycle) Start-up time Supply voltage VS Current consumption (steady state) max. Unit Condition 150 133 MHz MHz VS = 5 V VS = 3.3 V ppm ppm ppm °C °C °C ppm/year Option I = “100” Option I = “50” Option I = “25” Option II = “A” Option II = “B” Option II = “C” @ 40°C pF ns % ms V @ VS/2 ± 100 ± 50 ± 25 +70 +70 +85 ±2 0 -20 -40 HCMOS 15 5 40 60 10 3.15 3.3 3.45 4.75 5.0 5.25 25 45 -45 +90 -55 +125 20.7x13.1x5.5 max. 5 Tube 1500 mA mA °C °C mm gram Option III = “33” Option III = ”50” Option III = “33” Option III = ”50” Operable temperature range Storage temperature range IEC 60679-3 CO-02 Enclosure (see drawing) Weight IEC 60286-3 Packing V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated 2. Other stabilities on request 3. Other operating temperature ranges on request Ordering Code: Model (Specification) Option I Option II AXE20 100 A GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany Option III Frequency [MHz] 50 12.345678 AXE20 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections Pin # Symbol 1 N.C. 7 GND 8 RF OUT 14 Vs Function Not connected Ground RF Output Supply Voltage Environmental conditions Test IEC 60068 Part ... Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60679-1 clause ... 4.3 2-17 4.6.2 2-20 2-58 4.6.3 2-27 4.6.8 Bump* 2-29 4.6.6 Free fall* 2-32 4.6.9 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Vibration, sinusoidal* 2-6 4.6.7 Rapid change of temperature Dry heat 2-14 4.6.5 2-2 4.6.14 Damp heat, cyclic* 2-30 4.6.15 Cold 2-1 4.6.16 Climatic sequence* 1-7 4.6.17 Damp heat, steady state* Endurance tests - ageing - extended aging 2-3 4.6.18 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany AXE20 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]