AXTAL AXIOM50

Issue: 01
Specification
AXIOM50
Oscillator type :
VHF OCXO - Ultra low noise
Parameter
min.
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range
Operating temperature range
vs. supply voltage variation
vs. load change
Long term stability per day
Long term stability (aging rate)
Frequency adjustment range
Mechanical Frequency Control
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Load
Output amplitude
Harmonics
Sub-harmonics
Non-harmonics
Phase Noise L(f)
Warm-up time @ +25°C
Supply voltage VS
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range
Operable temperature range
Storage temperature range
Enclosure (see drawing)
Weight
Packing
ESD Sensitivity
typ.
max.
100.000 / 120.000
Unit
Date: 2008-01-25
Condition
MHz
± 200
± 500
± 500
ppb
ppb
steady state
± 500
+70
± 20
± 20
±2
± 1000
°C
ppb
ppb
ppb/day
ppb/ year
Vs ± 5%, within 10 min.
± 5%
After 30 days of
continuous operation
-20
ppm
ppm
V
N.A.
N.A.
%
kΩ
Sine wave
50
+13
+11
+15
-30
N.A.
-80
-90
-120
-150
-165
-165
3
12.6
100
300
-32
+80
-40
+85
-55
+105
51x51x20.5max.
60
Palette
1000
11.4
12
Ω
dBm
dBc
dBc
dBc
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
min
V
mA
mA
°C
°C
°C
mm
gram
V
± 10 %
@ 10 Hz
@ 100 Hz
@ 1000 Hz
@ 10 kHz
@ 200 kHz ~ 1 MHz
∆f(1h)/f0 < ± 0.1 ppm
@ +25°C
HBM as in IEC 610004-2
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1 and MIL-PRF55310, unless
otherwise stated
Ordering Code:
Model (Specification)
AXIOM50
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Frequency [MHz]
100.000
AXIOM50
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections:
Pin # Symbol
1
N.C.
2
N.C.
3
RF OUT
4
GND
5
Vs
Function
Not Connected
Not Connected
RF Output
Ground
Supply Voltage
Environmental conditions
Test
IEC
60068
Part
IEC
MIL PRF60679-1 55310D
Clause Clause
Test conditions
4.3
Enclosure styles as in IEC 60679-3 or
61837, if applicable
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Visual inspection,
dimensions
Solderability
Resistance to
soldering heat
Altitude
2-20
2-58
Shock*
2-27
4.6.8
3.6.40
Vibration,
sinusoidal*
2-6
4.6.7
3.6.38.1
3.6.38.2
Rapid change of
temperature
Dry heat
2-14
4.6.5
3.6.44
2-2
4.6.14
2-30
4.6.15
2-1
4.6.16
Climatic
1-7
sequence*
Damp heat, steady 2-3
state*
Endurance tests
- ageing
- extended aging
4.6.17
Damp heat,
cyclic*
Cold
4.6.3
4.6.18
4.7.1
4.7.2
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
4.2.2
4.8.1
3.6.52
3.6.48
4.8.35
3 000 m operational
12 000 m transport
Test Ea, 3 x per axes 100g, 6 ms half-sine
pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz,
10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b), 55°C/95%
r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st cycle),
4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
AXIOM50
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]