DAESAN SM4006

CURRENT 1.0 Ampere
VOLTAGE 50 to 1000 Volts
SM4001 THRU SM4007
Features
· The plastic package carries Underwrites Laboratory
Flammability Classification 94V-0
· For surface mounted applications
· Glass passivated junction
· High temperature soldering guaranteed: 250℃/10
seconds, at terminals
MELF (DO-41)
SOLDERABLE ENDS
0.024(0.60)
0.018(0.46)
Mechanical Data
0.105(2.70)
0.095(2.40)
0.205(5.20)
0.190(4.80)
· Case : JEDEC MELF(DO-41) molded plastic body
· Terminals : Lead solderable per MIL-STD-750,
method 2026
· Polarity : Color band denotes cathode end
· Mounting Position : Any
· Weight : 0.0041 ounce, 0.116 gram
Dimensions in inches and (millimeters)
Maximum Ratings And Electrical Characteristics
(Ratings at 25℃ ambient temperature unless otherwise specified, Single phase, half wave 60Hz, resistive or inductive
load. For capacitive load, derate by 20%)
Symbols
SM
4001
SM
4002
SM
4003
SM
4004
SM
4005
SM
4006
SM
4007
Units
Maximum recurrent peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum average forward rectified current
0.375"(9.5mm) lead length at TA=75℃
I(AV)
1.0
Amp
Peak forward surge current 8.3ms half sine
wave superimposed on rated load
(JEDEC method)
IFSM
30.0
Amps
Maximum instantaneous forward voltage
at 1.0A
VF
1.1
Volts
Maximum reverse
current at rated voltage
TA=25℃
TA=125℃
IR
5.0
50.0
μA
RθJA
RθJL
75.0
Typical junction capacitance (Note 1)
CJ
15.0
pF
Maximum DC blocking voltage temperature
TA
+150
℃
TJ
TSTG
-65 to +150
℃
Typical thermal resistance
(Note 2)
(Note 3)
Operating and storage temperature range
30.0
Notes:
(1) Measured at 1MHz and applied reverse voltage of 4.0V DC.
(2) Thermal resistance from junction to ambient, 0.24×0.24"(6.0×6.0mm) copper pads to each terminals
(3) Thermal resistance from junction to terminals, 0.24×0.24"(6.0×6.0mm) copper pads to each terminals
℃/W
RATINGS AND CHARACTERISTIC CURVES SM4001 THRU SM4007
FIG.1-FORWARD CURRENT DERATING CURVE
FIG.2-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
AVERAGE FORWARD CURRENT AMPERES
1.0
0.8
INSTANTANEOUS FORWARD CURRENT(AMPERES)
20
0.6
0.4
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
0.2
0
0
25
50
75
100
125
150
175
LEAD TEMPERATURE ( ℃)
10
1
TJ=25℃
PULSE WIDTH=300mS
0.1
1% DUTY CYCLE
0.01
FIG.3-MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
0.6
0.8
1.0
1.2
1.4
1.5
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
40
30
FIG.4-TYPICAL REVERSE CHARACTERISTICS
20
10
10
0
1
10
100
NUMBER OF CYCLES AT 60Hz
FIG.5-TYPICAL JUNCTION CAPACITANCE
INSTANTANEOUS REVERSE CURRENT (mA)
PEAK FORWARD SURGE
CURRENT (AMPERES)
50
TJ=100℃
1.0
0.1
TJ=25℃
JUNCTION CAPACITANCE(pF)
100
0.01
0
20
40
60
80
100
TJ=25℃
PERCENT OF RATED PEAK REVERSE VOLTAGE (%)
10
1
0.1
1
10
REVERSE VOLTAGE. VOLTS
100
120
140