EDI SL500

SL300 thru SL 1200
FAST RECOVERY, 100ns.HIGH VOLTAGE
40 ma, MINIATURE RECTIFIERS
1 INCH MINIMUM LEADS
SMALL SIZE MOLDED PACKAGE
PRV 3,000 TO 12,000 VOLTS
AVALANCHE CHARACTERISTICS
LOW LEAKAGE
EDI
Type
PRV
Volts
SL300
SL500
SL800
SL1000
SL1200
3,000
5,000
8,000
10,000
12,000
ELECTRICAL CHARACTERISTICS (at TA =25 o C Unless Otherwise Specified)
o
Average Rectified Forward Current @ 50 C, IO
40 mA
Max. Peak Surge Current, IFSM (8.3ms) (Fig.2)
3 Amp
100nanosec
Max. Reverse Recovery (Fig.4) t rr
26Volts
Max. ForwardVoltageDrop @25 m A, V F
o
1
Max. DC Reverse Current @ PRV and 25 C, IR
o
Max. DC Reverse Current @ PRV and100 C, I R
15
A
A
o
o
o
o
Ambient Operating Temperature Range, TA
-55 C to +150 C
Storage Temperature Range, TSTG
-55 C to +150 C
NOTES:
1.It is recommended that a proper heat sink be used on the terminals of this device between the body and
soldering point to prevent damage from excess heat.
2.If operated over 10,000v/inch in length, devices should be immersed in oil or re - encapsulated.
EDI reserves the right to change these specifications at any time without notice.
SL300 thru SL1200
FIG.1
FIG.2
OUTPUT CURRENT vs AMBIENT TEMPERATURE
NON- REPETITIVE SURGE CURRENT
0.1SEC
% MAXIMUM SURGE
% RATED FWD CURRENT
1.0SEC
100
100
75
50
25
75
50
25
0
0
0
25
50
75
100
125
1
150
2
3
O
AMBIENT TEMPERATURE ( C)
4
5 6 7 8 9 10
20
30
40 50 60
CYCLES(60 Hz)
FIG.3
MECHANICAL
LEAD-SOLDER DIPPED COPPER
MARKING:CATHODE BAND
AND DEVICE TYPE
1.0Min Both Ends
.021 Dia.
.125 Dia.
.400
FIG.4
REVERSE RECOVERY TEST METHOD
RECOVERY WAVE FORM
RECOVERY WA VE FORM
1000
Trr
NI
+
I F=2MA
D.U.T.
0.1
50
NI
I RR=1MA
PULSE
GENERATOR
I R=5MA
SCOPE
WAVE FORMS
CIRCUIT
ELECTRONIC DEVICES, INC. DESIGNERS AND MANUFACTURERS OF SOLID STATE DEVICES SINCE 1951.
21 GRAY OAKS AVENUE
* YONKERS. NEW YORK 10710 914-965-4400
Ee-mail:[email protected] * Wwebsite: http://www.edidiodes.com
* FAX 914-965-5531
* 1-800-678-0828