ETC CMX100D6

Series CMX
5-10 Amp • 0-60, 0-100 Vdc • DC Output SIP
• MOSFET Output
• Extra Low On-State
Resistance
DC output SPST-NO solid state relays
use MOSFET output for high switching
capabilities in a PC-mount air-cooled
package. Pinouts are compatible with
Series 6 and ODC type I/O modules.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NO.
CURRENT DERATING CURVES
INPUT SPECIFICATIONS ➀
7.0
6.0
LOAD CURRENT [AMPS]
CMX60D5➂ CMX60D10➂ CMX100D6➂
3.0-10.0 Vdc
Control Voltage Range
CMX100D6
5.0
4.0
CMX60D5
3.0
2.0
1.0
Nominal Input Impedance
300 Ohm
Typical Input Current @ 5 Vdc
15 mAdc
Must Turn On Voltage
3.0 Vdc
Must Turn Off Voltage
1.0 Vdc
0
20
40
60
80
OUTPUT SPECIFICATIONS ➀
LOAD CURRENT [AMPS]
AMBIENT TEMPERATURE [ºC]
12.0
Operating Voltage Range
0-60 Vdc
0-60 Vdc
0-100 Vdc
10.0
Load Current Range
0-5 Adc
0-10 Adc
0-6 Adc
Max. Surge Current, (10 msec)
60 Apk
100 Apk
100 Apk
8.0
CMX60D10
6.0
4.0
2.0
0
20
40
60
Max.Off-State Leakage @ Rated Voltage
100 µAdc
Max. On-State Resistance @ Rated Current (RDS-ON) .10 Ohm
.018 Ohm
.040 Ohm
0.18V
0.24V
Max. On-State Voltage Drop @ Rated Current
80
AMBIENT TEMPERATURE [ºC]
Max. Load Current vs. Temp.
Max.Turn-On Time
1.0 msec
Max. Turn-Off TIme
300 µsec
GENERAL SPECIFICATIONS
.300 (7.6)
Dielectric Strength
➁
Insulation Resistance (Min.) @ 500 Vdc
1.00
MAX.
(25.4)
➁
Max. Capacitance (Input/Output)
CONTROL
.300 TYP.
(7.6)
4
.200
(5.1)
3
.700
(17.8)
1.70
(43.1)
LOAD
2
Ambient Operating Temperature Range
1
1.100
(27.9)
.050
TYP.
(1.3)
Ambient Storage Temperature Range
.100
(2.5)
.040 (1.0) DIA.
(4 PLACES)
PIN
PIN
PIN
PIN
1:
2:
3:
4:
+DC LOAD
--DC LOAD
+DC CONTROL
--DC CONTROL
All dimensions are in inches (millimeters)
APPROVALS
UL E116950 (6A & 10A Models)
FastFax Document No. 109
SERIES CMX032698, PAGE 1 OF 1
0.5V
2500 Vrms
109 Ohm
15 pF
-30 to 80ºC
-30 to 125ºC
MECHANICAL SPECIFICATIONS
0.4 oz. (11 g)
Weight: (typical)
Thermally Conductive Epoxy
Encapsulation:
GENERAL NOTES
➀
➁
➂
©1998 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25ºC unless otherwise specified.
Dielectric and insulation resistance are
measured between input and output.
Inductive loads should be diode suppressed.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • e-mail: [email protected]