ETC TS6601HC

Tact Switch Series (6x6mm)
TS6601H
Dimensions
Part Number
Model No.
High (L)
Model No.
High (L)
TS6601H
4.3
TS6601HE
7.3
TS6601HA
5.0
TS6601HF
12.5
TS6601HB
7.0
TS6601HG
13.5
TS6601HC
8.0
TS6601HK
4.7
TS6601HD
9.5
Tact Switch Series (6x6mm)
9mm Metal Shaft Rotary Potentiometer (9mm 金屬軸旋轉電位器)
TACTING SWITCH SPECIFICATION
1. GENERAL
1.1 Scope
This specification covers the requirements for single key switches which have no
keytop(TACT SWITCHES:MECHANICAL CONTACT).
1.2 Operating Temperature Range
-20 to 70°C (normal humidity, normal press.)
1.3 Storage Temperature Range
-30 to 80°C (normal humidity, normal press.)
1.4 Test Conditions
Tests and measurements shall be made in the following standard conditions unless
otherwise specified:
Normal temperature (temperature 5 to 35°C)
Normal humidity (relative humidity 45 to 85%)
Normal pressure (pressure 860 to 1060 m bars)
In case any question arises from the judgement made, tests shall be conducted in the
following conditions:
Temperature
Relative humidity
Pressure
(20±2°C)
(65±5%)
(860 to 1060 m bars)
2. APPEARANCE, STYLE, AND DIMENSIONS
2.1 Appearance
There shall be no defects that affect the serviceability of the product.
2.2 Style and Dimensions
Shall conform to the assembly drawings.
3. TYPE OF ACTUATION
Tactile
feedback
4. CONTACT ARRANGEMENT
1 poles 1 throws
(Details of contact arrangement are given in the assembly drawings.)
5. MAXIMUM RATINGS
DC
12
V
50
Ma
PART NO: TS6601H
1/6
TACTING SWITCH SPECIFICATION
6. PERFORMANCE
6.1 Electrical
Item
Test Conditions
Requirements
6.1.1.
Contact
Resistance
Applying a static load twice the actuating force to
the center of the stem, measurements shall be made
with a 1 kHz small-current contact resistance meter.
6.1.2.
Insulation
Resistance
Measurements shall be made following application of
DC 250 V potential across terminals and across
terminals and frame for one minute.
6.1.3.
Dielectric with-
AC 500 V (50Hz or 60Hz) shall be applied across
terminals and across terminals and frame for one
There shall be no
minute.
breakdown.
standing
voltage
6.1.4.
Bounce
Lightly striking the center of the stem at a rate
encountered in normal use (3 to 4 operations per sec.),
bounce shall be tested at “ON” and “OFF”.
PART NO:
100
m ohm max.
100
M ohm min.
5
m sec max.
TS6601H
2/6
TACTING SWITCH SPECIFICATION
6.2 Mechanical
Item
6.2.1.
Actuating
Force
6.2.2.
Travel
Test Conditions
Requirements
Placing the switch such that the direction of switch
operation is vertical and then gradually increasing the
load applied to the center of the stem, the maximum
load required for the stem to come to a stop shall be
measured.
Placing the switch such that the direction of switch
operation is vertical and then applying a static load
twice the actuating force to the center of the stem, the
travel distance for the stem to come to a stop shall be
160
± 50
OR
gf
250
±
50
gf
0.3
±
0.15 m m
measured.
6.2.3.
Return
Force
The sample switch is installed such that the direction
of switch operation is vertical and, upon depression of
the stem in its center the whole travel distance, the
force of the stem to return to its free position shall be
measured.
6.2.4.
Stop
Strength
Placing the switch such that the direction of switch
operation is vertical, a static load of 3 kgf shall be
applied in the direction of stem operation for a period
of 60 seconds.
6.2.5
Stem
Strength
Placing the switch such that the direction of switch
operation is vertical, the maximum force to withstand
a pull applied opposite to the direction of stem
operation shall be measured.
50
g f min.
There shall be no sign
of damage
mechanically
and electrically.
PART NO:
3
kgf
TS6601H
3/6
TACTING SWITCH SPECIFICATION
6.3 Environmental
Item
Test Conditions
Requirements
6.3.1.
Resistance to
Low
Temperatures
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
6.3.2.
Heat
Resistance
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
(1)Temperature: -30±2°C
(2)
Time: 96 hours
(3)Water drops shall be removed.
(1)Temperature: 80±2°C
(2)
Time: 96 hours
6.3.3.
Moisture
Resistance
Following the test set forth below the sample shall be
left in normal temperature and humidity conditions
for one hour before measurements are made:
(1)
Temperature: 60±2°C
(2)Relative humidity: 90 to 95%
(3)
Time: 96 hours
(4)Water drops shall be removed.
6.3.4.
Temperature
Cycling
Following five cycles of the temperature cycling test
set forth below the sample shall be left in normal
temperature and humidity conditions for one hour
before measurements are made.
During this test, water drops shall be removed.
1 cycle
Item 6.1
Item 6.2.1
Item 6.2.2
Item 6.1
Item 6.2.1
Item 6.2.2
Contact resistance:
200 m ohm max.
Insulation resistance:
10
M ohm min.
Item 6.1.3
Item 6.1.4
Item 6.2.1
Item 6.2.2
Item 6.1
Item 6.2.1
Item 6.2.2
+60℃
-10℃
2H
1H
2H
1H
PART NO:
TS6601H
4/6
TACTING SWITCH SPECIFICATION
6.4 Endurance
Item
6.4.1.
Operating Life
Test Conditions
Requirements
Measurements shall be made following the test set
forth below:
(1)DC 5V 5mA resistive load
(2)Rate of operation: 2 to 3 operations per second
(3)Depression:
300 g f
(4)Cycles of operation:
10 x104 cycles
Contact resistance:
200 m ohm max.
Insulation resistance:
10 M ohm min.
Bounce: 10 m sec
max.
Actuating force:
+ 30 % or
- 30 % of initial
force Item 6.1.3
Item 6.2.2
6.4.2.
Vibration
Resistance
6.4.3.
Impact Shock
Resistance
Measurements shall be made following the test set
forth below:
Item 6.1
Item 6.2.1
(1)Range of oscillation: 10 to 55 Hz
(2)Amplitude, pk-to-pk:1.5 mm
(3)Cycle of sweep: 10 -55 -10 Hz in one minute,
approx.
(4)Mode of sweep: Logarithmically sweep or
uniform sweep
(5)Direction of oscillation:
Three mutually perpendicular directions,
including the direction of stem travel
(6)Duration of testing:
2 hours each, for a total of 6 hours
Item 6.2.2
Measurements shall be made following the test set
forth below:
(1)Acceleration:80g
(2)Cycles of test:3 cycles each in 6 directions, for a
total of 18 cycles
Item 6.1
Item 6.2.1
Item 6.2.2
PART NO:
TS6601H
5/6
TACTING SWITCH SPECIFICATION
7. Switch Handling Precautions
7.1 In case an automatic flow soldering apparatus is used for soldering, adhere to the following
conditions:
Item
Soldering condition
100℃ max
7.1.1. Preheat Temperature
7.1.2. Preheat Time
7.1.3. Flux Foaming
7.1.4. Soldering Temperature
7.1.5. Duration of Solder Immersion
7.1.6. Allowable Frequency of Soldering process
(Ambient temperature of printed circuit board on
its soldering side)
45 sec max.
To such an extent that fluxes will be kept flush with
the printed circuit board‘s top surface on which
components are mounted.
Preparatory flux must not be applied to that side of
printed circuit board on which components are
mounted and to the area where terminals located.
255℃ max.
5 sec. max.
2 times max.
7.2 Other precautions
7.2.1. Following the soldering process, do not try to clean the switch with a solvent or the like.
7.2.2. Safeguard the switch assembly against flux penetration from its topside.
7.2.3. Please have the products keep in close status and the storage time is 90 days guaranty after
delivering the goods at most.
PART NO:
TS6601H
6/6