LEM HX03-P_06

Current Transducer HX 03..50-P
IPN = 3 .. 50 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
3
5
10
15
20
25
50
VOUT
ROUT
RL
VC
IC
Vd
Ve
VW
Primary current,
measuring range
IPM (A)
±9
± 15
± 30
± 45
± 60
± 75
± 150
Primary conductor
diameter x turns
(mm)
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
Type
RoHS since
date code
HX 03-P
HX 05-P
HX 10-P
HX 15-P
HX 20-P
HX 25-P
HX 50-P
Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
Supply voltage (± 5 %)1)
Current consumption
Rms voltage for AC isolation test, 50Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
planned
45341
45340
45352
45319
45351
45288
±4
< 50
≥ 10
± 15
< ± 15
>3
≥1
≥6
V
Ω
kΩ
V
mA
kV
kV
kV
ε
L
VOE
VOH
TCVOE
TCVOUT
tr
BW
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Temperature coefficient of VOE
Temperature coefficient of VOUT (% of reading)
Response time to 90% of IPN step
Frequency bandwidth (- 3 dB) 2)
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
•
•
•
•
•
•
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range (3 x IPN)
Power supply from ±12V to ±15V
Insulated plastic case recognized
according to UL94-V0.
Advantages
• Low insertion losses
• Easy to mount with automatic
handling system
< ± 1 % of IPN
< ± 1 % of IPN
< ± 40
mV
< ± 15
< ± 1.5
± 0.1
≤3
50
mV
mV/K
%/K
µs
kHz
General data
TA
TS
m
dCp
• Galvanic isolation between primary
• Small size and space saving
• Only one design for wide current
Accuracy-Dynamic performance data
X
Features
ratings range
• High immunity to external
interference.
Applications
• Switched Mode Power Supplies
(SMPS)
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
≥ 5.5
mm
I
EN50178: 1997
• Electrical appliances
• Battery supplied applications
• DC motor drives
Application domain
• Industrial
Notes : 1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2)
Small signal only to avoid excessive heating of the magnetic cores
Page 1/2
061026/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HX 03..50-P (in mm. 1 mm = 0.0394 inch)
03..25-P
HXHX03...25-P
50-P
HXHX50-P
19 Max.
19 Max.
20 Max.
3
3.5
3.5
3.5
10.85
3
1 ..... -15 V
2 ..... 0 V
3 ..... +15 V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
0.5
0.5
20 Max.
Terminal Pin Identification
3
8.8
5.4
Primary conductor diameter
d
3-P=2.54
5
3 +V
2 0
1 -V or 0
03-P
05-P
10-P
15-P
d
0.6
0.8
1.1
1.4
HX
20-P
25-P
50-P
d
1.6
1.6
12 x 6.3
1.3
4.5
5
5
3.5
6
3 +V
2 0
1 -V or 0
6
4 OUT
15.4 Max.
6
15.4 Max.
3.5 3-P=2.54
4 OUT
HX
1.2
3
10.85
3
8.8
5.4
Secondary pins dimension
0.5 x 0.25
Top view
HX 05-P
41123
Lot No.
Terminal Pin Identification
1.....-15V
2.....0V
3.....+15V
4.....Output
Primary conductor diameter
/ dimension
HX 03-P 05-P 10-P 15-P 20-P 25-P 50-P
d
5.....Primary input Current(+)
6.....Primary input Current(-)
0.6
0.8
1.1
1.4
Safety
1.6
1.6
1.2x6.3
Secondary pins dimension
0.5x0.25
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/2
061026/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com