IPN = 15 At Current Transducer LTS 15-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 16058 Electrical data IPN IPM ÎPDC VOUT NS RL R IM TCR IM VC IC Features Primary nominal current rms Primary current, measuring range Overload capability (direct current) Analog output voltage @ IP IP = 0 Number of secondary turns (± 0.1 %) Load resistance Internal measuring resistance (± 0.5 %) Temperature coefficient of R IM Supply voltage (± 5 %) Current consumption @ VC = 5 V Typ 15 At 0 .. ± 48 At 250 At 2.5 ± (0.625·IP/IPN) V 2.5 1) V 2000 ≥2 kΩ 83.33 Ω < 50 ppm/K 5 V 28+ IS2) +(VOUT /RL) mA Accuracy - Dynamic performance data X ε Accuracy @ IPN , TA = 25°C Accuracy with R IM @ IPN , TA = 25°C Linearity error L TCVOUT Temperature coefficient of VOUT @ IP = 0 - 10°C .. + 85°C - 40°C .. - 10°C TCG Temperature coefficient of G - 40°C .. + 85°C VOM Magnetic offset voltage @ IP = 0, after an overload of 3 x IPN 5 x IPN 10 x IPN t ra tr di/dt BW Reaction time @ 10 % of IPN Response time to 90 % of IPN step di/dt accurately followed Frequency bandwidth (0 .. - 0.5 dB) (- 0.5 .. 1 dB) ± 0.2 ± 0.7 < 0.1 % % % Typ 65 Maxi 120 ppm/K 170 ppm/K 50 3)ppm/K ± 0.5 ± 2.0 ± 2.0 < 100 < 400 > 35 DC .. 100 DC .. 200 mV mV mV ns ns A/µ s kHz kHz Notes: Ambient operating temperature Ambient storage temperature Mass Standards 1) 2) 3) • • • • • range current transducer using the Hall effect Unipolar voltage supply Compact design for PCB mounting Isolated plastic case recognized according to UL 94-V0 Incorporated measuring resistance Extended measuring range. Advantages • • • • • • • Excellent accuracy Very good linearity Very low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability. Applications • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Switched Mode Power Supplies (SMPS) • Power supplies for welding General data TA TS m • Closed loop (compensated) multi- Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525 IS= IP/N S Only due to TCR IM. - 40 .. + 85 °C - 40 .. + 100 °C 10 g EN 50178: 1997 IEC 60950-1: 2001 applications. Application domain • Industrial. Copyright protected. Page 1/3 061102/17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Current Transducer LTS 15-NP Isolation characteristics Vd Vw Rms voltage for AC isolation test, 50/60 Hz, 1 min Impulse withstand voltage 1.2/50 µs 3 >8 kV kV Ve Rms voltage for partial discharge extinction @ 10pC Mini >1.5 kV dCp dCl CTI Creepage distance 4) Clearance distance 5) Comparative Tracking Index (Group III a) Mini 15.5 6.35 175 mm mm Application examples According to EN 50178 and IEC 61010-1 standards and following conditions: • Over voltage category OV 3 • Pollution degree PD2 • Non-uniform field EN 50178 IEC 61010-1 Rated isolation voltage Nominal voltage Single isolation 600 V 600 V Reinforced isolation 300 V 300 V dCp, dCI, V W Notes: 4) 5) On housing On PCB with soldering pattern UTEC93-703. Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 061102/17 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Dimensions LTS 15-NP (in mm. 1 mm = 0.0394 inch) Operation principle Bottom view Front view Back view Number of primary turns 1 Right view Primary nominal current rms IPN [ A ] ± 15 Nominal output voltage VOUT [ V ] 2.5 ± 0.625 Primary resistance R P [ mΩ ] 0.18 Primary insertion inductance L P [ µH ] Recommended connections ± 7.5 2.5 ± 0.625 0.81 ±5 2.5 ± 0.625 1.62 • General tolerance • Fastening & connection of primary Recommended PCB hole • Fastening & connection of secondary Recommended PCB hole • Additional primary through-hole OUT 1 6 2 5 3 4 OUT 1 6 2 5 3 4 OUT 1 2 3 0.12 IN Mechanical characteristics 4 0.05 IN 3 5 0.013 IN 2 6 Output Voltage - Primary Current VOUT [ V ] ± 0.2 mm 6 pins 0.8 x 0.8 mm 1.3 mm 3 pins 0.5 x 0.35 mm 0.8 mm ∅ 3.2 mm 5 4.5 3.125 2.5 1.875 Remarks 0.5 • VOUT is positive when IP flows from terminals 1, 2, 3 to terminals 6, 5, 4. • Temperature of the primary jumper should not exceed 100°C. 061102/17 - IP - IPN 0 IPN LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. IP IP [ At ] Page 3/3