Current Transducer LTS 6-NP IPN = 6 At For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 16065 Electrical data IPN IPM ÎPDC VOUT NS RL R IM TCR IM VC IC Primary nominal current rms Primary current, measuring range Overload capability (direct current) Output voltage (Analog) @ IP IP = 0 Number of secondary turns (± 0.1 %) Load resistance Internal measuring resistance (± 0.5 %) Temperature coefficient of R IM Supply voltage (± 5 %) Current consumption @ VC = 5 V Typ 6 At 0 .. ± 19.2 At 250 At 2.5 ± (0.625·IP/IPN) V 2.5 1) V 2000 ≥2 kΩ 208.33 Ω < 50 ppm/K 5 V 28+ IS2) +(VOUT /RL) mA ε Accuracy @ IPN , TA = 25°C Accuracy with R IM @ IPN , TA = 25°C Linearity error L TCVOUT Temperature coefficient of VOUT @ IP = 0 - 10°C .. + 85°C - 40°C .. - 10°C TCG Temperature coefficient of G - 40°C .. + 85°C VOM Residual voltage @ IP = 0, after an overload of 3 x IPN 5 x IPN 10 x IPN t ra tr di/dt BW Reaction time @ 10 % of IPN Response time to 90 % of IPN step di/dt accurately followed Frequency bandwidth (0 .. - 0.5 dB) (- 0.5 .. 1 dB) ± 0.2 ± 0.7 < 0.1 Typ 80 % % % Maxi 200 ppm/K 250 ppm/K 50 3) ppm/K ± 0.5 mV ± 2.0 mV ± 2.0 mV < 100 < 400 > 15 DC .. 100 DC .. 200 ns ns A/µ s kHz kHz General data TA TS m Notes: Ambient operating temperature Ambient storage temperature Insulating material group Mass Standards 4) 1) 2) 3) 4) • Closed loop (compensated) multi• • • • • range current transducer using the Hall effect Unipolar voltage supply Compact design for PCB mounting Isolated plastic case recognized according to UL 94-V0 Incorporated measuring resistance Extended measuring range. Advantages Accuracy - Dynamic performance data X Features - 40 .. + 85 - 40 .. + 100 III a 10 °C °C • • • • • • • Excellent accuracy Very good linearity Very low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability. Applications • AC variable speed drives and servo • • • • • motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. g EN 50178: 1997 IEC 60950-1 : 2001 Absolute value @ TA = 25°C, 2.475 < VOUT < 2.525 IS= IP/N S Only due to TCR IM Specification according to IEC 61000-4-3 are not guaranteed between 95 and 110 MHz (value higher by 5% than the specification). Application domain • Industrial. Copyright protected. Page 1/3 061213/16 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Current Transducer LTS 6-NP Isolation characteristics Vd VW Rms voltage for AC isolation test, 50 Hz, 1 min Impulse withstand voltage 1.2/50 µs 3 >8 kV kV Ve Rms voltage for partial discharge extinction @ 10pC Mini > 1.5 kV dCp dCl CTI Creepage distance 5) Clearance distance 6) Comparative Tracking Index (Group III a) Mini 15.5 6.35 175 mm mm Application examples According to EN 50178 and IEC 61010-1 standards and following conditions: • Over voltage category OV 3 • Pollution degree PD2 • Non-uniform field EN 50178 IEC 61010-1 Rated isolation voltage Nominal voltage Single isolation 600 V 600 V Reinforced isolation 300 V 300 V dCp, dCI, V W Notes: 5) 6) On housing On PCB with soldering pattern UTEC93-703. Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 061213/16 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com Dimensions LTS 6-NP (in mm. 1 mm = 0.0394 inch) Operation principle Bottom view Front view Back view Number of primary turns 1 Primary nominal current rms IPN [ A ] Right view Nominal output voltage VOUT [ V ] Primary resistance R P [ mΩ ] Primary insertion inductance L P [ µH ] 2.5 ± 0.625 0.18 0.013 ±6 Recommended connections IN 2 ±3 2.5 ± 0.625 0.81 ±2 2.5 ± 0.625 1.62 4 OUT 1 6 2 5 3 4 OUT 1 6 2 5 3 4 OUT 1 2 3 0.12 IN Mechanical characteristics 5 0.05 IN 3 6 Output Voltage - Primary Current • General tolerance • Fastening & connection of primary VOUT [ V ] ± 0.2 mm 6 pins 0.8 x 0.8 mm Recommended PCB hole 1.3 mm • Fastening & connection of secondary 3 pins 0.5 x 0.35 mm Recommended PCB hole 0.8 mm • Additional primary through-hole ∅ 3.2 mm 5 4.5 3.125 2.5 1.875 Remarks 0.5 • VOUT is positive when IP flows from terminals 1, 2, 3 to terminals 6, 5, 4. • Temperature of the primary jumper should not exceed 100°C. - IPmaxi - IPN 0 IPN IPmaxi IP [ At ] Page 3/3 061213/16 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. w w w .lem.com