Current Transducer HX 05 .. 15-NP IPN = 5 .. 15 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal current rms IPN (A) Primary current, measuring range IPM (A) Serial Parallel Series Parallel ±5 ± 10 ± 15 ± 10 ± 20 ± 30 ± 15 ± 30 ± 45 ± 30 ± 60 ± 90 VOUT ROUT RL VC IC Vd Ve VW Primary conductor diameter x turns (mm) 0.8d x (6T+6T) 1.0d x (3T+3T) 1.2d x (2T+2T) Type RoHS since date code Features • Galvanic isolation between primary HX 05-NP HX 10-NP HX 15-NP Output voltage (Analog) @ ± IPN, RL = 10 kΩ, TA = 25°C Output internal resistance Load resistance Supply voltage (± 5 %)1) Current consumption Rms voltage for AC isolation test, 50 Hz, 1 min Primary to secondary Primary 1 to primary 2 Partial discharge extinction voltage rms @ 10 pC Impulse withstand voltage, 1.2/50 µs planned planned 46047 ±4 < 50 ≥ 10 ± 15 < ± 15 >3 >1 ≥1 ≥6 V Ω kΩ V mA kV kV kV kV • • • • • • • and secondary circuit Hall effect measuring principle Isolation voltage 3000V 2 isolated primary windings Low power consumption Extended measuring range(3 x IPN) Power supply from ±12V to ±15V Insulated plastic case recognized according to UL94-V0. Advantages • Low insertion losses • Easy to mount with automatic handling system • Only one design for wide current Accuracy-Dynamic performance data ratings range X ε L VOE VOH TCVOE TCVOUT tr BW Accuracy @ IPN, TA = 25°C (excluding offset) Linearity error (0 .. ± IPN) Electrical offset voltage @ TA = 25°C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN Temperature coefficient of VOE Temperature coefficient of VOE (% of reading) Response time to 90% of IPN step Frequency bandwidth (- 3 dB) 2) < ± 1 % of IPN < ± 1 % of IPN < ± 40 mV < ± 15 < ± 1.5 ± 0.1 ≤3 50 mV mV/K %/K µs kHz General data TA TS m dCp Ambient operating temperature Ambient storage temperature Mass Creepage distance Isolation material group Standards • Small size and space saving • High immunity to external interference. Applications • Switched Mode Power Supplies (SMPS) • AC variable speed drives • Uninterruptible Power Supplies (UPS) - 25 .. + 85 °C - 25 .. + 85 °C 8 g ≥ 5.5 mm I EN50178: 1997 • Electrical appliances • Battery supplied applications • DC motor drives Application domain • Industrial Notes :1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN 2) Small signal only to avoid excessive heating of the magnetic core Page 1/2 061026/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HX 05..15-NP (in mm. 1 mm = 0.0394 inch) 15.4 Max. 0.5 20 Max. 19 Max. d 4 3.5+/-0.5 10.85 OUT 3 +V 0 2 8 7 5 HX 05-NP 41123 3.5 1 -V or 0 Top view 6 6 4 4.5 P=2.54 6 3 10.85 4 Lot No. Terminal Pin Identification 1...... -15V 2...... 0V 3...... +15V 4...... Output 5...... Primary 1 input Current(-) 7...... Primary 1 input Current(+) 6...... Primary 2 input Current(-) 8...... Primary 2 input Current(+) Primary conductor diameter HX HX 05-NP 05-NP10-NP 10-NP dd 0.8 0.8 1.0 1.0 15-NP 1.2 Secondary pins dimension 0.5 x 0.25 Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/2 061026/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com