LEM LV100_03

Voltage Transducer LV 100
IPN = 10 mA
VPN = 100 .. 2500 V
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 15 V
ISN
KN
VC
IC
Vd
@ ± 10 mA
@ ± 20 mA
10
mA
0 .. ± 20
mA
RM min
RM max
max
max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test 1), 50 Hz, 1 mn
0
0
150
50
50
10000 : 2000
± 15
10 + IS
6
Ω
Ω
Features
• Closed loop (compensated) voltage
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0.
mA
V
mA
kV
Principle of use
• For voltage measurements, a current
proportional to the measured voltage
must be passed through an external
resistor R 1 which is selected by the
user and installed in series with the
primary circuit of the transducer.
Accuracy - Dynamic performance data
XG
ε
Overall Accuracy @ IPN , TA = 25°C
Linearity
L
± 0.7
< 0.1
Typ
%
%
Max
± 0.2
± 0.3
Advantages
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
0°C .. + 70°C
± 0.2
mA
mA
tr
Response time 2) @ 90 % of VPN
20 .. 100
µs
0 .. + 70
- 25 .. + 85
1900
60
460
EN 50178
°C
°C
Ω
Ω
g
General data
TA
TS
RP
RS
m
Ambient operating temperature
Ambient storage temperature
Primary coil resistance @ TA = 70°C
Secondary coil resistance @ TA = 70°C
Mass
Standards
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
• Low disturbance in common mode.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications.
Notes :
1)
2)
Between primary and secondary
R 1 = 100 kΩ (L/R constant, produced by the resistance and inductance
of the primary circuit).
030131/6
LEM Components
w w w .lem.com
Dimensions LV 100
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
• General tolerance
• Transducer fastening
Fastening torque max
• Connection of primary
Fastening torque max
• Connection of secondary
Remarks
± 0.3 mm
2 holes ∅ 6.5 mm
M6 steel screws
5 Nm or 3.69 Lb - Ft.
M5 screw terminals
2.2 Nm or 1.62 Lb - Ft.
Faston 6.3 x 0.8 mm
• IS is positive when VP is applied on terminal +HT.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Instructions for use of the voltage transducer model LV 100
Primary resistor R 1 : the transducer’s optimum accuracy is obtained at the nominal primary current. As far as possible, R 1 should be
calculated so that the nominal voltage to be measured corresponds to a primary current of 10 mA.
Example: Voltage to be measured VPN = 1000 V
a) R 1 = 100 kΩ/40 W, IP = 10 mA
b) R 1 = 400 kΩ/ 5 W, IP = 2.5 mA
Accuracy = ± 0.7 % of VPN (@ TA = +25°C)
Accuracy = ± 2.5 % of VPN (@ TA = +25°C)
Operating range (recommended) : taking into account the resistance of the primary windings (which must remain low compared to R 1, in order
to keep thermal deviation as low as possible) and the isolation, this transducer is suitable for measuring nominal voltages from 100 to 2500 V.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.