MIW2000 Series 3-4W, Ultra-Wide Input Range DIP, Single & Dual Output DC/DC Converters Key Features y y y y y y y y y y Efficiency up to 85% 1500VDC Isolation MTBF > 1,000,000 Hours 4:1 Wide Input Range UL1950 Safety Approval Complies with EN55022 Class A Temperature Performance -40] to +71] Industry Standard Pinout UL 94V-0 Package Material Internal SMD Construction Minmax's MIW2000-Series power modules operate over input voltage ranges of 9-36VDC and 18-75VDC which provide precisely $ regulated output voltages of 3.3V, 5V, 12V, 15V, {5V, {12V and {15VDC. The -40] to +71] operating temperature range makes it ideal Low Cost for data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot 1500 VDC systems. The modules have a maximum power rating of 4W and a typical EMI 4:1 EN55022 Wide Range full-load efficiency of 85%, continuous short circuit, 50mA output ripple, EN55022 Class A conducted noise compliance minimize I/O Isolation design-in time, cost and eliminate the need for external filtering. Block Diagram Single Output +Vin Dual Output +Vo LC Filter +Vin +Vo LC Filter Com. -Vo -Vin 1 PFM Isolation Ref.Amp -Vo -Vin MINMAX PFM Isolation Ref.Amp REV:0 2005/04 MIW2000 Series Model Selection Guide Model Number Input Voltage Output Voltage VDC VDC 3.3 Max. mA 900 Min. mA 90 @Max. Load mA (Typ.) 161 MIW2022 5 660 66 170 MIW2023 12 333 33 201 15 267 27 201 {5 {300 {30 156 80 MIW2026 {12 {167 {17 201 83 MIW2027 {15 {133 {13 201 83 MIW2031 3.3 900 90 79 78 MIW2032 5 660 66 84 82 MIW2033 12 333 33 98 85 MIW2021 24 ( 9 ~ 36 ) MIW2024 MIW2025 MIW2034 48 ( 18 ~ 75 ) Output Current Input Current @No Load mA (Typ.) Reflected Ripple Current mA (Typ.) Efficiency @Max. Load % (Typ.) 77 81 83 20 15 267 27 98 {300 {30 76 82 MIW2036 {12 {167 {17 98 85 MIW2037 {15 {133 {13 98 85 85 Notes : Absolute Maximum Ratings Parameter Input Surge Voltage ( 1000 mS ) 5 83 {5 MIW2035 10 5 Min. Max. Unit 24VDC Input Models -0.7 50 VDC VDC 48VDC Input Models -0.7 100 Lead Temperature (1.5mm from case for 10 Sec.) --- 260 ] Internal Power Dissipation --- 2,500 mW Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings. 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. Environmental Specifications Parameter 6. All DC/DC converters should be externally fused at the front end for protection. Conditions Min. Max. Unit Operating Temperature Ambient -40 +71 ] Operating Temperature Case -40 +90 ] 7. Other input and output voltage may be available, please contact factory. Storage Temperature -40 +125 ] Humidity --- 95 % 8. Specifications subject to change without notice. Cooling Conducted EMI REV:0 2005/04 Free-Air Convection EN55022 Class A MINMAX 2 MIW2000 Series Input Specifications Parameter Start Voltage Model Under Voltage Shutdown Min. Max. 24V Input Models 4.5 6 8.5 48V Input Models 8.5 12 17 24V Input Models --- --- 8 48V Input Models Reverse Polarity Input Current Short Circuit Input Power Typ. All Models Unit VDC --- --- 16 --- --- 1 A --- --- 2000 mW Input Filter Pi Filter Output Specifications Parameter Conditions Output Voltage Accuracy Min. Typ. Max. Unit % --- {0.5 {1.0 Dual Output, Balanced Loads --- {0.5 {2.0 % Line Regulation Vin=Min. to Max. --- {0.2 {0.5 % Load Regulation Io=10% to 100% --- {0.3 {1.0 % --- 50 75 mV P-P Output Voltage Balance Ripple & Noise (20MHz) --- --- 100 mV P-P Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Line, Load & Temp. --- --- 15 mV rms Over Power Protection 120 --- --- % Transient Recovery Time --- 150 500 uS 25% Load Step Change Transient Response Deviation Temperature Coefficient Output Short Circuit --- {2 --- % --- {0.01 {0.02 %/] Continuous General Specifications Parameter Isolation Voltage Rated Conditions Min. Typ. Max. Unit 60 Seconds 1500 --- --- VDC Flash Tested for 1 Second 1650 --- --- VDC Isolation Resistance 500VDC 1000 --- --- M[ Isolation Capacitance 100KHz,1V --- 380 500 pF --- 350 --- KHz 1000 --- --- K Hours Isolation Voltage Test Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Capacitive Load Models by Vout 3.3V 5V 12V 15V {5V # {12V # {15V # Unit Maximum Capacitive Load 3000 3000 3000 3000 680 680 680 uF # For each output 3 MINMAX REV:0 2005/04 MIW2000 Series Input Fuse Selection Guide 24V Input Models 48V Input Models 1000mA Slow - Blow Type 500mA Slow - Blow Type Input Voltage Transient Rating 150 140 130 120 48VDC Input Models 110 Vin ( VDC ) 100 90 80 24VDC Input Models 70 60 50 40 30 20 10 0 10uS REV:0 2005/04 100uS 1mS MINMAX 10mS 100mS 4 100 100 90 90 Efficiency (%) Efficiency (%) MIW2000 Series 80 70 60 80 70 60 50 Low Nom 50 High Low Nom Input Voltage (V) Efficiency vs Input Voltage ( Dual Output ) 90 90 80 80 70 70 Efficiency (%) Efficiency (%) Efficiency vs Input Voltage ( Single Output ) 60 50 60 50 40 40 30 30 20 10 20 40 High Input Voltage (V) 60 80 100 20 Load Current (%) 10 20 40 60 80 100 Load Current (%) Efficiency vs Output Load ( Single Output ) Efficiency vs Output Load ( Dual Output ) 100 100LFM 400LFM Natural convection 200LFM Output Power (%) 80 60 40 20 0 〜 -40 50 60 70 80 Ambient Temperature 90 100 110 ] Derating Curve 5 MINMAX REV:0 2005/04 MIW2000 Series Test Configurations Overcurrent Protection Input Reflected-Ripple Current Test Setup To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz. To Oscilloscope + + Battery +Vin Lin Cin -Vin The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. +Out DC / DC Converter Current Probe Load -Out Peak-to-Peak Output Noise Measurement Test Use a Cout 0.47uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out +Vin Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 4.7uF for the 24V input devices and a 2.2uF for the 48V devices. + DC Power Source Copper Strip +Vin + Cout Dual Output DC / DC Converter Com. -Vin -Out Load Cin -Vin -Out Resistive Scope Load -Out +Out +Out DC / DC Converter - Single Output DC / DC Converter -Vin Input Source Impedance Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 3.3uF capacitors at the output. Copper Strip Cout Scope Cout Scope Resistive Load + +Vin DC Power Source Design & Feature Considerations +Out Single Output DC / DC Converter Cout - -Vin -Out + +Vin +Out Load Maximum Capacitive Load The MIW2000 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 680uF maximum capacitive load for dual outputs and 3000uF capacitive load for single outputs. The maximum capacitance can be found in the data sheet. REV:0 2005/04 Dual Output DC / DC Com. Converter DC Power Source MINMAX - -Vin -Out Cout Load 6 MIW2000 Series Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 90°C. The derating curves are determined from measurements obtained in an experimental apparatus. Position of air velocity probe and thermocouple 15mm / 0.6in 7 50mm / 2in Air Flow DUT MINMAX REV:0 2005/04 MIW2000 Series Mechanical Dimensions Connecting Pin Patterns Top View ( 2.54 mm / 0.1 inch grids ) Single Output 10.2 [0.40] Side 4.5 [0.18] 2 3 9 11 16 14 Bottom 23 22 Tolerance Pin Millimeters Inches X.X{0.25 X.XX{0.01 X.XX{0.13 {0.05 X.XXX{0.005 {0.002 Dual Output 20.3 [0.80] 2.54 [0.100] 2.5 [0.10] 0.50 [0.020] 15.22 [0.600] 4.1 [0.16] 31.8 [1.25] Pin Connections Physical Characteristics Pin Single Output Dual Output 2 -Vin -Vin 3 -Vin -Vin 9 No Pin Common 11 NC -Vout 14 +Vout +Vout 16 -Vout Common 22 +Vin +Vin 23 +Vin +Vin 31.8*20.3*10.2 mm Case Size : Case Material : Metal With Non-Conductive Baseplate Weight : 16.2g Flammability : UL94V-0 1.25*0.80*0.40 inches NC: No Connection The MIW2000 converter is encapsulated in a low thermal resistance molding compound that has excellent resistance/electrical characteristics over a wide temperature range or in high humidity environments. The encapsulant and unit case are both rated to UL 94V-0 flammability specifications. Leads are tin plated for improved solderability. REV:0 2005/04 MINMAX 8