NICHIA Product Guide( UTZ-SC0056_1 ) Aquamarine Laser Diode NDHA210APAE1 Engineering Sample Features Outline Dimension • Wavelength: 473nm • Optical Output Power: 20mW • Single Transverse Mode Unit (mm) (Tc=25°C) 0.25±0.03 1.0±0.1 Z+ Φ 4.2±0.2 Φ 3.55±0.1 Initial Electrical/Optical Characteristics Emitting Point Reference Plane Condition Symbol Min Typ. Max Unit Optical Output Power CW Po - - 20 mW Peak Wavelength Po=20mW λp 468 473 478 nm Threshold Current CW Ith 20 50 80 mA Operating Current Po=20mW Iop 50 100 150 mA Slope Efficiency CW η 0.2 0.45 0.8 W/A Operating Voltage Po=20mW Vop 4.0 5.5 7.0 V θ// 5 9 13 deg. θ⊥ 17 23 29 deg. ∆θ// - - ±2.5 deg. ∆θ⊥ - - ±5.0 deg. FWHM Beam Divergence Emission Point Accuracy Po=20mW 3 X+ 1 2 Φ 2.0±0.2 Y+ ( ) are reference figures Angle Po=20mW Position - ∆X, Y, Z - - ±80 µm Po=20mW Im 0.1 0.35 0.8 mA Monitor Current* 3×Φ 0.45±0.1 (Tc=25°C) Item Glass Thickness mW V °C °C 1.3±0.08 Po Vr (LD) Tstg Tc (0.4) 0.4±0.1 Optical Output Power LD Reverse Voltage Storage Temperature Operating Case Temperature Emitting Point Unit 1.2±0.1 2.3±0.2 Symbol (90° ) 6.5±1.0 Item Absolute Maximum Ratings 25 5 -35 ~ 70 0 ~ 60 0 + .03 0 - ( 1.6 ) Φ Absolute Maximum Ratings Φ 5.6 Pin Connection 2 1 PD LD 1. LD Anode 2. PD Anode 3. Common 3 This internal photodiode are solely Nichia's internal evaluation purpose only, and Nichia gives no warranty to Monitor Current. * Monitor Current is short time power reference purpose only. Not guaranteed for accuracy. All figures in this specification are measured by Nichia's method and may contain measurement deviations. This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed. The above specifications are for reference purpose only and subjected to change without prior notice. NICHIA CORPORATION http://www.nichia.co.jp HEAD OFFICE P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN PHONE: +81-884-22-2311 FAX: +81-884-21-0148 CONTACT TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV. 13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU, TOKYO 108-0014, JAPAN PHONE: +81-3-3456-3108 FAX: +81-3-5440-7330 -1- NICHIA Product Guide( UTZ-SC0056_1 ) Typical Characteristics Forward Voltage vs. Forward Current Optical Output Power vs. Forward Current 6 Tc=20℃ Tc=40℃ Tc=60℃ 15 5 Forward Voltage [V] Optical Output Power [mW] 20 10 5 4 3 2 Tc=20℃ Tc=40℃ 1 Tc=60℃ 0 0 0 20 40 60 80 0 100 20 60 80 100 Forward Current [mA] Forward Current [mA] Peak Wavelength vs. Case Temperature Threshold Current vs. Case Temperature 476 80 ●:Type1 ▲:Type2 75 Peak Wavelength [nm] Threshold Current [mA] 40 70 65 60 55 50 474 472 470 45 40 468 15 20 25 30 35 40 45 50 55 60 65 15 20 25 Case Temperature [℃] 60 65 Relative Optical Intensity Relative Optical Intensity 50 55 Spectrum θ// θ⊥ -20 40 45 Case Temperature [℃] Far Field Pattern -40 30 35 0 20 468 40 470 472 474 Wavelength [nm] Angle [°] -2- 476 478 NICHIA Product Guide( UTZ-SC0056_1 ) Cautions (1) Safety of Laser light Laser beam are extremely dangerous to human eyes. Never look at laser beam directly and/or through optical lens. When handling the LDs, wear appropriate safety glasses to prevent laser light, even any reflections from entering to the eye. Focused laser beam through optical instruments will increase the chance of eye hazard. Nichia LDs are classified in Class 3B of IEC60825-1 and 21 CFR Part 1040.10 Safety Standards. It is absolutely necessary to take overall safety measures against User's modules, equipment and systems into which Nichia LDs are incorporated and/or integrated. (2) Operating method The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current. Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering and/or overshooting in the Circuit. (3) Static Electricity Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist strap or anti-electrostatic glove when handling the Product. (4) Absolute Maximum Rating Active layer of LDs shall have high current density and generate high electric field during its operation. In order to prevent excessive damage, the LD must be operated strictly below Absolute Max Rating. (5) Others Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance for information on the applications in which exceptional quality and reliability are required, particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices). The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems. Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or design of the LD. The appearance and specifications of the product may be modified for improvement without notice. The formal specifications must be exchanged and signed by both parties before large volume purchase begins. No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted. -3-