NICHIA NDHA210APAE1

NICHIA
Product Guide( UTZ-SC0056_1 )
Aquamarine Laser Diode
NDHA210APAE1
Engineering Sample
Features
Outline Dimension
• Wavelength: 473nm
• Optical Output Power: 20mW
• Single Transverse Mode
Unit (mm)
(Tc=25°C)
0.25±0.03
1.0±0.1
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Initial Electrical/Optical Characteristics
Emitting Point
Reference Plane
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
CW
Po
-
-
20
mW
Peak Wavelength
Po=20mW
λp
468
473
478
nm
Threshold Current
CW
Ith
20
50
80
mA
Operating Current
Po=20mW
Iop
50
100
150
mA
Slope Efficiency
CW
η
0.2
0.45
0.8
W/A
Operating Voltage
Po=20mW
Vop
4.0
5.5
7.0
V
θ//
5
9
13
deg.
θ⊥
17
23
29
deg.
∆θ//
-
-
±2.5
deg.
∆θ⊥
-
-
±5.0
deg.
FWHM Beam
Divergence
Emission
Point
Accuracy
Po=20mW
3
X+
1
2
Φ 2.0±0.2
Y+
( ) are reference figures
Angle
Po=20mW
Position
-
∆X, Y, Z
-
-
±80
µm
Po=20mW
Im
0.1
0.35
0.8
mA
Monitor Current*
3×Φ 0.45±0.1
(Tc=25°C)
Item
Glass Thickness
mW
V
°C
°C
1.3±0.08
Po
Vr (LD)
Tstg
Tc
(0.4)
0.4±0.1
Optical Output Power
LD Reverse Voltage
Storage Temperature
Operating Case Temperature
Emitting Point
Unit
1.2±0.1
2.3±0.2
Symbol
(90°
)
6.5±1.0
Item
Absolute Maximum
Ratings
25
5
-35 ~ 70
0 ~ 60
0
+ .03
0
-
(
1.6
)
Φ
Absolute Maximum Ratings
Φ
5.6
Pin Connection
2
1
PD
LD
1. LD Anode
2. PD Anode
3. Common
3
This internal photodiode are solely
Nichia's internal evaluation purpose
only, and Nichia gives no warranty to
Monitor Current.
* Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
NICHIA CORPORATION
http://www.nichia.co.jp
HEAD OFFICE
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV.
13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU,
TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
NICHIA
Product Guide( UTZ-SC0056_1 )
Typical Characteristics
Forward Voltage vs. Forward Current
Optical Output Power vs. Forward Current
6
Tc=20℃
Tc=40℃
Tc=60℃
15
5
Forward Voltage [V]
Optical Output Power [mW]
20
10
5
4
3
2
Tc=20℃
Tc=40℃
1
Tc=60℃
0
0
0
20
40
60
80
0
100
20
60
80
100
Forward Current [mA]
Forward Current [mA]
Peak Wavelength vs. Case Temperature
Threshold Current vs. Case Temperature
476
80
●:Type1
▲:Type2
75
Peak Wavelength [nm]
Threshold Current [mA]
40
70
65
60
55
50
474
472
470
45
40
468
15
20
25 30
35
40
45
50 55
60
65
15
20 25
Case Temperature [℃]
60 65
Relative Optical Intensity
Relative Optical Intensity
50 55
Spectrum
θ//
θ⊥
-20
40 45
Case Temperature [℃]
Far Field Pattern
-40
30 35
0
20
468
40
470
472
474
Wavelength [nm]
Angle [°]
-2-
476
478
NICHIA
Product Guide( UTZ-SC0056_1 )
Cautions
(1) Safety of Laser light
Laser beam are extremely dangerous to human eyes. Never look at laser
beam directly and/or through optical lens. When handling the LDs, wear
appropriate safety glasses to prevent laser light, even any reflections from
entering to the eye. Focused laser beam through optical instruments will
increase the chance of eye hazard.
Nichia LDs are classified in Class 3B of IEC60825-1 and 21 CFR Part
1040.10 Safety Standards. It is absolutely necessary to take overall safety
measures against User's modules, equipment and systems into which Nichia
LDs are incorporated and/or integrated.
(2) Operating method
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,
the LD will require more operation current to maintain same output power as it degrades. In order to maintain output
power, use of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation
current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering
and/or overshooting in the Circuit.
(3) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(4) Absolute Maximum Rating
Active layer of LDs shall have high current density and generate high electric field during its operation. In order to
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
(5) Others
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales
staff in advance for information on the applications in which exceptional quality and reliability are required,
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support
systems and safety devices).
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-