NICHIA NDHV220APA

[ UTZ-SC0055_2 ]
Violet Laser Diode
NDHV220APA
Outline Dimension
Features
• Optical Output Power: 200mW
• Multi Transverse Mode
• Can Type: φ 5.6 with Photo Diode
Unit (mm)
+
0 3
0
0.
-
(
1.6
)
Φ
Φ
5.6
(90°
)
Absolute Maximum Ratings
(Tc=25°C)
Absolute Maximum
Item
Symbol
Unit
Ratings
Optical Output Power
Po
250
mW
LD Reverse Voltage
Vr (LD)
5
V
PD Reverse Voltage
Vr (PD)
20
V
Storage Temperature
Tstg
-35 ~ 85
°C
Operating Case Temperature
Tc
* 0 ~ 30
°C
* Operating Temperature is recommended within 20 ~ 30 °C range.
Initial Electrical/Optical Characteristics
Emitting Point
(0.4)
1.2±0.1
2.3±0.2
Φ 3.55±0.1
Emitting Point
6.5±1.0
(1.3)
Reference Plane
3×Φ 0.45±0.1
3
(Tc=25°C)
Item
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
Peak Wavelength
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
CW
Po=200mW
CW
Po=200mW
CW
Po=200mW
Po
λp
Ith
Iop
η
Vop
θ//
θ⊥
400
1.0
8
35
405
100
230
1.5
4.1
16
42
200
410
130
270
2.0
4.6
26
55
mW
nm
mA
mA
W/A
V
deg.
deg.
0.25±0.03
Z+
Φ 4.2±0.2
X+
1
2
Φ 2.0±0.2
Y+
Pin Connection
2
1
PD
Beam Divergence
Po=200mW
Full Angle (1/e2)
3
Emission Point
Angle Po=200mW
deg.
±5
∆θ⊥
Accuracy
Monitor Current*
Po=200mW
Im
0.4
0.8
1.2
mA
* Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
The above specifications are for reference purpose only and subjected to change without prior notice.
Safety of Laser light
Laser Light can damege the human eyes and skin. Do not expose the eye or skin to any
laser light directly and/or through optical lens. When handling the LDs, wear appropriate
safety glasses to prevent laser light, even any reflections from entering to the eye. Focused
laser beam through optical instruments will increase the chance of eye hazard.
These LDs are classified in Class 4 of IEC60825-1 and 21 CFR Part 1040.10 Safety
Standards. It is absolutely necessary to take overall safety measures against User's
modules, equipment and systems into which Nichia LDs are incorporated and/or integrated.
NICHIA CORPORATION
http://www.nichia.co.jp
LD
DANGER
VISIBLE AND/OR INVISIBLE
LASER RADIATION-AVOID EYE
OR SKIN EXPOSURE TO DIRECT
OR SCATTERED RADIATION
MAXIMUM OUTPUT 1W
WAVELENGTH 360~500nm
CLASS IV LASER PRODUCT
1. LD Anode
2. PD Anode
3. Common
VISIBLE AND/OR
INVISIBLE
LASER DIODE
AVOID EXPOSURE
Visible and/or invisible
Laser Radiation is
emi tted fr om thi s
aperture
This product is comply with 21 CFR Part 1040.10
Manufactured by NICHIA HQP
491.OKA KAMINAKA-CHO ANAN, TOKUSHIMA 774-8601 JAPAN
HEAD OFFICE
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV.
13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU,
TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
Glass Thickness
0.4±0.1
1.0±0.1
[ UTZ-SC0055_2 ]
Typical Characteristics
-2-
[ UTZ-SC0055_2 ]
Cautions
(1) Operating method
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also, the
LD will require more operation current to maintain same output power as it degrades. In order to maintain output power, use
of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering and/or
overshooting in the Circuit.
(2) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(3) Absolute Maximum Rating
Active layer of LDs shall have high current density and generate high electric field during its operation. In order to
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
(4) Others
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office equipment,
communications equipment, measurement instruments and household appliances). Consult Nichia’s sales staff in advance
for information on the applications in which exceptional quality and reliability are required, particularly when the failure or
malfunction of the LDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters,
nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices).
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design. Prior
to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy needs of, and
provides the features required by the Circuit and any related modules, equipment and/or systems.
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-