GE12 10 ~ 15W AC-DC Single Output Interchangeable Wall-mounted type series Features : Interchangeable AC plugs (plug kit sold seperately) Universal AC input / Full range No load power consumption< 0.3W ErP step2 compliant Meet EISA 2007 (Energy Independence and Security Act) for 5~24V Class power (without earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Pass LPS Approvals: UL / CUL / TUV / CCC / CB / FCC / CE / C-Tick 2 years warranty AC INLET PLUG TYPE ORDER NO. Australian type U.K type European type US type Mix four type AC plug-AU AC plug-UK AC plug-EU AC plug-US AC plug-MIX DC VOLTAGE OUTPUT Note.2 5V GE12 I 24-P1J I I I I GE12 I 18-P1J I I I I GE12 I 15-P1J I I GE12 I 12-P1J I I I I GE12 I 09-P1J FRA012-S07- I FRA012-S09- I FRA012-S12- I FRA012-S15- I FRA012-S18- I FRA012-S24- I 7.5V 9V 12V 15V 18V 24V 0.625A RATED CURRENT 2.0A 1.33A 1.33A 1.0A 0.8A 0.83A CURRENT RANGE 0 ~ 2.0A 0 ~ 1.33A 0 ~ 1.33A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A RATED POWER 10W 10W 12W 12W 12W 15W 15W 75mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p RIPPLE & NOISE (max.) Note.3 50mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 3.0% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION Note.6 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 3.0% SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC FREQUENCY RANGE INPUT I I GE12 I 07-P1J I I FRA012-S05- I I I SAFETY MODEL NO. I I I I POWER SUPPLY MAIN BODY ORDER NO. GE12 I 05-P1J I I I I SPECIFICATION 4000ms, 100ms, 10ms / 115VAC at full load 47 ~ 63Hz EFFICIENCY (Typ.) 74% 77% AC CURRENT 0.4A / 100VAC 0.25A / 230VAC INRUSH CURRENT (max.) COLD START 40A / 100VAC LEAKAGE CURRENT (max.) 0.25mA / 240VAC 110% ~ 200% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVERLOAD PROTECTION 79% 81% 82% 83% 83% 80A / 230VAC OVER VOLTAGE 115% ~ 135% Protection type : Clamp by zener diode WORKING TEMP. -10 ~ +50 WORKING HUMIDITY 20% ~ 90% RH non-condensing (Refer to "Derating Curve") ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03% / (0 ~ 40 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMC EMISSION EMC IMMUNITY LIFE OTHERS I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 2 years : 100% load 30 , 8 hours / day MTBF 100Khrs min. DIMENSION PACKING 70.7*40*38.8mm (L*W*H) 97g ; 60pcs / 6.88kg / CARTON DC OUTPUT PLUG CONNECTOR CABLE NOTE UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved MIL-HDBK-217F (25 ) Standard type P1J: 2.1 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requested See page2 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load 7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug. File Name:GE12-SPEC 2011-06-14 GE12 10 ~ 15W AC-DC Single Output Interchangeable Wall-mounted type Mechanical Specification series Unit:mm AWM2468 20AWG*2C 1500 50mm 40 ID 2.1 x OD 5.5 C"+" 11 0.5mm 70.7 Plug Assignment Standard plug: P1J P/N OUTPUT CENTER + 29.8 38.8 P1J Derating Curve Static Characteristics 100 90 80 75 70 50 -10 LOAD (%) LOAD (%) 100 10 20 30 Ta ( 40 50 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 ) File Name:GE12-SPEC 2011-06-14