LM96000 Hardware Monitor with Integrated Fan Control General Description The LM96000, hardware monitor, has a two wire digital interface compatible with SMBus 2.0. Using an 8-bit Σ∆ ADC, the LM96000 measures: – the temperature of two remote diode connected transistors as well as its own die – the VCCP, 2.5V, 3.3VSBY, 5.0V, and 12V supplies (internal scaling resistors). To set fan speed, the LM96000 has three PWM outputs that are each controlled by one of three temperature zones. High and low PWM frequency ranges are supported. The LM96000 includes a digital filter that can be invoked to smooth temperature readings for better control of fan speed. The LM96000 has four tachometer inputs to measure fan speed. Limit and status registers for all measured values are included. Features n 2-wire, SMBus 2.0 compliant, serial digital interface n 8-bit Σ∆ ADC n Monitors VCCP, 2.5V, 3.3 VSBY, 5.0V, and 12V motherboard/processor supplies n Monitors 2 remote thermal diodes n Programmable autonomous fan control based on temperature readings n n n n n n n n Noise filtering of temperature reading for fan control 1.0˚C digital temperature sensor resolution 3 PWM fan speed control outputs Provides high and low PWM frequency ranges 4 fan tachometer inputs Monitors 5 VID control lines 24-pin TSSOP package XOR-tree test mode Key Specifications Voltage Measurement Accuracy Resolution Temperature Sensor Accuracy Temperature Range — LM96000 Operational — Remote Temp Accuracy n Power Supply Voltage n Power Supply Current n n n n ± 2% FS (max) 8-bits, 1˚C ± 3˚C (max) 0˚C to +85˚C 0˚C to +125˚C +3.0V to +3.6V 0.53 mA Applications n Desktop PC n Microprocessor based equipment (e.g. Base-stations, Routers, ATMs, Point of Sales) Block Diagram 20084601 © 2004 National Semiconductor Corporation DS200846 www.national.com LM96000 Hardware Monitor with Integrated Fan Control November 2004 24 Pin TSSOP 20084602 NS Package MTC24E Top View LM96000CIMT (61 units per rail), or LM96000CIMTX (2500 units per tape and reel) Symbol Pin Type SMBDAT 1 Digital I/O (Open-Drain) System Management Bus Data. Open-drain output. 5V tolerant, SMBus 2.0 compliant. SMBCLK 2 Digital Input System Management Bus Clock. Tied to Open-drain output. 5V tolerant, SMBus 2.0 compliant. VID0 5 Digital Input Voltage identification signal from the processor. This value is read in the VID0–VID4 Status Register. VID1 6 Digital Input Voltage identification signal from the processor. This value is read in the VID0–VID4 Status Register. VID2 7 Digital Input Voltage identification signal from the processor. This value is read in the VID0–VID4 Status Register. VID3 8 Digital Input Voltage identification signal from the processor. This value is read in the VID0–VID4 Status Register. VID4 19 Digital Input Voltage identification signal from the processor. This value is read in the VID0–VID4 Status Register. 3.3V 4 POWER +3.3V pin. Can be powered by +3.3V Standby power if monitoring in low power states is required. This pin also serves as the analog input to monitor the 3.3V supply. This pin should be bypassed with a 0.1µf capacitor in parallel with 100pf. A bulk capacitance of approximately 10µf needs to be in the near vicinity of the LM96000. Power Processor VID Lines SMBus Pin Descriptions Voltage Inputs LM96000 Connection Diagram www.national.com Name and Function/Connection GND 3 GROUND 5V 20 Analog Input Analog input for +5V monitoring. Ground for all analog and digital circuitry. 12V 21 Analog Input Analog input for +12V monitoring. 2.5V 22 Analog Input Analog input for +2.5V monitoring. VCCP_IN 23 Analog Input Analog input for VCCP (processor voltage) monitoring. 2 Remote Fan Tachometer Inputs Fan Control (Continued) Symbol Pin Remote1+ 18 Remote Thermal Positive input (current source) from the first remote thermal diode. Diode Positive Serves as the positive input into the A/D. Connected to Input THERMDA pin of Pentium processor or the base of a diode connected MMBT3904 NPN transistor. Type Name and Function/Connection Remote1− 17 Remote Thermal Negative input (current sink) from the first remote thermal diode. Diode Negative Serves as the negative input into the A/D. Connected to Input THERMDC pin of Pentium processor or the emmiter of a diode connected MMBT3904 NPN transistor. Remote2+ 16 Remote Thermal Positive input (current source) from the first remote thermal diode. Diode Positive Serves as the positive input into the A/D. Connected to Output THERMDA pin of Pentium processor or the base of a diode connected MMBT3904 NPN transistor. Remote2− 15 Remote Thermal Negative input (current sink) from the first remote thermal diode. Diode Negative Serves as the negative input into the A/D. Connected to Input THERMDC pin of Pentium processor or the emmiter of a diode connected MMBT3904 NPN transistor. TACH1 11 Digital Input Input for monitoring tachometer output of fan 1. TACH2 12 Digital Input Input for monitoring tachometer output of fan 2. TACH3 9 Digital Input Input for monitoring tachometer output of fan 3. TACH4/Address Select 14 Digital Input Input for monitoring tachometer output of fan 4. If in Address Select Mode, determines the SMBus address of the LM96000. PWM1/xTest Out 24 Digital Open-Drain Fan speed control 1. When in XOR tree test mode, functions as Output XOR Tree output. PWM2 10 Digital Open-Drain Fan speed control 2. Output PWM3/Address Enable 13 Digital Open-Drain Fan speed control 3. Pull to ground at power on to enable Output Address Select Mode (Address Select pin controls SMBus address of the device). 3 www.national.com LM96000 Pin Descriptions LM96000 Absolute Maximum Ratings (Notes 1, 2) Storage Temperature If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Soldering process must comply with National’s reflow temperature profile specifications. Refer to www.national.com/packaging/. (Note 6) −65˚C to +150˚C Supply Voltage, V+ −0.5V to 6.0V Voltage on Any Digital Input or Output Pin −0.5V to 6.0V Operating Ratings (Notes 1, 2) Voltage on 12V Analog Input −0.5V to 16V LM96000 Operating Temperature Range Voltage on 5V Analog Input −0.5V to 6.66V Remote Diode Temperature Range Voltage on Remote1+, Remote2+, −0.5V to (V+ + 0.05V) Voltage on Other Analog Inputs Supply Voltage (3.3V nominal) ± 1 mA Current on Remote1−, Remote2− Package Dissipation at TA = 25˚C +5V VIN −0.05V to 6.66V 3.0V to 4.4V VCCP_IN and All Other Inputs −0.05V to (V+ + 0.05V) ESD Susceptibility (Note 4) Machine Model −0.05V to 16V +3.3V VIN See (Note 5) Human Body Model +3.0V to +3.6V +12V VIN ± 5 mA ± 20 mA Package Input Current (Note 3) 0˚C ≤ TD ≤ +125˚C VIN Voltage Range −0.5V to 6.0V Input Current on Any Pin (Note 3) 0˚C ≤ TA ≤ +85˚C VID0–VID4 2500V −0.05V to 5.5V Typical Supply Current 250V 0.53 mA DC Electrical Characteristics The following specifications apply for V+ = 3.0V to 3.6V, and all analog input source impedance RS = 50Ω unless otherwise specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. TA is the ambient temperature of the LM96000; TJ is the junction temperature of the LM96000; TD is the thermal diode junction temperature. Symbol Parameter Conditions Typical (Note 7) Limits (Note 8) Units (Limits) Converting, Interface and Fans Inactive, Peak Current 1.8 3.5 mA (max) Converting, Interface and Fans Inactive, Average Current 0.53 POWER SUPPLY CHARACTERISTICS Supply Current (Note 9) Power-On Reset Threshold Voltage mA 1.6 V (min) 2.8 V (max) TEMPERATURE TO DIGITAL CONVERTER CHARACTERISTICS Resolution 1 8 ±1 ± 2.5 ±3 ±4 ±3 High Level 188 280 Low Level 11.75 Temperature Accuracy (See (Note 10) for Thermal TD=25˚C Diode Processor Type) TD=0˚C to 100˚C ±1 TD=100˚C to 125˚C Temperature Accuracy using Internal Diode (Note 11) IDS External Diode Current Source ˚C Bits External Diode Current Ratio ˚C (max) ˚C (max) ˚C (max) ˚C (max) µA (max) µA 16 ANALOG TO DIGITAL CONVERTER CHARACTERISTICS ±2 TUE Total Unadjusted Error(Note 12) DNL Differential Non-linearity 1 Power Supply Sensitivity ±1 Total Monitoring Cycle Time (Note 13) www.national.com All Voltage and Temperature readings 4 182 %FS (max) LSB %/V 200 ms (max) (Continued) The following specifications apply for V+ = 3.0V to 3.6V, and all analog input source impedance RS = 50Ω unless otherwise specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. TA is the ambient temperature of the LM96000; TJ is the junction temperature of the LM96000; TD is the thermal diode junction temperature. Symbol Parameter Conditions Input Resistance, all analog inputs Typical (Note 7) 210 Limits (Note 8) Units (Limits) 140 kΩ (min) 400 kΩ (max) 8 mA (min) DIGITAL OUTPUT: PWM1, PWM2, PWM3, XTESTOUT IOL Logic Low Sink Current VOL=0.4V VOL Logic Low Level IOUT = +8 mA 0.4 V (max) 0.4V V (max) 10 µA (max) SMBUS OPEN-DRAIN OUTPUT: SMBDAT VOL Logic Low Output Voltage IOUT = +4 mA IOH High Level Output Current VOUT = V+ 0.1 SMBUS INPUTS: SMBCLK. SMBDAT VIH Logic Input High Voltage 2.1 V (min) VIL Logic Input Low Voltage 0.8 V (max) VHYST Logic Input Hysteresis Voltage 300 mV DIGITAL INPUTS: ALL VIH Logic Input High Voltage 2.1 V (min) 0.8 V (max) VIL Logic Input Low Voltage VTH Logic Input Threshold Voltage IIH Logic High Input Current VIN = V+ 0.005 10 µA (max) IIL Logic Low Input Current VIN = GND −0.005 −10 µA (max) CIN Digital Input Capacitance 1.5 V 20 pF AC Electrical Characteristics The following specifications apply for V+ = 3.0V to 3.6V unless otherwise specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. Symbol Parameter Conditions Typical (Note 7) Limits (Note 8) Units (Limits) Fan Count Accuracy ± 10 % (max) Fan Full-Scale Count 65536 (max) 1.4 sec (max) ± 10 % (max) TACHOMETER ACCURACY Fan Counter Clock Frequency 90 Fan Count Conversion Time 0.7 kHz FAN PWM OUTPUT Frequency Setting Accuracy Frequency Range Duty-Cycle Range 10 30 Low frequency range Hz kHz 0 to 100 % (max) Duty-Cycle Resolution (8-bits) 0.390625 % Spin-Up Time Interval Range 100 4000 ms ms Spin-Up Time Interval Accuracy ± 10 % (max) ± 10 % (max) SPIKE SMOOTHING FILTER Time Interval Deviation Time Interval Range 35 0.8 sec sec SMBUS TIMING CHARACTERISTICS fSMB SMBus Operating Frequency 10 100 5 kHz (min) kHz (max) www.national.com LM96000 DC Electrical Characteristics LM96000 AC Electrical Characteristics (Continued) The following specifications apply for V+ = 3.0V to 3.6V unless otherwise specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. Symbol Parameter fBUF Conditions Typical (Note 7) Limits (Note 8) Units (Limits) SMBus Free Time Between Stop And Start Condition 4.7 µs (min) tHD_STA Hold Time After (Repeated) Start Condition (after this period, the first clock is generated) 4.0 µs (min) tSU:STA Repeated Start Condition Setup Time 4.7 µs (min) tSU:STO Stop Condition Setup Time 4.0 µs (min) tHD:DAT Data Output Hold Time 300 ns (min) 930 ns (max) tSU:DAT Data Input Setup Time 250 ns (min) tTIMEOUT Data And Clock Low Time To Reset Of SMBus Interface Logic(Note 14) 25 35 ms (min) ms (max) tLOW Clock Low Period 4.7 µs (min) tHIGH Clock High Period 4.0 50 µs (min) µs (max) tF Clock/Data Fall Time 300 ns (max) tR Clock/Data Rise Time tPOR Time from Power-On-Reset to LM96000 Reset and Operational V+ > 2.8V 1000 ns (max) 500 ms (max) 20084603 Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND, unless otherwise noted. Note 3: When the input voltage (VIN) at any pin exceeds the power supplies (VIN < GND or VIN > V+ ), the current at that pin should be limited to 5mA. The 20mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 5mA to four. Parasitic components and/or ESD protection circuitry are shown below for the LM96000’s pins. The nominal breakdown voltage the zener is 6.5V. Care should be taken not to forward bias the parasitic diode D1 present on pins D+ and D−. Doing so by more that 50 mV may corrupt temperature measurements. SNP stands for snap-back device. www.national.com 6 Pin Name Circuit 1 SMBDAT A 2 SMBCLK 3 GND 4 3.3V 5 VID0 6 VID1 7 VID2 8 VID3 9 TACH3 10 PWM2 11 TACH1 12 TACH2 13 PWM3/AddEnable 14 TACH4/AddSel 15 REMOTE2− C 16 REMOTE2+ D 17 REMOTE1− C 18 REMOTE1+ D 19 VID4 A 20 5V E 21 12V 22 2.5V 23 VCCP_IN 24 PWM1/xTEXTOUT LM96000 Pin # All Input Circuits B Circuit A A Circuit B Circuit C Circuit D A Circuit E Note 4: Human body model, 100pF discharged through a 1.5kΩ resistor. Machine model, 200pF discharged directly into each pin. Note 5: Thermal resistance junction-to-ambient when attached to a double-sided printed circuit board with 1 oz. foil is 113 ˚C/W. Note 6: Reflow temperature profiles are different for packages containing lead (Pb) than for those that do not. Note 7: Typicals are at TA = 25˚C and represent most likely parametric norm. Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level). Note 9: The average current can be calculated from the peak current using the following equation: Quiescent current will not increase substantially with an SMBus transaction. Note 10: The accuracy of the LM96000CIMT is guaranteed when using the thermal diode of Intel Pentium 4 90nm processors or any thermal diode with a non-ideality of 1.011 and series resistance of 3.33Ω. When using a 2N3904 type transistor as a thermal diode the error band will be typically shifted by -?˚C. Note 11: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power dissipation of the LM96000 and the thermal resistance. See (Note 5) for the thermal resistance to be used in the self-heating calculation. Note 12: TUE , total unadjusted error, includes ADC gain, offset, linearity and reference errors. TUE is defined as the "actual Vin" to achieve a given code transition minus the "theoretical Vin" for the same code. Therefore, a positive error indicates that the input voltage is greater than the theoretical input voltage for a given code. If the theoretical input voltage was applied to an LM96000 that has positive error, the LM96000’s reading would be less than the theoretical. Note 13: This specification is provided only to indicate how often temperature and voltage data is updated. The LM96000 can be read at any time without regard to conversion state (and will yield last conversion result). 7 www.national.com LM96000 Note 14: Holding the SMBDAT and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM96000’s SMBus state machine, therefore setting the SMBDAT pin to a high impedance state. Functional Description 1.0 SMBUS The LM96000 is compatible with devices that are compliant to the SMBus 2.0 specification. More information on this bus can be found at: http://www.smbus.org/. Compatibility of SMBus2.0 to other buses is discussed in the SMBus 2.0 specification. 1.1 Addressing LM96000 is designed to be used primarily in desktop systems that require only one monitoring device. If only one LM96000 is used on the motherboard, the designer should be sure that the Address Enable/PWM3 pin is High during the first SMBus communication addressing the LM96000. Address Enable/PWM3 is an open drain I/O pin that at power-on defaults to the input state of Address Enable. A maximum of 10k pull-up resistance on Address Enable/PWM3 is required to assure that the SMBus address of the device will be locked at 010 1110b, which is the default address of the LM96000. During the first SMBus communication TACH4 and PWM3 can be used to change the SMBus address of the LM96000 to 0101101b or 0101100b. LM96000 address selection procedure: A 10 kΩ pull-down resistor to ground on the Address Enable/PWM3 pin is required. Upon power up, the LM96000 will be placed into Address Enable mode and assign itself an SMBus address according to the state of the Address Select input. The LM96000 will latch the address during the first valid SMBus transaction in which the first five bits of the targeted address match those of the LM96000 address, 0 1011b. This feature eliminates the possibility of a glitch on the SMBus interfering with address selection. When the PWM3/Address Enable pin is not used to change the SMBus address of the LM96000, it will remain in a high state until the first communication with the LM96000. After the first SMBus transaction is completed PWM3 and TACH4 will return to normal operation. Address Enable Address Select Board Implementation SMBus Address 0 0 Pulled to ground through a 10 kΩ resistor 010 1100b, 2Ch 0 1 Pulled to 3.3V or to GND through a 10 kΩ resistor 010 1101b, 2Dh 1 X Pulled to 3.3V through a 10 kΩ resistor 010 1110b, 2Eh In this way, up to three LM96000 devices can exists on an SMBus at any time. Multiple LM96000 devices can be used to monitor additional processors and temperature zones. When using the non-default addresses additional circuitry will be required if TACH4 and PWM3 require to function correctly. Such circuitry could consist of GPIO pins from a micro-controller. During the first communication the micro-controller would drive the Address Enable and Address Select pins to the proper state for the required address. After the first SMBus communication the micro-controller would drive it’s pins into TRISTATE allowing TACH4 and PWM3 to operate correctly. 20084604 2.0 FAN REGISTER DEVICE SET-UP The BIOS will follow the following steps to configure the fan registers on the LM96000. The registers corresponding to each function are listed. All steps may not be necessary if default values are acceptable. Regardless of all changes made by the BIOS to the fan limit and parameter registers during configuration, the LM96000 will continue to operate based on default values until the START bit (bit 0), in the Ready/Lock/Start/Override register (address 40h), is set. Once the fan mode is updated, by setting the START bit to 1, the LM96000 will operate using the values that were set by the BIOS in the fan control limit and parameter registers (adress 5Ch through 6Eh). www.national.com 8 1. LM96000 Functional Description (Continued) Set limits and parameters (not necessarily in this order): – [5F-61h] Set PWM frequencies and auto fan control range. – [62-63h] Set spike smoothing and min/off. – [5C-5Eh] Set the fan spin-up delays. – [5C-5Eh] Match each fan with a corresponding thermal zone. – [67-69h] Set the fan temperature limits. – [6A-6Ch] Set the temperature absolute limits. – [64-66h] Set the PWM minimum duty cycle. 2. 3. – [6D-6Eh] Set the temperature Hysteresis values. [40h] Set bit 0 (START) to update fan control and limit register values and start fan control based on these new values. [40h] Set bit 1 (LOCK) to lock the fan limit and parameter registers (optional). 3.0 AUTO FAN CONTROL OPERATING MODE The LM96000 includes the circuitry for automatic fan control. In Auto Fan Mode, the LM96000 will automatically adjust the PWM duty cycle of the PWM outputs. PWM outputs are assigned to a thermal zone based on the fan configuration registers. It is possible to have more than one PWM output assigned to a thermal zone. For example, PWM outputs 2 and 3, connected to two chassis fans, may both be controlled by thermal zone 2. At any time, the temperature of a zone exceeds its absolute limit, all PWM outputs will go to 100% duty cycle to provide maximum cooling to the system. 4.0 REGISTER SET Register Read/ Register Address Write Name Bit 7 Bit 6 (MSB) Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Lock? Value 20h R 2.5V 7 6 5 4 3 2 1 0 N/A 21h R VCCP_IN 7 6 5 4 3 2 1 0 N/A 22h R 3.3V 7 6 5 4 3 2 1 0 N/A 23h R 5V 7 6 5 4 3 2 1 0 N/A 24h R 12V 7 6 5 4 3 2 1 0 N/A 25h R Processor (Zone1) Temp 7 6 5 4 3 2 1 0 N/A 26h R Internal (Zone2) Temp 7 6 5 4 3 2 1 0 N/A 27h R Remote (Zone3) Temp 7 6 5 4 3 2 1 0 N/A 28h R Tach1 LSB 7 6 5 4 3 2 29h R Tach1 MSB 15 14 13 12 11 10 2Ah R Tach2 LSB 7 6 5 4 3 2 2Bh R Tach2 MSB 15 14 13 12 11 10 2Ch R Tach3 LSB 7 6 5 4 3 2 2Dh R Tach3 MSB 15 14 13 12 11 10 2Eh R Tach4 LSB 7 6 5 4 3 2 2Fh R Tach4 MSB 15 14 13 12 11 10 9 8 N/A 30h R/W Fan1 Current PWM Duty 7 6 5 4 3 2 1 0 N/A 31h R/W Fan2 Current PWM Duty 7 6 5 4 3 2 1 0 N/A 32h R/W Fan3 Current PWM Duty 7 6 5 4 3 2 1 0 N/A 3Eh R Company ID 7 6 5 4 3 2 1 0 01h 3Fh R Version/Stepping VER3 VER2 VER1 VER0 STP3 STP2 40h R/W Ready/Lock/Start/Override RES RES RES RES 41h R Interrupt Status Register 1 ERR ZN3 ZN2 ZN1 5V 42h R Interrupt Status Register 2 ERR2 ERR1 FAN4 FAN3 FAN2 43h R VID0–4 44h R/W 45h R/W 46h LEVEL1 LEVEL0 9 8 LEVEL1 LEVEL0 9 8 LEVEL1 LEVEL0 9 8 LEVEL1 LEVEL0 N/A N/A N/A N/A N/A N/A N/A STP1 STP0 68h LOCK START 00h 3.3V VCCP 2.5V 00h FAN1 RES 12V 00h N/A OVRID READY RES RES RES VID4 VID3 VID2 VID1 VID0 2.5V Low Limit 7 6 5 4 3 2 1 0 00h 2.5V High Limit 7 6 5 4 3 2 1 0 FFh R/W VCCP Low Limit 7 6 5 4 3 2 1 0 00h 47h R/W VCCP High Limit 7 6 5 4 3 2 1 0 FFh 48h R/W 3.3V Low Limit 7 6 5 4 3 2 1 0 00h 9 www.national.com LM96000 Functional Description (Continued) Register Read/ Register Address Write Name Bit 7 Bit 6 (MSB) Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Lock? Value 49h R/W 3.3V High Limit 7 6 5 4 3 2 1 0 4Ah R/W 5V Low Limit 7 6 5 4 3 2 1 0 00h 4Bh R/W 5V High Limit 7 6 5 4 3 2 1 0 FFh 4Ch R/W 12V Low Limit 7 6 5 4 3 2 1 0 00h 4Dh R/W 12V High Limit 7 6 5 4 3 2 1 0 FFh 4Eh R/W Processor (Zone1) Low Temp 7 6 5 4 3 2 1 0 81h 4Fh R/W Processor (Zone1) High Temp 7 6 5 4 3 2 1 0 7Fh 50h R/W Internal (Zone2) Low Temp 7 6 5 4 3 2 1 0 81h 51h R/W Internal (Zone2) High Temp 7 6 5 4 3 2 1 0 7Fh 52h R/W Remote (Zone3) Low Temp 7 6 5 4 3 2 1 0 81h 53h R/W Remote (Zone3) High Temp 7 6 5 4 3 2 1 0 7Fh 54h R/W Tach1 Minimum LSB 7 6 5 4 3 2 1 0 FFh 55h R/W Tach1 Minimum MSB 15 14 13 12 11 10 9 8 FFh 56h R/W Tach2 Minimum LSB 7 6 5 4 3 2 1 0 FFh 57h R/W Tach2 Minimum MSB 15 14 13 12 11 10 9 8 FFh 58h R/W Tach3 Minimum LSB 7 6 5 4 3 2 1 0 FFh 59h R/W Tach3 Minimum MSB 15 14 13 12 11 10 9 8 FFh 5Ah R/W Tach4 Minimum LSB 7 6 5 4 3 2 1 0 FFh 5Bh R/W Tach4 Minimum MSB 15 14 13 12 11 10 9 8 FFh 5Ch R/W Fan1 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U 5Dh R/W Fan2 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U 5Eh R/W Fan3 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U 5Fh R/W Fan1 Range/Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U 60h R/W Fan2 Range/Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U 61h R/W Fan3 Range/Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U 62h R/W Min/Off, Zone1 Spike Smoothing OFF3 OFF2 OFF1 RES ZN1E ZN1-2 ZN1-1 ZN1-0 00H U 63h R/W Zone2, Zone3 Spike Smoothing ZN2E ZN2-2 ZN2-1 ZN2-0 ZN3E ZN3-2 ZN3-1 ZN3-0 00h U 64h R/W Fan1 PWM Minimum 7 6 5 4 3 2 1 0 80h U 65h R/W Fan2 PWM Minimum 7 6 5 4 3 2 1 0 80h U 66h R/W Fan3 PWM Minimum 7 6 5 4 3 2 1 0 80h U 67h R/W Zone1 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U 68h R/W Zone2 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U 69h R/W Zone3 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U 6Ah R/W Zone1 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h U 6Bh R/W Zone2 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h U 6Ch R/W Zone3 Temp Absolute Limit 7 6 5 4 3 2 1 0 64h U 6Dh R/W Zone1, Zone2 Hysteresis H1-3 H1-2 H1-1 H1-0 H2-3 H2-2 H2-1 H2-0 44h U 6Eh R/W Zone3 Hysteresis H3-3 H3-2 H3-1 H3-0 RES RES RES RES 40h U www.national.com 10 FFh (Continued) Register Read/ Register Address Write Name Bit 7 Bit 6 (MSB) Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) RES Default Lock? Value 6Fh R/W XOR Test Tree Enable RES RES RES RES RES RES XEN 00h 74h R/W Tach Monitor Mode RES RES T3/4-1 T3/4-0 T2-1 T2-0 T1-1 T1-0 00h 75h R/W Fan Spin-up Mode RES RES RES PWM3 SU PWM2 SU PWM1 SU 7h RES RES U U Note: Reserved bits will always return 0 when read. 4.1 Register 20-24h: Voltage Reading Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 20h R 2.5V 7 6 5 4 3 2 1 0 N/A 21h R VCCP 7 6 5 4 3 2 1 0 N/A 22h R 3.3V 7 6 5 4 3 2 1 0 N/A 23h R 5V 7 6 5 4 3 2 1 0 N/A 24h R 12V 7 6 5 4 3 2 1 0 N/A The Register Names difine the typical input voltage at which the reading is 3⁄4 full scale or C0h. The Voltage Reading registers are updated automatically by the LM96000 at a minimum frequency of 4 Hz. These registers are read only — a write to these registers has no effect. 4.2 Register 25-27h: Temperature Reading Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 25h R Processor (Zone1) Temp 7 6 5 4 3 2 1 0 N/A 26h R Internal (Zone2) Temp 7 6 5 4 3 2 1 0 N/A 27h R Remote (Zone3) Temp 7 6 5 4 3 2 1 0 N/A The Temperature Reading registers reflect the current temperatures of the internal and remote diodes. Processor (Zone1) Temp register reports the temperature measured by the thermal diode connected to the Remote1− and Remote1+ pins, Remote (Zone3) Temp register reports the temperature measured by the thermal diode connected to the the Remote2− and Remote2+ pins, and the Internal (Zone2) Temp register reports the temperature measured by the internal (junction) temperature sensor. Temperatures are represented as 8 bit, 2’s complement, signed numbers, in Celsius, as shown below in Table 1. The Temperature Reading register will return a value of 80h if the remote diode pins are not used by the board designer or are not functioning properly. This reading will cause the zone limit bit(s) (bits 6 and 4) in the Interrupt Status Register (41h) and the remote diode fault status bit(s) (bit 6 or 7) in the Interrupt Status Register 2 (42h) to be set. The Temperature Reading registers are updated automatically by the LM96000 at a minimum frequency of 4 Hz. These registers are read only — a write to these registers has no effect. TABLE 1. Temperature vs Register Reading Temperature Reading (Dec) Reading (Hex) −127˚C −127 81h . . . . . . . . . −50˚C −50 CEh 11 www.national.com LM96000 Functional Description LM96000 Functional Description (Continued) TABLE 1. Temperature vs Register Reading (Continued) Temperature Reading (Dec) Reading (Hex) . . . . . . . . . 0˚C 0 00h . . . . . . . . . 127˚C 127 7Fh (SENSOR ERROR) 80h 4.3 Register 28-2Fh: Fan Tachometer Reading Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 28h 29h R R Tach1 LSB Tach1 MSB 7 15 6 14 5 13 4 12 3 11 2 10 LEVEL1 9 LEVEL0 8 N/A N/A 2Ah 2Bh R R Tach2 LSB Tach2 MSB 7 15 6 14 5 13 4 12 3 11 2 10 LEVEL1 9 LEVEL0 8 N/A N/A 2Ch 2Dh R R Tach3 LSB Tach3 MSB 7 15 6 14 5 13 4 12 3 11 2 10 LEVEL1 9 LEVEL0 8 N/A N/A 2Eh 2Fh R R Tach4 LSB Tach4 MSB 7 15 6 14 5 13 4 12 3 11 2 10 LEVEL1 9 LEVEL0 8 N/A N/A The Fan Tachometer Reading registers contain the number of 11.111 µs periods (90 kHz) between full fan revolutions. The results are based on the time interval of two tachometer pulses, since most fans produce two tachometer pulses per full revolution. These registers will be updated at least once every second. The value, for each fan, is represented by a 16-bit unsigned number. The Fan Tachometer Reading registers will always return an accurate fan tachometer measurement, even when a fan is disabled or non-functional. The least two significant bits (LEVEL1 and LEVEL2) of the least significant byte are used to indicate the accuracy level of the tachometer reading. The accuracy ranges from most to least accurate. [LEVEL1:LEVEL2]=11indicates a most accurate value, [LEVEL1:LEVEL2]=01 indicates the least accurate value and [LEVEL1:LEVEL2]=00 is reserved for future use. FF FFh indicates that the fan is not spinning, or that the tachometer input is not connected to a valid signal. These registers are read only — a write to these registers has no effect. When the LSByte of the LM96000 16-bit register is read, the other byte (MSByte) is latched at the current value until it is read. At the end of the MSByte read the Fan Tachometer Reading registers are updated. During spin-up, the PWM duty cycle reported is 0%. 4.4 Register 30-32h: Current PWM Duty Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 30h R/W Fan1 Current PWM Duty 7 6 5 4 3 2 1 0 N/A 31h R/W Fan2 Current PWM Duty 7 6 5 4 3 2 1 0 N/A 32h R/W Fan3 Current PWM Duty 7 6 5 4 3 2 1 0 N/A The Current PWM Duty registers store the current duty cycle at each PWM output. At initial power-on, the PWM duty cycle is 100% and thus, when read, this register will return FFh. After the Ready/Lock/Start/Override register Start bit is set, this register and the PWM signals will be updated based on the algorithm described in the Auto Fan Control Operating Mode section. When read, the Current PWM Duty registers return the current PWM duty cycle. These registers are read only unless the fan is in manual (test) mode, in which case a write to these registers will directly control the PWM duty cycle for each fan. The PWM duty cycle is represented as shown in the following table. www.national.com Current Duty Value (Decimal) Value (Hex) 0% 0 00h 12 LM96000 Functional Description (Continued) Current Duty Value (Decimal) Value (Hex) 0.3922% 1 01h . . . . . . . . . 25.098% 64 40h . . . . . . . . . 50.196% 128 80h . . . . . . . . . 100% 255 FFh 4.5 Register 3Eh: Company ID Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 3Eh R Company ID 7 6 5 4 3 2 1 0 01h The company ID register contains the company identification number. For National Semiconductor this is 01h. This number is assigned by Intel and is a method for uniquely identifying the part manufacturer. This register is read only — a write to this register has no effect. 4.6 Register 3Fh: Version/Stepping Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 3Fh R Version/Stepping VER3 VER2 VER1 VER0 STP3 STP2 STP1 STP0 68h The four least significant bits of the Version/Stepping register [3.0] contain the current stepping of the LM96000 silicon. The four most significant bits [7.4] reflect the LM96000 base device number when set to a value of 0110b. For the LM96000, this register will read 01101000b (68h). Bit 3 of the stepping field is set to indicate that the LM96000 is a super-set of the LM85 family of products. The register is used by application software to identify which device in the hardware monitor family of ASICs has been implemented in the given system. Based on this information, software can determine which registers to read from and write to. Further, application software may use the current stepping to implement work-arounds for bugs found in a specific silicon stepping. This register is read only — a write to this register has no effect. 4.7 Register 40h: Ready/Lock/Start/Override Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 40h R/W Ready/Lock/Start/Override RES RES RES RES OVRID READY LOCK START 00h 13 www.national.com LM96000 Functional Description (Continued) Bit Name R/W Default Description 0 START R/W 0 When software writes a 1 to this bit, the LM96000 fan monitoring and PWM output control functions will use the values set in the fan control limit and parameter registers (address 5Ch through 6Eh). Before this bit is set, the LM96000 will not update the used register values, the default values will remain in effect. Whenever this bit is set to 0, the LM96000 fan monitoring and PWM output control functions use the default fan limits and parameters, regardless of the current values in the limit and parameter registers (5C through 6Eh). The LM96000 will preserve the values currently stored in the limit and parameter registers when this bit is set or cleared. This bit is not effected by the state of the Lock bit. It is expected that all limit and parameter registers will be set by BIOS or application software prior to setting this bit. 1 LOCK R/W 0 Setting this bit to 1 locks specified limit and parameter registers. Once this bit is set, limit and parameter registers become read only and will remain locked until the device is powered off. This register bit becomes read only once it is set. 2 READY R 0 The LM96000 sets this bit automatically after the part is fully powered up, has completed the power-up-reset process, and after all A/D converters are properly functioning. 3 OVRID R/W 4–7 Reserved R If this bit is set to 1, all PWM outputs will go to 100% duty cycle regardless of whether or not the lock bit is set. The OVRID bit has precedence over the disabled mode. Therefore, when OVRID is set the PWM will go to 100% even if the PWM is in the disabled mode. 0 Reserved 4.8 Register 41h: Interrupt Status Register 1 Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 41h R Interrupt Status 1 ERR ZN3 ZN2 ZN1 5V 3.3V VCCP 2.5V 00h The Interrupt Status Register 1 bits will be automatically set, by the LM96000, whenever a fault condition is detected. A fault condition is detected whenever a measured value is outside the window set by its limit registers. ZN3 and ZN1 bits will be set when a diode fault condition, such as a disconect or short, is detected. More than one fault may be indicated in the interrupt register when read. This register will hold a set bit(s) until the event is read by software. The contents of this register will be cleared (set to 0) automatically by the LM96000 after it is read by software, if the fault condition is no longer exists. Once set, the Interrupt Status Register 1 bits will remain set until a read event occurs, even if the fault condition no longer exists This register is read only — a write to this register has no effect. Bit Name R/W Default Description 0 2.5V_Error R 0 The LM96000 automatically sets this bit to 1 when the 2.5V input voltage is less than or equal to the limit set in the 2.5V Low Limit register or greater than the limit set in the 2.5V High Limit register. 1 VCCP_Error R 0 The LM96000 automatically sets this bit to 1 when the VCCP input voltage is less than or equal to the limit set in the VCCP Low Limit register or greater than the limit set in the VCCP High Limit register. 2 3.3V_Error R 0 The LM96000 automatically sets this bit to 1 when the 3.3V input voltage is less than or equal to the limit set in the 3.3V Low Limit register or greater than the limit set in the 3.3V High Limit register. 3 5V_Error R 0 The LM96000 automatically sets this bit to 1 when the 5V input voltage is less than or equal to the limit set in the 5V Low Limit register or greater than the limit set in the 5V High Limit register. www.national.com 14 LM96000 Functional Description (Continued) Bit Name R/W Default Description 4 Zone 1 Limit Exceeded R 0 The LM96000 automatically sets this bit to 1 when the temperature input measured by the Remote1− and Remote1+ inputs is less than or equal to the limit set in the Processor (Zone1) Low Temp register or more than the limit set in the Processor (Zone1) High Temp register. This bit will be set when a diode fault is detected. 5 Zone 2 Limit Exceeded R 0 The LM96000 automatically sets this bit to 1 when the temperature input measured by the internal temperature sensor is less than or equal to the limit set in the Internal (Zone2) Low Temp register or greater than the limit set in the Internal (Zone2) High Temp register. 6 Zone 3 Limit Exceeded R 0 The LM96000 automatically sets this bit to 1 when the temperature input measured by the Remote2− and Remote2+ inputs is less than or equal to the limit set in the Internal (Zone2) Low Temp register or greater than the limit set in the Remote (Zone3) High Temp register. This bit will be set when a diode fault is detected. 7 Error in Status Register 2 R 0 If there is a set bit in Status Register 2, this bit will be set to 1. 4.9 Register 42h: Interrupt Status Register 2 Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 42h R Interrupt Status Register 2 ERR2 ERR1 FAN4 FAN3 FAN2 FAN1 RES 12V 00h The Interrupt Status Register 2 bits will be automatically set, by the LM96000, whenever a fault condition is detected. Interrupt Status Register 2 identifies faults caused by temperature sensor error, fan speed droping below minimum set by the tachometer minimum register, the 12V input voltage going outside the window set by its limit registers. Interrupt Status Register 2 will hold a set bit until the event is read by software. The contents of this register will be cleared (set to 0) automatically by the LM96000 after it is ready by software, if fault condition no longer exists. Once set, the Interrupt Status Register 2 bits will remain set until a read event occurs, even if the fault no longer exists This register is read only — a write to this register has no effect. Bit Name R/W Default Description 0 +12V_Error R 0 The LM96000 automatically sets this bit to 1 when the 12V input voltage either falls below the limit set in the 12V Low Limit register or exceeds the limit set in the 12V High Limit register. 1 Reserved R 0 Reserved 2 Fan1 Stalled R 0 The LM96000 automatically sets this bit to 1 when the TACH1 input reading is above the value set in the Tach1 Minimum MSB and LSB registers. 3 Fan2 Stalled R 0 The LM96000 automatically sets this bit to 1 when the TACH2 input reading is above the value set in the Tach2 Minimum MSB and LSB registers. 4 Fan3 Stalled R 0 The LM96000 automatically sets this bit to 1 when the TACH3 input reading is above the value set in the Tach3 Minimum MSB and LSB registers. 5 Fan4 Stalled R 0 The LM96000 automatically sets this bit to 1 when the TACH4 input reading is above the value set in the Tach4 Minimum MSB and LSB registers. 6 Remote Diode 1 Fault R 0 The LM96000 automatically sets this bit to 1 when there is either a short or open circuit fault on the Remote1+ or Remote1− thermal diode input pins. A diode fault will also set bit 4, Diode 1 Zone Limit bit, of Interrupt Status Register 1. 15 www.national.com LM96000 Functional Description (Continued) Bit Name R/W Default Description 7 Remote Diode 2 Fault R 0 The LM96000 automatically sets this bit to 1 when there is either a short or open circuit fault on the Remote2+ or Remote2− thermal diode input pins. A diode fault will also set bit 6, Diode 2 Zone Limit bit, of Interrupt Status Register 1. 4.10 Register 43h: VID Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) 43h R VID0–4 RES RES RES VID4 VID3 VID2 VID1 VID0 Default Value The VID register contains the values of LM96000 VID0–VID4 input pins. This register indicates the status of the VID lines that interconnect the processor to the Voltage Regulator Module (VRM). Software uses the information in this register to determine the voltage that the processor is designed to operate at. With this information, software can then dynamically determine the correct values to place in the VCCP Low Limit and VCCP High Limit registers. This register is read only — a write to this register has no effect. 4.11 Registers 44-4Dh: Voltage Limit Registers Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 44h R/W 45h R/W 2.5V Low Limit 7 6 5 4 3 2 1 0 00h 2.5V High Limit 7 6 5 4 3 2 1 0 46h FFh R/W VCCP Low Limit 7 6 5 4 3 2 1 0 00h 47h R/W VCCP High Limit 7 6 5 4 3 2 1 0 FFh 48h R/W 3.3V Low Limit 7 6 5 4 3 2 1 0 00h 49h R/W 3.3V High Limit 7 6 5 4 3 2 1 0 FFh 4Ah R/W 5V Low Limit 7 6 5 4 3 2 1 0 00h 4Bh R/W 5V High Limit 7 6 5 4 3 2 1 0 FFh 4Ch R/W 12V Low Limit 7 6 5 4 3 2 1 0 00h 4Dh R/W 12V High Limit 7 6 5 4 3 2 1 0 FFh If a voltage input either exceeds the value set in the voltage high limit register or falls below the value set in the voltage low limit register, the corresponding bit will be set automatically by the LM96000 in the interrupt status registers (41-42h). Voltages are presented in the registers at 3⁄4 full scale for the nominal voltage, meaning that at nominal voltage, each input will be C0h, as shown in Table 2. Setting the Ready/Lock/Start/Override register Lock bit has no effect on these registers. TABLE 2. Voltage Limits vs Register Setting Input Nominal Voltage Register Setting at Nominal Voltage Maximum Voltage Register Reading at Maximum Voltage Minimum Voltage Register Reading at Minimum Voltage 2.5V VCCP 2.5V C0h 3.32V FFh 0V 00h 2.25V C0h 3.00V FFh 0V 00h 3.3V 3.3V C0h 4.38V FFh 3.0V AFh 5V 5.0V C0h 6.64V FFh 0V 00h 12V 12.0V C0h 16.00V FFh 0V 00h 4.12 Registers 4E-53h: Temperature Limit Registers Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 4Eh R/W Processor (Zone1) Low Temp 7 6 5 4 3 2 1 0 81h 4Fh R/W Processor (Zone1) High Temp 7 6 5 4 3 2 1 0 7Fh www.national.com 16 (Continued) Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 50h R/W Processor (Zone2) Low Temp 7 6 5 4 3 2 1 0 81h 51h R/W Processor (Zone2) High Temp 7 6 5 4 3 2 1 0 7Fh 52h R/W Processor (Zone3) Low Temp 7 6 5 4 3 2 1 0 81h 53h R/W Processor (Zone3) High Temp 7 6 5 4 3 2 1 0 7Fh If an external temperature input or the internal temperature sensor either exceeds the value set in the corresponding high limit register or falls below the value set in the corresponding low limit register, the corresponding bit will be set automatically by the LM96000 in the Interrupt Status Register 1 (41h). For example, if the temperature read from the Remote1− and Remote1+ inputs exceeds the Processor (Zone1) High Temp register limit setting, Interrupt Status Register 1 ZN1 bit will be set. The temperature limits in these registers are represented as 8 bit, 2’s complement, signed numbers in Celsius, as shown below in Table 3. Setting the Ready/Lock/Start/Override register Lock bit has no effect on these registers. TABLE 3. Temperature Limits vs Register Settings Temperature Reading (Decimal) Reading (Hex) −127˚C −127 81h . . . . . . . . . −50˚C −50 CEh . . . . . . . . . 0˚C 0 00h . . . . . . . . . 50˚C 50 32h . . . . . . . . . 127˚C 127 7Fh 4.13 Registers 54-5Bh: Fan Tachometer Low Limit Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 54h 55h R/W R/W Tach1 Minimum LSB Tach1 Minimum MSB 7 15 6 14 5 13 4 12 3 11 2 10 1 9 0 8 FFh FFh 56h 57h R/W R/W Tach2 Minimum LSB Tach2 Minimum MSB 7 15 6 14 5 13 4 12 3 11 2 10 1 9 0 8 FFh FFh 58h 59h R/W R/W Tach3 Minimum LSB Tach3 Minimum MSB 7 15 6 14 5 13 4 12 3 11 2 10 1 9 0 8 FFh FFh 5Ah 5Bh R/W R/W Tach4 Minimum LSB Tach4 Minimum MSB 7 15 6 14 5 13 4 12 3 11 2 10 1 9 0 8 FFh FFh The Fan Tachometer Low Limit registers indicate the tachometer reading under which the corresponding bit will be set in the Interrupt Status Register 2 register. In Auto Fan Control mode, the fan can run at low speeds, so care should be taken in software 17 www.national.com LM96000 Functional Description LM96000 Functional Description (Continued) to ensure that the limit is high enough not to cause sporadic alerts. The fan tachometer will not cause a bit to be set in Interrupt Status Register 2 if the current value in Current PWM Duty registers is 00h or if the fan 1 disabled via the Fan Configuration Register. Interrupts will never be generated for a fan if its minimum is set to FF FFh. Given the insignificance of Bit 0 and Bit 1, these bits could be programmed to remember which fan is which, as follows. Fan Bit 1 CPU 0 Bit 0 0 Memory 0 1 Chassis Front 1 0 Chassis Rear 1 1 Setting the Ready/Lock/Start/Override register Lock bit has no effect these registers. 4.14 Registers 5C-5Eh: Fan Configuration Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 5Ch R/W Fan1 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U 5Dh R/W Fan2 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U 5Eh R/W Fan3 Configuration ZON2 ZON1 ZON0 INV RES SPIN2 SPIN1 SPIN0 62h U This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. Bits [7:5] Zone/Mode Bits [7:5] of the Fan Configuration registers associate each fan with a temperature sensor. When in Auto Fan Mode the fan will be assigned to a zone, and its PWM duty cycle will be adjusted according to the temperature of that zone. If ‘Hottest’ option is selected (101 or 110), the fan will be controlled by the hottest of zones 2 and 3, or of zones 1, 2, and 3. To determine the ‘Hottest’ zone the PWM level for each zone is calculated then the the highest PWM value is selected. When in manual control mode, the Current PWM duty registers (30h-32h) become Read/Write. It is then possible to control the PWM outputs with software by writing to these registers. When the fan is disabled (100) the corresponding PWM output should be driven low (or high, if inverted). Zone 1: External Diode 1 (processor) Zone 2: Internal Sensor Zone 3: External Diode 2 TABLE 4. Fan Zone Setting ZON[2:0] Fan Configuration 000 Fan on zone 1 auto 001 Fan on zone 2 auto 010 Fan on zone 3 auto 011 Fan always on full 100 Fan disabled 101 Fan controlled by hottest of zones 2, 3 110 Fan controlled by hottest of zones 1, 2, 3 111 Fan manually controlled (Test Mode) Bit [4] PWM Invert Bit [4] inverts the PWM output. If set to 0, 100% duty cycle will yield an output that is always high. If set to 1, 100% duty cycle will yield an output that is always low. Bit [3] Reserved Bits [2:0] Spin Up Bits [2:0] specify the ‘spin up’ time for the fan. When a fan is being started from a stationary state, the PWM output is held at 100% duty cycle for the time specified in the table below before scaling to a lower speed. www.national.com 18 LM96000 Functional Description (Continued) TABLE 5. Fan Spin-Up Register SPIN[2:0] Spin Up Time 000 0 sec 001 100 ms 010 250 ms 011 400 ms 100 700 ms 101 1000 ms 110 2000 ms 111 4000 ms 4.15 Registers 5F-61h: Auto Fan Speed Range, PWM Frequency Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 5Fh R/W Zone1 Range/Fan1 Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U 60h R/W Zone2 Range/Fan2 Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U 61h R/W Zone3 Range/Fan3 Frequency RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h U In Auto Fan Mode, when the temperature for a zone is above the Temperature Limit (Registers 67-69h) and below its Absolute Temperature Limit (Registers 6A-6Ch), the speed of a fan assigned to that zone is determined as follows. When the temperature reaches the Fan Temp Limit for a zone, the PWM output assigned to that zone will be Fan PWM Minimum. Between Fan Temp Limit and (Fan Temp Limit + Range), the PWM duty cycle will increase linearly according to the temperature as shown in the figure below. The PWM duty cycle will be 100% at (Fan Temp Limit + Range). 20084606 FIGURE 1. Fan Activity above Fan Temp Limit Example for PWM1 assigned to Zone 1: – Zone 1 Fan Temp Limit (Register 67h) is set to 50˚C (32h). – Range (Register 5Fh) is set to 8˚C (6xh). – Fan 1 PWM Minimum (Register 64h) is set to 50% (32h). In this case, the PWM1 duty cycle will be 50% at 50˚C. Since (Zone 1 Fan Temp Limit) + (Zone 1 Range) = 50˚C + 8˚C = 58˚C, the fan will run at 100% duty cycle when the temperature of the Zone 1 sensor reaches 58˚C. Since the midpoint of the fan control range is 54˚C, and the median duty cycle is 75% (Halfway between the PWM Minimum and 100%), PWM1 duty cycle would be 75% at 54˚C. 19 www.national.com LM96000 Functional Description (Continued) Above (Zone 1 Fan Temp Limit) + (Zone 1 Range), the duty cycle will be 100%. PWM frequency bits [3:0] The PWM frequency bits [3:0] determine the PWM frequency for the fan.The LM96000 has high and low frequency ranges for the PWM outputs, that are controlled by the HLFRQ bit. PWM Frequency Selection (Default = 0011 = 30.04 Hz). TABLE 6. Register Setting vs PWM Frequency HLFRQ Freq [2:0] PWM Frequency 0 000 10.01 Hz 0 001 15.02 Hz 0 010 23.14 Hz 0 011 30.04 Hz 0 100 38.16 Hz 0 101 47.06 Hz 0 110 61.38 Hz 0 111 94.12 Hz 1 000 22.5 kHz 1 001 24 kHz 1 010 25.7 kHz 1 011 25.7 kHz 1 100 27.7 kHz 1 101 27.7 kHz 1 110 30 kHz 1 111 30 kHz Range Selection RAN [3:0] RAN [3:0] Range (˚C) 0000 2 0001 2.5 0010 3.33 0011 4 0100 5 0101 6.67 0110 8 0111 10 1000 13.33 1001 16 1010 20 1011 26.67 1100 32 1101 40 1110 53.33 1111 80 This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. 4.16 Registers 62, 63h: Min/Off, Spike Smoothing Register Read/ Register Address Write Name 62h R/W www.national.com Bit 7 Bit 6 (MSB) Min/Off, Zone1 Spike Smoothing OFF3 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lock? (LSB) Value OFF2 OFF1 RES ZN1E ZN1-2 ZN1-1 ZN1-0 00h 20 U (Continued) Register Read/ Register Address Write Name Bit 7 Bit 6 (MSB) 63h ZN2E R/W Zone2, Zone3 Spike Smoothing Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lock? (LSB) Value ZN2-2 ZN2-1 ZN2-0 ZN3E ZN3-2 ZN3-1 ZN3-0 00h U The Off/Min Bits [7:5] specify whether the duty cycle will be 0% or Minimum Fan Duty when the measured temperature falls below the Temperature LIMIT register setting (see table below). OFF1 applies to fan 1, OFF2 applies to fan 2, and OFF3 applies to fan 3. If the Remote1 or Remote2 pins are connected to a processor or chipset, instantaneous temperature spikes may be sampled by the LM96000. If these spikes are not ignored, the CPU fan (if connected to LM96000) may turn on prematurely and produce unpleasant noise. For this reason, any zone that is connected to a chipset or processor should have spike smoothing enabled. When spike smoothing is enabled, the temperature reading registers will still reflect the current value of the temperature — not the ‘smoothed out’ value. ZN1E, ZN2E, and ZN3E enable temperature smoothing for zones 1, 2, and 3 respectively. ZN1-2, ZN1-1, and ZN1-0 control smoothing time for Zone 1. ZN2-2, ZN2-1, and ZN2-0 control smoothing time for Zone 2. ZN3-2, ZN3-1, and ZN3-0 control smoothing time for Zone 3. These registers become ready only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to these registers shall have no effect. 20084607 FIGURE 2. What LM96000 Auto Fan Control Sees With and Without Spike Smoothing TABLE 7. Spike Smoothing ZN-X[2:0] Spike Smoothed Over 000 35 seconds 001 17.6 seconds 010 11.8 seconds 011 7.0 seconds 100 4.4 seconds 101 3.0 seconds 110 1.6 seconds 111 .8 seconds TABLE 8. PWM Output Below Limit Depending on Value of Off/Min Off/Min PWM Action 0 At 0% duty below LIMIT 1 At Min PWM Duty below LIMIT 21 www.national.com LM96000 Functional Description LM96000 Functional Description (Continued) 4.17 Registers 64-66h: Minimum PWM Duty Cycle Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 64h R/W Fan1 PWM Minimum 7 6 5 4 3 2 1 0 80h U 65h R/W Fan2 PWM Minimum 7 6 5 4 3 2 1 0 80h U 66h R/W Fan3 PWM Minimum 7 6 5 4 3 2 1 0 80h U These registers specify the minimum duty cycle that the PWM will output when the measured temperature reaches the Temperature LIMIT register setting. This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. TABLE 9. PWM Duty vs Register Setting for PWM Low Frequency Range Current Duty Value (Decimal) Value (Hex) 0% 0 00h 0.3922% 1 01h . . . . . . . . . 25.098% 64 40h . . . . . . . . . 50.196% 128 80h . . . . . . . . . 100% 255 FF PWM Duty Cycle vs Register Setting for PWM High Frequency Range 22.5KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal 24KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal Value in Hex Value in Hex 0.00 0 0 0 0 0 6.25 1 - 15 01 - 0F 6.67 1 - 16 01 - 10 12.50 16 - 31 10 - 1F 13.33 17 - 33 11 - 21 18.75 32 - 47 20 - 2F 20.00 34 - 50 22 - 32 25.00 48 - 63 30 - 3F 26.67 51 - 67 33 - 43 31.25 64 - 79 40 - 4F 33.33 68 - 84 44 - 54 37.50 80 - 95 50 - 5F 40.00 85 - 101 55 - 65 43.75 96 - 111 60 - 6F 46.67 102 - 118 66 - 76 50.00 112 - 127 70 - 7F 53.33 119 - 136 77 - 88 56.25 128 - 143 80 - 8F 60.00 137 - 153 89 - 99 62.50 144 - 159 90 - 9F 66.67 154 - 170 9A - AA 68.75 160 - 175 A0 - AF 73.33 171 - 187 AB - BB 75.00 176 - 191 B0 - BF 80.00 188 - 204 BC - CC 81.25 192 - 207 C0 - CF 86.67 205 - 221 CD - DD 87.50 208 - 223 D0 - DF 93.33 222 - 238 DE - EE 93.75 224 - 239 E0 - EF 100.00 239 - 255 EF - FF 100.00 240 - 255 F0 - FF www.national.com 22 (Continued) 27.7KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal 25.7KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal Value in Hex 0 0 0 7.14 1 - 17 01 - 11 14.29 18 - 36 12 - 24 21.43 37 - 54 25 - 36 28.57 55 - 72 37 - 48 35.71 73 - 90 49 - 5A 42.86 91 - 109 5B - 6D 50.00 110 - 127 6E - 7F 57.14 128 - 145 80 - 91 64.29 146 - 164 92 - A4 71.43 165 - 182 98 - 117 62 - 75 53.85 118 - 137 76 - 89 61.54 138 - 157 8A - 9D 69.23 158 - 176 9E - B0 76.92 177 - 196 B1 - C4 84.62 197 - 216 C5 - D8 92.31 217 - 235 D9 - EB 100.00 236 - 255 EC - FF 30KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal 183 - 200 B7 - C8 85.71 201 - 218 C9 - DA 92.86 219 - 237 DB - ED 100.00 238 - 255 EE - FF 27.7KHz PWM Frequency PWM Duty Cycle Level (%) Value in Decimal Value in Hex 0 0 0 7.69 1 - 19 01 - 13 15.38 20 - 38 14 - 26 23.08 39 - 58 27 - 3A 30.77 59 - 78 3B - 4E 38.46 79 - 97 4F - 61 Value in Hex 0 0 0 8.33 1 - 20 01 - 14 16.67 21 - 42 15 - 2A 25.00 43 - 63 2B - 3F 33.33 64 - 84 40 - 54 41.67 85 - 106 55 - 6A 50.00 107 - 127 6B - 7F 58.33 128 - 148 80 - 94 66.67 149 - 170 95 - AA 75.00 171 - 191 AB - BF 83.33 192 - 212 C0 - D4 91.67 213 - 234 D5 - EA 100.00 235 - 255 EB - FF A5 - B6 78.57 Value in Hex 46.15 4.18 Registers 67-69h: Temperature Limit Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 67h R/W Zone1 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U 68h R/W Zone2 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U 69h R/W Zone3 Fan Temp Limit 7 6 5 4 3 2 1 0 5Ah U These are the temperature limits for the individual zones. When the current temperature equals this limit, the fan will be turned on if it is not already. When the temperature exceeds this limit, the fan speed will be increased according to the algorithm set forth in the Auto Fan Range, PWM Frequency register description. Default = 90˚C = 5Ah This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. TABLE 10. Temperature Limit vs Register Setting Temperature Reading (Decimal) Reading (Hex) −127˚C −127 81h . . . . . . . . . −50˚C −50 CEh . . . . . . . . . 23 www.national.com LM96000 Functional Description LM96000 Functional Description (Continued) TABLE 10. Temperature Limit vs Register Setting (Continued) Temperature Reading (Decimal) Reading (Hex) 0˚C 0 00h . . . . . . . . . 50˚C 50 32h . . . . . . . . . 127˚C 127 7Fh 4.19 Registers 6A-6Ch: Absolute Temperature Limit Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 6Ah R/W Zone1 Absolute Temp Limit 7 6 5 4 3 2 1 0 64h U 6Bh R/W Zone2 Absolute Temp Limit 7 6 5 4 3 2 1 0 64h U 6Ch R/W Zone3 Absolute Temp Limit 7 6 5 4 3 2 1 0 64h U In the Auto Fan mode, if a zone exceeds the temperature set in the Absolute Temperature Limit register, all of the PWM outputs will incresase its duty cycle to 100%. This is a safety feature that attempts to cool the system if there is a potentially catastrophic thermal event. If set to 80h (-128˚C), the feature is disabled. Default=100˚C=64h These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to these registers shall have no effect. After power up the default values are used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to these registers are possible. TABLE 11. Absolute Limit vs Register Setting Temperature Reading (Decimal) Reading (Hex) −127˚C −127 81h . . . . . . . . . −50˚C −50 CEh . . . . . . . . . 0˚C 0 00h . . . . . . . . . 50˚C 50 32h . . . . . . . . . 127˚C 127 7Fh 4.20 Registers 6D-6Eh: Zone Hysteresis Registers Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value Lock? 6Dh R/W Zone1 and Zone2 Hysteresis H1-3 H1-2 H1-1 H1-0 H2-3 H2-2 H2-1 H2-0 44h U 6Eh R/W Zone3 Hysteresis H3-3 H3-2 H3-1 H3-0 RES RES RES RES 40h U If the temperature is above Fan Temp Limit, then drops below Fan Temp Limit, the following will occur: www.national.com 24 (Continued) – The fan will remain on, at Fan PWM Minimum, until the temperature goes a certain amount below Fan Temp Limit. – The Hysteresis registers control this amount. See below table for details. These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to thses registers shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. TABLE 12. Hysteresis Settings Setting HYSTERESIS 0h 0˚C . . . . . . 5h 5˚C . . . . . . Fh 15˚C 4.21 Register 6Fh: Test Register Register Address Read/ Write Register Name Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value 6Fh R/W Test Register RES RES RES RES RES RES RES XEN 00h If the XEN bit is set high, the part will be placed into XOR tree test mode. Clearing the bit (writing a 0 to the XEN bit) brings the part out of XOR tree test mode. This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this registers shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. 4.22 Registers 70-7Fh: Vendor Specific Registers These registers are for vendor specific features, including test registers. They will not default to a specific value on power up. 4.22.1 Register 74h: Tachometer Monitor Mode Register Address Read/ Write 74h R/W Register Name Tach Monitor Mode Bit 7 (MSb) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSb) Default Value RES RES T3/4-1 T3/4-0 T2-1 T2-0 T1-1 T1-0 00h Lock? Each fan TACH input has 4 possible modes of operation when using the low frequency range for the PWM outputs. Mode 0 is the only mode that is available when using the high frequecy range for the PWM outputs. The modes for TACH3 and TACH4 share control bits T3/4-[1:0]; TACH2 is controlled by T2-[1:0]; TACH1 is controlled by T1-[1:0]. The result reported in all modes is based on 2 pulses per revolution. In order for modes 2 and 3 to function properly it is required that the: PWM1 output must control the fan that has it’s tachometer output connected to the TACH1 LM96000 input. PWM2 output must control the fan that has it’s tachometer output connected to the TACH2 LM96000 input. PWM3 output must control the fans that have their tachometer outputs connected to the TACH3 or TACH4 LM96000 inputs. Setting (Tn[1:0]) Mode Function 00 0 Traditional tach input monitor, false readings when under minimum detctable RPM 01 1 Traditional tach input monitor, FFFFh reading when under minimum detectable RPM 10 2 Most accurate readings, FFFFh reading when under minimum detectable RPM 11 3 Least effect on programmed PWM of Fan, FFFFh reading when under minimum detectable RPM • Mode 0: This mode uses the conventional method for fan tachometer pulse detection and does not include any circuitry to compensate for PWM Fan drive. This mode should be used when PWM drive is not used to power the fan. This mode may report a false RPM reading when under minimum detectable RPM as shown in the following table. • Mode 1: This mode uses the conventional method for fan tach detection. The reading will be FFFFh if it is below minimum detectable RPM. 25 www.national.com LM96000 Functional Description LM96000 Functional Description (Continued) • Mode 2: This mode is optimized for accurate RPM readings and activates circuitry that extends the lower side of the RPM reading as shown in the following table. • Mode 3: This mode minimizes the effect on the RPM setting and activates circuitry that extends the lower side of the RPM reading as shown in the following table. PWM Frequency Mode 0 and 1 Minimum RPM 10.01 841 Mode 2 and 3 Minimum RPM 210 15.02 1262 315 23.14 1944 420 30.04 2523 420 38.16 3205 420 47.06 3953 420 61.38 5156 420 94.12 7906 420 This register is not effected when the Ready/Lock/Start/Override register Lock bit is set. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. 4.22.2 Register 75h: Fan Spin-up Mode Register Read/ Address Write 75h R/W Register Name Fan Spin-up Mode Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 (MSB) RES RES RES RES Bit 2 Bit 1 Bit 0 (LSB) RES PWM3 SU PWM2 SU PWM1 SU Default Lock? Value 7h U The PWM SU bit configures the PWM spin-up mode. If PWM SU is cleared the spin-up time will terminate after time programmed by the Fan Configuration register has elapsed. When set to a 1, the spin-up time will terminate early if the TACH reading exceeds the Tach Minimum value or after the time programmed by the Fan Configuration register has elapsed, whichever occurs first. This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible. 4.23 Undefined Registers Any reads to undefined registers will always return 00h. Writes to undefined registers will have no effect and will not return an error. 5.0 XOR TEST MODE The LM96000 incorporates a XOR tree test mode. When the test mode is enabled by setting the “XEN” bit high in the Test Register at address 6Fh via the SMBus, the part will enter XOR test mode. Since the test mode an XOR tree, the order of the signals in the tree is not important. SMBDAT and SMBCLK are not to be included in the test tree. 20084608 www.national.com 26 LM96000 Applications Information 20084609 Typical Applications Schematic 27 www.national.com LM96000 Hardware Monitor with Integrated Fan Control Physical Dimensions inches (millimeters) unless otherwise noted 24-Lead Molded TSSOP Package, Order Number LM96000CIMT or LM96000CIMTX NS Package Number MTC24E JEDEC Registration MO-153, Variation AD National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. For the most current product information visit us at www.national.com. LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. BANNED SUBSTANCE COMPLIANCE National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2. National Semiconductor Americas Customer Support Center Email: [email protected] Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Customer Support Center Fax: +49 (0) 180-530 85 86 Email: [email protected] Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 National Semiconductor Asia Pacific Customer Support Center Email: [email protected] National Semiconductor Japan Customer Support Center Fax: 81-3-5639-7507 Email: [email protected] Tel: 81-3-5639-7560