HT48R30A-1/HT48C30-1 I/O Type 8-Bit MCU Technical Document · Tools Information · FAQs · Application Note - HA0003E Communicating between the HT48 & HT46 Series MCUs and the HT93LC46 EEPROM HA0004E HT48 & HT46 MCU UART Software Implementation Method HA0013E HT48 & HT46 LCM Interface Design HA0021E Using the I/O Ports on the HT48 MCU Series HA0055E 2^12 Decoder (8+4 - Corresponds to HT12E) Features · Operating voltage: · 96´8 data memory RAM fSYS=4MHz: 2.2V~5.5V fSYS=8MHz: 3.3V~5.5V · Buzzer driving pair and PFD supported · HALT function and wake-up feature reduce power · Low voltage reset function consumption · 25 bidirectional I/O lines (max.) · 4-level subroutine nesting · 1 interrupt input shared with an I/O line · Up to 0.5ms instruction cycle with 8MHz system clock · 8-bit programmable timer/event counter with overflow at VDD=5V interrupt and 8-stage prescaler · Bit manipulation instruction · On-chip RC oscillator, external crystal and RC oscil- · 14-bit table read instruction lator · 63 powerful instructions · 32768Hz crystal oscillator for timing purposes only · All instructions in one or two machine cycles · Watchdog Timer · 24/28-pin SKDIP/SOP package · 2048´14 program memory ROM General Description The HT48R30A-1/HT48C30-1 are 8-bit high performance, RISC architecture microcontroller devices specifically designed for multiple I/O control product applications. The mask version HT48C30-1 is fully pin and functionally compatible with the OTP version HT48R30A-1 device. Rev. 2.00 The advantages of low power consumption, I/O flexibility, timer functions, oscillator options, HALT and wake-up functions, watchdog timer, buzzer driver, as well as low cost, enhance the versatility of these devices to suit a wide range of application possibilities such as industrial control, consumer products, subsystem controllers, etc. 1 April 24, 2009 HT48R30A-1/HT48C30-1 Block Diagram IN T /P G 0 In te rru p t C ir c u it P ro g ra m R O M S T A C K 4 L e v e ls P ro g ra m C o u n te r T M R C M T M R IN T C P G 0 In s tr u c tio n R e g is te r M M P U T M R /P C 0 X fS E N /D IS W D T S U D A T A M e m o ry X M P r e s c a le r M W D T W D T P r e s c a le r U Y S U fS Y S X /4 R T C X O S C W D T O S C P A C M U X In s tr u c tio n D e c o d e r P B C P G 1 P G 2 S h ifte r O S P R V V C 1 / G 1 E S D D S S P O R T B P B 0 ~ P B 7 P B P C C O S C 2 / P G 2 P A 0 ~ P A 7 B Z /B Z S T A T U S A L U T im in g G e n e ra to r P O R T A P A P O R T C P C 0 ~ P C 5 P C A C C In te rn a l R C O S C P G C P O R T G P G 0 ~ P G 2 P G Pin Assignment 1 2 8 P B 6 P B 4 2 2 7 P B 7 P B 5 1 2 4 P B 6 P A 3 3 2 6 P A 4 P B 4 2 2 3 P B 7 P A 2 4 2 5 P A 5 P A 3 3 2 2 P A 4 P A 1 5 2 4 P A 6 P A 2 4 2 1 P A 5 P A 0 6 2 3 P A 7 P A 1 5 2 0 P A 6 P B 3 7 2 2 O S C 2 /P G 2 P A 0 6 1 9 P A 7 P B 2 8 2 1 O S C 1 /P G 1 P B 3 7 1 8 O S C 2 /P G 2 P B 1 /B Z 9 2 0 V D D P B 2 8 1 7 O S C 1 /P G 1 P B 0 /B Z 1 0 1 9 R E S P B 1 /B Z 9 1 6 V D D V S S 1 1 1 8 P C 5 P B 0 /B Z 1 0 1 5 R E S P G 0 /IN T 1 2 1 7 P C 4 V S S 1 1 1 4 P C 2 P C 0 /T M R 1 3 1 6 P C 3 P G 0 /IN T 1 2 1 3 P C 0 /T M R P C 1 1 4 1 5 P C 2 H T 4 8 R 3 0 A -1 /H T 4 8 C 3 0 -1 2 4 S K D IP -A /S O P -A Rev. 2.00 P B 5 H T 4 8 R 3 0 A -1 /H T 4 8 C 3 0 -1 2 8 S K D IP -A /S O P -A 2 April 24, 2009 HT48R30A-1/HT48C30-1 Pin Description Pin Name I/O Options Description PA0~PA7 I/O Pull-high* Wake-up CMOS/Schmitt trigger Input Bidirectional 8-bit input/output port. Each bit can be configured as a wake-up input by options. Software instructions determine the CMOS output or Schmitt trigger or CMOS input (depends on an options) with pull-high resistor (determined by 1-bit pull-high options). Bidirectional 8-bit input/output port. Software instructions determine the CMOS output or Schmitt trigger input with pull-high resistor (determined by pull-high options). The PB0 and PB1 are pin-shared with the BZ and BZ, respectively. Once the PB0 or PB1 is selected as buzzer driving outputs, the output signals come from an internal PFD generator (shared with timer/event counter). PB0/BZ PB1/BZ PB2~PB7 I/O Pull-high* PB0 or BZ PB1 or BZ VSS ¾ ¾ Negative power supply, ground PG0/INT I/O Pull-high* Bidirectional I/O lines. Software instructions determine the CMOS output or Schmitt trigger input with pull-high resistor (determined by 1-bit pull-high options). This external interrupt input is pin-shared with PG0. The external interrupt input is activated on a high to low transition. PC0/TMR PC1~PC5 I/O Pull-high* Bidirectional I/O lines. Software instructions determine the CMOS output or Schmitt trigger input with pull-high resistor (determined by 1-bit pull-high options). The timer input are pin-shared with PC0. RES I ¾ Schmitt trigger reset input. Active low VDD ¾ ¾ Positive power supply Pull-high* OSC1/PG1 OSC2/PG2 Note: I O Crystal or RC or Int. RC+I/O or Int. RC+RTC OSC1, OSC2 are connected to an RC network or Crystal (determined by options) for the internal system clock. In the case of RC operation, OSC2 is the output terminal for 1/4 system clock. These two pins can also be optioned as an RTC oscillator (32768Hz) or I/O lines. In these two cases, the system clock comes from an internal RC oscillator whose frequency has 4 options (3.2MHz, 1.6MHz, 800kHz, 400kHz). If the I/O option is selected, the pull-high options can also be enabled or disabled. Otherwise the PG1 and PG2 are used as internal registers (pull-high resistors are always disabled). ²*² The pull-high resistors of each I/O port (PA, PB, PC, PG) are controlled by 1-bit option. Or Schmitt trigger option of port A is controlled by 1-bit option. Absolute Maximum Ratings Supply Voltage ...........................VSS-0.3V to VSS+6.0V Storage Temperature ............................-50°C to 125°C Input Voltage..............................VSS-0.3V to VDD+0.3V Operating Temperature...........................-40°C to 85°C Note: These are stress ratings only. Stresses exceeding the range specified under ²Absolute Maximum Ratings² may cause substantial damage to the device. Functional operation of this device at other conditions beyond those listed in the specification is not implied and prolonged exposure to extreme conditions may affect device reliability. Rev. 2.00 3 April 24, 2009 HT48R30A-1/HT48C30-1 D.C. Characteristics Symbol VDD IDD1 Parameter Operating Voltage Ta=25°C Test Conditions VDD Conditions ¾ 5.5 V ¾ fSYS=8MHz 3.3 ¾ 5.5 V ¾ 0.6 1.5 mA ¾ 2 4 mA ¾ 0.8 1.5 mA 5V ¾ 2.5 4 mA 5V No load, fSYS=8MHz ¾ 4 8 mA 3V ¾ ¾ 5 mA ¾ ¾ 10 mA ¾ ¾ 1 mA ¾ ¾ 2 mA ¾ ¾ 5 mA ¾ ¾ 10 mA 3V Operating Current (RC OSC) ISTB1 Standby Current (WDT Enabled RTC Off) No load, fSYS=4MHz No load, fSYS=4MHz No load, system HALT 5V ISTB2 3V Standby Current (WDT Disabled RTC Off) No load, system HALT 5V ISTB3 Unit 2.2 3V Operating Current (Crystal OSC, RC OSC) Max. fSYS=4MHz Operating Current (Crystal OSC) IDD3 Typ. ¾ 5V IDD2 Min. 3V Standby Current (WDT Disabled, RTC On) No load, system HALT 5V VIL1 Input Low Voltage for I/O Ports ¾ ¾ 0 ¾ 0.3VDD V VIH1 Input High Voltage for I/O Ports ¾ ¾ 0.7VDD ¾ VDD V VIL2 Input Low Voltage (RES) ¾ ¾ 0 ¾ 0.4VDD V VIH2 Input High Voltage (RES) ¾ ¾ 0.9VDD ¾ VDD V VLVR Low Voltage Reset ¾ 2.7 3.0 3.3 V IOL 3V VOL=0.1VDD 4 8 ¾ mA I/O Port Sink Current 5V VOL=0.1VDD 10 20 ¾ mA 3V VOH=0.9VDD -2 -4 ¾ mA 5V VOH=0.9VDD -5 -10 ¾ mA 3V ¾ 20 60 100 kW 5V ¾ 10 30 50 kW IOH RPH Rev. 2.00 I/O Port Source Current LVR enabled Pull-high Resistance 4 April 24, 2009 HT48R30A-1/HT48C30-1 A.C. Characteristics Symbol fSYS1 fSYS2 fSYS3 fTIMER Ta=25°C Parameter System Clock (Crystal OSC) System Clock (RC OSC) System Clock (Internal RC OSC) Timer I/P Frequency (TMR) tWDTOSC Watchdog Oscillator Period Test Conditions VDD Conditions Min. Typ. Max. Unit ¾ 2.2V~5.5V 400 ¾ 4000 kHz ¾ 3.3V~5.5V 400 ¾ 8000 kHz ¾ 2.2V~5.5V 400 ¾ 4000 kHz ¾ 3.3V~5.5V 400 ¾ 8000 kHz 3.2MHz 1800 ¾ 5400 kHz 1.6MHz 900 ¾ 2700 kHz 800kHz 450 ¾ 1350 kHz 400kHz 225 ¾ 675 kHz 5V ¾ 2.2V~5.5V 0 ¾ 4000 kHz ¾ 3.3V~5.5V 0 ¾ 8000 kHz 3V ¾ 45 90 180 ms 5V ¾ 32 65 130 ms 11 23 46 ms 8 17 33 ms 3V tWDT1 Watchdog Time-out Period (WDT OSC) tWDT2 Watchdog Time-out Period (System Clock) ¾ Without WDT prescaler ¾ 1024 ¾ tSYS tWDT3 Watchdog Time-out Period (RTC OSC) ¾ Without WDT prescaler ¾ 7.812 ¾ ms tRES External Reset Low Pulse Width ¾ ¾ 1 ¾ ¾ ms tSST System Start-up Timer Period ¾ ¾ 1024 ¾ tSYS tINT Interrupt Pulse Width ¾ 1 ¾ ¾ ms Rev. 2.00 Without WDT prescaler 5V 5 Wake-up from HALT ¾ April 24, 2009 HT48R30A-1/HT48C30-1 Functional Description Execution Flow incremented by one. The program counter then points to the memory word containing the next instruction code. The system clock for the microcontroller is derived from either a crystal or an RC oscillator. The system clock is internally divided into four non-overlapping clocks. One instruction cycle consists of four system clock cycles. When executing a jump instruction, conditional skip execution, loading PCL register, subroutine call or return from subroutine, initial reset, internal interrupt, external interrupt or return from interrupt, the PC manipulates the program transfer by loading the address corresponding to each instruction. Instruction fetching and execution are pipelined in such a way that a fetch takes an instruction cycle while decoding and execution takes the next instruction cycle. However, the pipelining scheme causes each instruction to effectively execute in a cycle. If an instruction changes the program counter, two cycles are required to complete the instruction. The conditional skip is activated by instructions. Once the condition is met, the next instruction, fetched during the current instruction execution, is discarded and a dummy cycle replaces it to get the proper instruction. Otherwise proceed with the next instruction. Program Counter - PC The lower byte of the program counter (PCL) is a readable and writeable register (06H). Moving data into the PCL performs a short jump. The destination will be within the current program ROM page. The program counter (PC) controls the sequence in which the instructions stored in the program ROM are executed and its contents specify a full range of program memory. When a control transfer takes place, an additional dummy cycle is required. After accessing a program memory word to fetch an instruction code, the contents of the program counter are S y s te m O S C 2 (R C C lo c k T 1 T 2 T 3 T 4 T 1 T 2 T 3 T 4 T 1 T 2 T 3 T 4 o n ly ) P C P C P C + 1 F e tc h IN S T (P C ) E x e c u te IN S T (P C -1 ) P C + 2 F e tc h IN S T (P C + 1 ) E x e c u te IN S T (P C ) F e tc h IN S T (P C + 2 ) E x e c u te IN S T (P C + 1 ) Execution Flow Program Counter Mode *10 *9 *8 *7 *6 *5 *4 *3 *2 *1 *0 Initial Reset 0 0 0 0 0 0 0 0 0 0 0 External Interrupt 0 0 0 0 0 0 0 0 1 0 0 Timer/Event Counter Overflow 0 0 0 0 0 0 0 1 0 0 0 @3 @2 @1 @0 Skip Program Counter+2 Loading PCL *10 *9 *8 @7 @6 @5 @4 Jump, Call Branch #10 #9 #8 #7 #6 #5 #4 #3 #2 #1 #0 Return from Subroutine S10 S9 S8 S7 S6 S5 S4 S3 S2 S1 S0 Program Counter Note: *10~*0: Program counter bits S10~S0: Stack register bits #10~#0: Instruction code bits Rev. 2.00 @7~@0: PCL bits 6 April 24, 2009 HT48R30A-1/HT48C30-1 · Table location Program Memory - ROM Any location in the program memory space can be used as look-up tables. The instructions ²TABRDC [m]² (the current page, one page=256 words) and ²TABRDL [m]² (the last page) transfer the contents of the lower-order byte to the specified data memory, and the higher-order byte to TBLH (08H). Only the destination of the lower-order byte in the table is well-defined, the other bits of the table word are transferred to the lower portion of TBLH, and the remaining 2-bits words are read as ²0². The Table Higher-order byte register (TBLH) is read only. The table pointer (TBLP) is a read/write register (07H), which indicates the table location. Before accessing the table, the location must be placed in the TBLP. The TBLH is read only and cannot be restored. If the main routine and the ISR (Interrupt Service Routine) both employ the table read instruction, the contents of the TBLH in the main routine are likely to be changed by the table read instruction used in the ISR. Errors can occur. In other words, using the table read instruction in the main routine and the ISR simultaneously should be avoided. However, if the table read instruction has to be applied in both the main routine and the ISR, the interrupt is supposed to be disabled prior to the table read instruction. It will not be enabled until the TBLH has been backed up. All table related instructions require two cycles to complete the operation. These areas may function as normal program memory depending upon the requirements. The program memory is used to store the program instructions which are to be executed. It also contains data, table, and interrupt entries, and is organized into 2048´14 bits, addressed by the program counter and table pointer. Certain locations in the program memory are reserved for special usage: · Location 000H This area is reserved for program initialization. After chip reset, the program always begins execution at location 000H. · Location 004H This area is reserved for the external interrupt service program. If the INT input pin is activated, the interrupt is enabled and the stack is not full, the program begins execution at location 004H. · Location 008H This area is reserved for the timer/event counter interrupt service program. If a timer interrupt results from a timer/event counter overflow, and if the interrupt is enabled and the stack is not full, the program begins execution at location 008H . 0 0 0 H D e v ic e In itia liz a tio n P r o g r a m 0 0 4 H E x te r n a l In te r r u p t S u b r o u tin e 0 0 8 H T im e r /E v e n t C o u n te r In te r r u p t S u b r o u tin e Stack Register - STACK This is a special part of the memory which is used to save the contents of the Program Counter only. The stack is organized into 4 levels and is neither part of the data nor part of the program space, and is neither readable nor writeable. The activated level is indexed by the stack pointer (SP) and is neither readable nor writeable. At a subroutine call or interrupt acknowledge signal, the contents of the program counter are pushed onto the stack. At the end of a subroutine or an interrupt routine, signaled by a return instruction (RET or RETI), the program counter is restored to its previous value from the stack. After a chip reset, the SP will point to the top of the stack. P ro g ra m M e m o ry n 0 0 H L o o k - u p T a b le ( 2 5 6 w o r d s ) n F F H 7 0 0 H L o o k - u p T a b le ( 2 5 6 w o r d s ) 7 F F H 1 4 b its N o te : n ra n g e s fro m 0 to 7 Program Memory Instruction Table Location *10 *9 *8 *7 *6 *5 *4 *3 *2 *1 *0 TABRDC [m] P10 P9 P8 @7 @6 @5 @4 @3 @2 @1 @0 TABRDL [m] 1 1 1 @7 @6 @5 @4 @3 @2 @1 @0 Table Location Note: *10~*0: Table location bits P10~P8: Current program counter bits @7~@0: Table pointer bits Rev. 2.00 7 April 24, 2009 HT48R30A-1/HT48C30-1 If the stack is full and a non-masked interrupt takes place, the interrupt request flag will be recorded but the acknowledge signal will be inhibited. When the stack pointer is (by RET or RETI), the interrupt will be serviced. This feature prevents stack overflow allowing the programmer to use the structure more easily. In a similar case, if the stack is full and a ²CALL² is subsequently executed, stack overflow occurs and the first entry will be lost (only the most recent 4 return addresses are stored). 0 0 H In d ir e c t A d d r e s s in g R e g is te r 0 1 H M P 0 2 H 0 3 H 0 4 H 0 5 H Data Memory - RAM A C C 0 6 H P C L 0 7 H T B L P 0 8 H T B L H 0 9 H W D T S 0 A H S T A T U S 0 B H IN T C 0 C H The data memory is designed with 115´8 bits. The data memory is divided into two functional groups: special function registers and general purpose data memory (96´8). Most are read/write, but some are read only. 0 D H T M R 0 E H T M R C S p e c ia l P u r p o s e D A T A M E M O R Y 0 F H 1 0 H The special function registers include the indirect addressing registers (R0;00H), timer/event counter (TMR;0DH), timer/event counter control register (TMRC;0EH), program counter lower-order byte register (PCL;06H), memory pointer registers (MP;01H), accumulator (ACC;05H), table pointer (TBLP;07H), table higher-order byte register (TBLH;08H), status register (STATUS;0AH), interrupt control register (INTC;0BH), Watchdog Timer option setting register (WDTS;09H), I/O registers (PA;12H, PB;14H, PC;16H, PG;1EH) and I/O control registers (PAC;13H, PBC;15H, PCC;17H, PGC;1FH). The remaining space before the 20H is reserved for future expanded usage and reading these locations will get ²00H². The general purpose data memory, addressed from 20H to 7FH, is used for data and control information under instruction commands. 1 1 H 1 2 H P A 1 3 H P A C 1 4 H P B 1 5 H P B C 1 6 H P C 1 7 H P C C 1 8 H 1 9 H : U n u s e d 1 A H 1 B H R e a d a s "0 0 " 1 C H 1 D H All of the data memory areas can handle arithmetic, logic, increment, decrement and rotate operations directly. Except for some dedicated bits, each bit in the data memory can be set and reset by ²SET [m].i² and ²CLR [m].i². They are also indirectly accessible through memory pointer registers (MP). 1 E H P G 1 F H 2 0 H P G C 7 F H G e n e ra l P u rp o s e D A T A M E M O R Y (9 6 B y te s ) RAM Mapping Arithmetic and logic unit - ALU This circuit performs 8-bit arithmetic and logic operations. The ALU provides the following functions: Indirect Addressing Register Location 00H is indirect addressing register that is not physically implemented. Any read/write operation of [00H] will access data memory pointed to by MP. Reading location 00H itself indirectly will return the result 00H. Writing indirectly results in no operation. · Arithmetic operations (ADD, ADC, SUB, SBC, DAA) · Logic operations (AND, OR, XOR, CPL) · Rotation (RL, RR, RLC, RRC) · Increment and Decrement (INC, DEC) The memory pointer register (MP) is 7-bit registers. · Branch decision (SZ, SNZ, SIZ, SDZ ....) Accumulator The ALU not only saves the results of a data operation but also changes the status register. The accumulator is closely related to ALU operations. It is also mapped to location 05H of the data memory and can carry out immediate data operations. The data movement between two data memory locations must pass through the accumulator. Rev. 2.00 8 April 24, 2009 HT48R30A-1/HT48C30-1 Status Register - STATUS rupt requires servicing within the service routine, the EMI bit and the corresponding bit of the INTC may be set to allow interrupt nesting. If the stack is full, the interrupt request will not be acknowledged, even if the related interrupt is enabled, until the SP is decremented. If immediate service is desired, the stack must be prevented from becoming full. This 8-bit register (0AH) contains the zero flag (Z), carry flag (C), auxiliary carry flag (AC), overflow flag (OV), power down flag (PDF), and watchdog time-out flag (TO). It also records the status information and controls the operation sequence. With the exception of the TO and PDF flags, bits in the status register can be altered by instructions like most other registers. Any data written into the status register will not change the TO or PDF flag. In addition operations related to the status register may give different results from those intended. The TO flag can be affected only by system power-up, a WDT time-out or executing the ²CLR WDT² or ²HALT² instruction. The PDF flag can be affected only by executing the ²HALT² or ²CLR WDT² instruction or during a system power-up. All these kinds of interrupts have a wake-up capability. As an interrupt is serviced, a control transfer occurs by pushing the program counter onto the stack, followed by a branch to a subroutine at specified location in the program memory. Only the program counter is pushed onto the stack. If the contents of the register or status register (STATUS) are altered by the interrupt service program which corrupts the desired control sequence, the contents should be saved in advance. External interrupts are triggered by a high to low transition of the INT and the related interrupt request flag (EIF; bit 4 of INTC) will be set. When the interrupt is enabled, the stack is not full and the external interrupt is active, a subroutine call to location 04H will occur. The interrupt request flag (EIF) and EMI bits will be cleared to disable other interrupts. The Z, OV, AC and C flags generally reflect the status of the latest operations. In addition, on entering the interrupt sequence or executing the subroutine call, the status register will not be pushed onto the stack automatically. If the contents of the status are important and if the subroutine can corrupt the status register, precautions must be taken to save it properly. The internal timer/event counter interrupt is initialized by setting the timer/event counter interrupt request flag (TF; bit 5 of INTC), caused by a timer overflow. When the interrupt is enabled, the stack is not full and the TF bit is set, a subroutine call to location 08H will occur. The related interrupt request flag (TF) will be reset and the EMI bit cleared to disable further interrupts. Interrupt The device provides an external interrupt and internal timer/event counter interrupts. The Interrupt Control Register (INTC;0BH) contains the interrupt control bits to set the enable or disable and the interrupt request flags. During the execution of an interrupt subroutine, other interrupt acknowledge signals are held until the ²RETI² instruction is executed or the EMI bit and the related interrupt control bit are set to 1 (if the stack is not full). To return from the interrupt subroutine, ²RET² or ²RETI² may be invoked. RETI will set the EMI bit to enable an interrupt service, but RET will not. Once an interrupt subroutine is serviced, all the other interrupts will be blocked (by clearing the EMI bit). This scheme may prevent any further interrupt nesting. Other interrupt requests may occur during this interval but only the interrupt request flag is recorded. If a certain interBit No. Label Function 0 C C is set if the operation results in a carry during an addition operation or if a borrow does not take place during a subtraction operation; otherwise C is cleared. C is also affected by a rotate through carry instruction. 1 AC AC is set if the operation results in a carry out of the low nibbles in addition or no borrow from the high nibble into the low nibble in subtraction; otherwise AC is cleared. 2 Z Z is set if the result of an arithmetic or logic operation is zero; otherwise Z is cleared. 3 OV OV is set if the operation results in a carry into the highest-order bit but not a carry out of the highest-order bit, or vice versa; otherwise OV is cleared. 4 PDF PDF is cleared by system power-up or executing the ²CLR WDT² instruction. PDF is set by executing the ²HALT² instruction. 5 TO TO is cleared by system power-up or executing the ²CLR WDT² or ²HALT² instruction. TO is set by a WDT time-out. 6 ¾ Unused bit, read as ²0² 7 ¾ Unused bit, read as ²0² Status (0AH) Register Rev. 2.00 9 April 24, 2009 HT48R30A-1/HT48C30-1 Bit No. Label Function 0 EMI Controls the master (global) interrupt (1= enabled; 0= disabled) 1 EEI Controls the external interrupt (1= enabled; 0= disabled) 2 ETI Controls the Timer/Event Counter 0 interrupt (1= enabled; 0= disabled) 3 ¾ Unused bit, read as ²0² 4 EIF External interrupt request flag (1= active; 0= inactive) 5 TF Internal Timer/Event Counter 0 request flag (1= active; 0= inactive) 6 ¾ Unused bit, read as ²0² 7 ¾ Unused bit, read as ²0² INTC (0BH) Register All of them are designed for system clocks, namely the external RC oscillator, the external Crystal oscillator and the internal RC oscillator, which are determined by options. No matter what oscillator type is selected, the signal provides the system clock. The HALT mode stops the system oscillator and ignores an external signal to conserve power. Interrupts, occurring in the interval between the rising edges of two consecutive T2 pulses, will be serviced on the latter of the two T2 pulses, if the corresponding interrupts are enabled. In the case of simultaneous requests the following table shows the priority that is applied. These can be masked by resetting the EMI bit. No. Interrupt Source Priority Vector a External Interrupt 1 04H b Timer/Event Counter Overflow 2 08H If an RC oscillator is used, an external resistor between OSC1 and VDD is required and the resistance must range from 24kW to 1MW. The system clock, divided by 4, is available on OSC2, which can be used to synchronize external logic. The RC oscillator provides the most cost effective solution. However, the frequency of oscillation may vary with VDD, temperatures and the chip itself due to process variations. It is, therefore, not suitable for timing sensitive operations where an accurate oscillator frequency is desired. The timer/event counter interrupt request flag (TF), external interrupt request flag (EIF), enable timer/event counter interrupt bit (ETI), enable external interrupt bit (EEI) and enable master interrupt bit (EMI) constitute an interrupt control register (INTC) which is located at 0BH in the data memory. EMI, EEI, ETI are used to control the enabling/disabling of interrupts. These bits prevent the requested interrupt from being serviced. Once the interrupt request flags (TF, EIF) are set, they will remain in the INTC register until the interrupts are serviced or cleared by a software instruction. If the Crystal oscillator is used, a crystal across OSC1 and OSC2 is needed to provide the feedback and phase shift required for the oscillator. No other external components are required. In stead of a crystal, a resonator can also be connected between OSC1 and OSC2 to get a frequency reference, but two external capacitors in OSC1 and OSC2 are required. If the internal RC oscillator is used, the OSC1 and OSC2 can be selected as general I/O lines or an 32768Hz crystal oscillator (RTC OSC). Also, the frequencies of the internal RC oscillator can be 3.2MHz, 1.6MHz, 800kHz and 400kHz (depends on the options). It is recommended that a program does not use the ²CALL subroutine² within the interrupt subroutine. Interrupts often occur in an unpredictable manner or need to be serviced immediately in some applications. If only one stack is left and enabling the interrupt is not well controlled, the original control sequence will be damaged once the ²CALL² operates in the interrupt subroutine. The WDT oscillator is a free running on-chip RC oscillator, and no external components are required. Even if the system enters the power down mode, the system clock is stopped, but the oscillator still works within a period of 65ms at 5V. The WDT oscillator can be disabled by options to conserve power. Oscillator Configuration There are 3 oscillator circuits in the microcontroller. V O S C 1 D D O S C 1 4 7 0 p F O S C 2 C r y s ta l O s c illa to r ( In c lu d e 3 2 7 6 8 H z ) fS Y S /4 N M O S O p e n D r a in O S C 2 R C O s c illa to r System Oscillator Rev. 2.00 10 April 24, 2009 HT48R30A-1/HT48C30-1 Watchdog Timer - WDT The WDT overflow under normal operation will initialize ²chip reset² and set the status bit ²TO². But in the HALT mode, the overflow will initialize a ²warm reset² and only the Program Counter and SP are reset to zero. To clear the contents of WDT (including the WDT prescaler), three methods are adopted; external reset (a low level to RES), software instruction and a ²HALT² instruction. The software instruction include ²CLR WDT² and the other set - ²CLR WDT1² and ²CLR WDT2². Of these two types of instruction, only one can be active depending on the option - ²CLR WDT times selection option². If the ²CLR WDT² is selected (i.e. CLRWDT times equal one), any execution of the ²CLR WDT² instruction will clear the WDT. In the case that ²CLR WDT1² and ²CLR WDT2² are chosen (i.e. CLRWDT times equal two), these two instructions must be executed to clear the WDT; otherwise, the WDT may reset the chip as a result of time-out. The WDT clock source is implemented by a dedicated RC oscillator (WDT oscillator), RTC clock or instruction clock (system clock divided by 4), determines the options. This timer is designed to prevent a software malfunction or sequence from jumping to an unknown location with unpredictable results. The Watchdog Timer can be disabled by options. If the Watchdog Timer is disabled, all the executions related to the WDT result in no operation. The RTC clock is enabled only in the internal RC+RTC mode. Once the internal WDT oscillator (RC oscillator with a period of 65ms at 5V normally) is selected, it is first divided by 256 (8-stage) to get the nominal time-out period of 17ms at 5V. This time-out period may vary with temperatures, VDD and process variations. By invoking the WDT prescaler, longer time-out periods can be realized. Writing data to WS2, WS1, WS0 (bit 2,1,0 of the WDTS) can give different time-out periods. If WS2, WS1, and WS0 are all equal to 1, the division ratio is up to 1:128, and the maximum time-out period is 2.1s at 5V seconds. If the WDT oscillator is disabled, the WDT clock may still come from the instruction clock and operates in the same manner except that in the HALT state the WDT may stop counting and lose its protecting purpose. In this situation the logic can only be restarted by external logic. The high nibble and bit 3 of the WDTS are reserved for user’s defined flags, which can be used to indicate some specified status. Power Down Operation - HALT The HALT mode is initialized by the ²HALT² instruction and results in the following... · The system oscillator will be turned off but the WDT oscillator remains running (if the WDT oscillator is selected). · The contents of the on chip RAM and registers remain unchanged. · WDT and WDT prescaler will be cleared and recounted again (if the WDT clock is from the WDT oscillator). · All of the I/O ports maintain their original status. If the device operates in a noisy environment, using the on-chip RC oscillator (WDT OSC) or 32kHz crystal oscillator (RTC OSC) is strongly recommended, since the HALT will stop the system clock. WS2 WS1 WS0 Division Ratio 0 0 0 1:1 0 0 1 1:2 0 1 0 1:4 0 1 1 1:8 1 0 0 1:16 1 0 1 1:32 1 1 0 1:64 1 1 1 1:128 · The PDF flag is set and the TO flag is cleared. The system can leave the HALT mode by means of an external reset, an interrupt, an external falling edge signal on port A or a WDT overflow. An external reset causes a device initialization and the WDT overflow performs a ²warm reset². After the TO and PDF flags are examined, the reason for chip reset can be determined. The PDF flag is cleared by system power-up or executing the ²CLR WDT² instruction and is set when executing the ²HALT² instruction. The TO flag is set if the WDT time-out occurs, and causes a wake-up that only resets the Program Counter and SP; the others remain in their original status. WDTS (09H) Register S y s te m R T C C lo c k /4 O S C W D T P r e s c a le r O p tio n S e le c t 8 - b it C o u n te r W D T O S C 7 - b it C o u n te r 8 -to -1 M U X W S 0 ~ W S 2 W D T T im e - o u t Watchdog Timer Rev. 2.00 11 April 24, 2009 HT48R30A-1/HT48C30-1 The port A wake-up and interrupt methods can be considered as a continuation of normal execution. Each bit in port A can be independently selected to wake up the device by options. Awakening from an I/O port stimulus, the program will resume execution of the next instruction. If it awakens from an interrupt, two sequence may occur. If the related interrupt is disabled or the interrupt is enabled but the stack is full, the program will resume execution at the next instruction. If the interrupt is enabled and the stack is not full, the regular interrupt response takes place. If an interrupt request flag is set to ²1² before entering the HALT mode, the wake-up function of the related interrupt will be disabled. Once a wake-up event occurs, it takes 1024 (system clock period) to resume normal operation. In other words, a dummy period will be inserted after a wake-up. If the wake-up results from an interrupt acknowledge signal, the actual interrupt subroutine execution will be delayed by one or more cycles. If the wake-up results in the next instruction execution, this will be executed immediately after the dummy period is finished. V D D R E S tS S T S S T T im e - o u t C h ip R e s e t Reset Timing Chart V D D 0 .0 1 m F * 1 0 0 k W R E S 1 0 k W 0 .1 m F * Reset Circuit Note: To minimize power consumption, all the I/O pins should be carefully managed before entering the HALT status. The RTC oscillator still runs in the HALT mode (if the RTC oscillator is enabled). H A L T Reset R E S ²*² Make the length of the wiring, which is connected to the RES pin as short as possible, to avoid noise interference. W a rm R e s e t W D T C o ld R e s e t There are three ways in which a reset can occur: · RES reset during normal operation O S C 1 · RES reset during HALT S S T 1 0 - b it R ip p le C o u n te r · WDT time-out reset during normal operation S y s te m The time-out during HALT is different from other chip reset conditions, since it can perform a ²warm reset² that resets only the Program Counter and SP, leaving the other circuits in their original state. Some registers remain unchanged during other reset conditions. Most registers are reset to the ²initial condition² when the reset conditions are met. By examining the PDF and TO flags, the program can distinguish between different ²chip resets². TO PDF Reset Configuration When a system reset occurs, the SST delay is added during the reset period. Any wake-up from HALT will enable the SST delay. An extra option load time delay is added during system reset (power-up, WDT time-out at normal mode or RES reset). RESET Conditions 0 0 RES reset during power-up u u RES reset during normal operation 0 1 RES wake-up HALT 1 u WDT time-out during normal operation 1 1 WDT wake-up HALT The functional unit chip reset status are shown below. Note: ²u² stands for ²unchanged² To guarantee that the system oscillator is started and stabilized, the SST (System Start-up Timer) provides an extra-delay of 1024 system clock pulses when the system reset (power-up, WDT time-out or RES reset) or the system awakes from the HALT state. Rev. 2.00 R e s e t 12 Program Counter 000H Interrupt Disable Prescaler Clear WDT Clear. After master reset, WDT begins counting Timer/Event Counter Off Input/Output Ports Input mode Stack Pointer Points to the top of the stack April 24, 2009 HT48R30A-1/HT48C30-1 The states of the registers is summarized in the table. Register Reset (Power On) WDT Time-out RES Reset (Normal Operation) (Normal Operation) RES Reset (HALT) WDT Time-out (HALT)* TMR xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx uuuu uuuu TMRC 00-0 1000 00-0 1000 00-0 1000 00-0 1000 uu-u uuuu 000H 000H 000H 000H 000H Program Counter MP -xxx xxxx -uuu uuuu -uuu uuuu -uuu uuuu -uuu uuuu ACC xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLP xxxx xxxx uuuu uuuu uuuu uuuu uuuu uuuu uuuu uuuu TBLH --xx xxxx --uu uuuu --uu uuuu --uu uuuu --uu uuuu STATUS --00 xxxx --1u uuuu --uu uuuu --01 uuuu --11 uuuu INTC --00 -000 --00 -000 --00 -000 --00 -000 --uu -uuu WDTS 0000 0111 0000 0111 0000 0111 0000 0111 uuuu uuuu PA 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PAC 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PB 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PBC 1111 1111 1111 1111 1111 1111 1111 1111 uuuu uuuu PC --11 1111 --11 1111 --11 1111 --11 1111 --uu uuuu PCC --11 1111 --11 1111 --11 1111 --11 1111 --uu uuuu PG ---- -111 ---- -111 ---- -111 ---- -111 ---- -uuu PGC ---- -111 ---- -111 ---- -111 ---- -111 ---- -uuu Note: ²*² stands for ²warm reset² ²u² stands for ²unchanged² ²x² stands for ²unknown² Timer/Event Counter The TM0, TM1 bits define the operating mode. The event count mode is used to count external events, which means the clock source comes from an external (TMR) pin. The timer mode functions as a normal timer with the clock source coming from the fINT clock or RTC clock. The pulse width measurement mode can be used to count the high or low level duration of the external signal. The counting is based on the fINT clock or RTC clock. Timer/event counters (TMR) is implemented in the microcontroller. The timer/event counter contains an 8-bit programmable count-up counter and the clock may come from an external source or from the system clock or RTC. Using the internal clock sources, there are 2 reference time-bases for timer/event counter. The internal clock source can be selected as coming from fSYS (can always be optioned) or fRTC (enabled only system oscillator in the Int. RC+RTC mode) by options. Using external clock input allows the user to count external events, measure time internals or pulse widths, or generate an accurate time base. While using the internal clock allows the user to generate an accurate time base. In the event count or timer mode, once the timer/event counter starts counting, it will count from the current contents in the timer/event counter to FFH. Once overflow occurs, the counter is reloaded from the timer/event counter preload register and generates the interrupt request flag (TF; bit 5 of INTC) at the same time. The timer/event counter can generate PFD signal by using external or internal clock and PFD frequency is determine by the equation fINT/[2´(256-N)]. In the pulse width measurement mode with the TON and TE bits equal to one, once the low to high (or high to low if the TE bits is ²0²) it will start counting until the TMR returns to the original level and resets the TON. The measured result will remain in the timer/event counter even if the activated transient occurs again. In other words, only one cycle measurement can be done. Until setting the TON, the cycle measurement will function again as long as it receives further transient pulse. Note that, in There are 2 registers related to the timer/event counter; TMR ([0DH]), TMRC ([0EH]). Two physical registers are mapped to TMR location; writing TMR makes the starting value be placed in the timer/event counter preload register and reading TMR gets the contents of the timer/event counter. The TMRC is a timer/event counter control register, which defines some options. Rev. 2.00 13 April 24, 2009 HT48R30A-1/HT48C30-1 data to the timer/event counter preload register will also reload that data to the timer/event counter. But if the timer/event counter is turned on, data written to it will only be kept in the timer/event counter preload register. The timer/event counter will still operate until overflow occurs (a timer/event counter reloading will occur at the same time). When the timer/event counter (reading TMR) is read, the clock will be blocked to avoid errors. As clock blocking may results in a counting error, this must be taken into consideration by the programmer. this operating mode, the timer/event counter starts counting not according to the logic level but according to the transient edges. In the case of counter overflows, the counter is reloaded from the timer/event counter preload register and issues the interrupt request just like the other two modes. To enable the counting operation, the timer ON bit (TON; bit 4 of TMRC) should be set to 1. In the pulse width measurement mode, the TON will be cleared automatically after the measurement cycle is completed. But in the other two modes the TON can only be reset by instructions. The overflow of the timer/event counter is one of the wake-up sources. No matter what the operation mode is, writing a 0 to ETI can disable the corresponding interrupt services. The bit0~bit2 of the TMRC can be used to define the pre-scaling stages of the internal clock sources of timer/event counter. The definitions are as shown. The overflow signal of timer/event counter can be used to generate PFD signals for buzzer driving. In the case of timer/event counter OFF condition, writing Bit No. Label Function To define the prescaler stages, PSC2, PSC1, PSC0= 000: fINT=fSYS/2 or fRTC/2 001: fINT=fSYS/4 or fRTC/4 010: fINT=fSYS/8 or fRTC/8 PSC0~PSC2 011: fINT=fSYS/16 or fRTC/16 100: fINT=fSYS/32 or fRTC/32 101: fINT=fSYS/64 or fRTC/64 110: fINT=fSYS/128 or fRTC/128 111: fINT=fSYS/256 or fRTC/256 0~2 3 TE 4 TON 5 ¾ 6 7 TM0 TM1 To define the TMR active edge of timer/event counter 0 (0=active on low to high; 1=active on high to low) To enable or disable timer 0 counting (0=disabled; 1=enabled) Unused bit, read as ²0² To define the operating mode 01=Event count mode (external clock) 10=Timer mode (internal clock) 11=Pulse width measurement mode 00=Unused TMRC (0EH) Register fS Y S fR T C M (1 /2 ~ 1 /2 5 6 ) U X 8 - s ta g e P r e s c a le r f IN 8 -1 M U X D a ta B u s T T M 1 T M 0 M a s k O p tio n P S C 2 ~ P S C 0 T M R T im e r /E v e n t C o u n te r P r e lo a d R e g is te r R e lo a d T E T M 1 T M 0 T O N P u ls e W id th M e a s u re m e n t M o d e C o n tro l T im e r /E v e n t C o u n te r 1 /2 O v e r flo w to In te rru p t B Z B Z Timer/Event Counter Rev. 2.00 14 April 24, 2009 HT48R30A-1/HT48C30-1 tions). Each bit of these input/output latches can be set or cleared by ²SET [m].i² and ²CLR [m].i² (m=12H, 14H, 16H or 1EH) instructions. Input/Output Ports There are 25 bidirectional input/output lines in the microcontroller, labeled from PA to PC and PG, which are mapped to the data memory of [12H], [14H], [16H] and [1EH] respectively. All of these I/O ports can be used for input and output operations. For input operation, these ports are non-latching, that is, the inputs must be ready at the T2 rising edge of instruction ²MOV A,[m]² (m=12H, 14H, 16H or 1EH). For output operation, all the data is latched and remains unchanged until the output latch is rewritten. Some instructions first input data and then follow the output operations. For example, ²SET [m].i², ²CLR [m].i², ²CPL [m]², ²CPLA [m]² read the entire port states into the CPU, execute the defined operations (bit-operation), and then write the results back to the latches or the accumulator. Each line of port A has the capability of waking-up the device. The highest 5-bit of port G are not physically implemented; on reading them a ²0² is returned whereas writing then results in no-operation. See Application note. Each I/O line has its own control register (PAC, PBC, PCC, PGC) to control the input/output configuration. With this control register, CMOS output or Schmitt trigger input with or without pull-high resistor structures can be reconfigured dynamically (i.e. on-the-fly) under software control. To function as an input, the corresponding latch of the control register must write ²1². The input source also depends on the control register. If the control register bit is ²1², the input will read the pad state. If the control register bit is ²0², the contents of the latches will move to the internal bus. The latter is possible in the ²read-modify-write² instruction. There is a pull-high option available for all I/O lines (bit option). Once the pull-high option of an I/O line is selected, the I/O line have pull-high resistor. Otherwise, the pull-high resistor is absent. It should be noted that a non-pull-high I/O line operating in input mode will cause a floating state. The PB0 and PB1 are pin-shared with BZ and BZ signal, respectively. If the BZ/BZ option is selected, the output signal in output mode of PB0/PB1 will be the PFD signal generated by timer/event counter 0 overflow signal. The input mode always remain in its original functions. Once the BZ/BZ option is selected, the buzzer output signals are controlled by the PB0 data register only. The I/O functions of PB0/PB1 are shown below. For output function, CMOS is the only configuration. These control registers are mapped to locations 13H, 15H, 17H and 1FH. After a chip reset, these input/output lines remain at high levels or floating state (depending on the pull-high opPB0 I/O I I O O O O O O O O PB1 I/O I O I I I O O O O O PB0 Mode x x C B B C B B B B PB1 Mode x C x x x C C C B B PB0 Data x x D 0 1 D0 0 1 0 1 PB1 Data x D x x x D1 D D x x PB0 Pad Status I I D 0 B D0 0 B 0 B PB1 Pad Status I D I I I D1 D D 0 B Note: ²I² input, ²O² output, ²D, D0, D1² data, ²B² buzzer option, BZ or BZ, ²x² don’t care ²C² CMOS output Rev. 2.00 15 April 24, 2009 HT48R30A-1/HT48C30-1 P G 1 /P G 2 I/O C o n tr o l B it D a ta B u s P U Q C K S C h ip R e s e t R e a d C o n tr o l R e g is te r P A 0 P B 0 P C 0 P G 0 D a ta B it Q D ~ P A ~ P B ~ P C ~ P G 7 7 5 2 Q C K W r ite D a ta R e g is te r S ( P B 0 , P B 1 O n ly ) D D Q D W r ite C o n tr o l R e g is te r V M o d e O n ly P B 0 B Z /B Z M M R e a d D a ta R e g is te r S y s te m W a k e -u p ( P A o n ly ) U U X B Z E N ( P B 0 , P B 1 O n ly ) X O P 0 ~ O P 7 IN T fo r P G 0 O n ly Input/Output Ports does not exceed 1ms, the LVR will ignore it and do not perform a reset function. The PG0 is pin-shared with INT. In case of ²Internal RC+I/O² system oscillator, the PG1 and PG2 are pin-shared with OSC1 and OSC2 pins. Once the ²Internal RC+I/O² mode is selected, the PG1 and PG2 can be used as general purpose I/O lines. Otherwise, the pull-high resistors and I/O functions of PG1 and PG2 will be disabled. · The LVR uses the ²OR² function with the external RES signal to perform chip reset. The relationship between VDD and VLVR is shown below. V D D 5 .5 V It is recommended that unused or not bonded out I/O lines should be set as output pins by software instruction to avoid consuming power under input floating state. V O P R 5 .5 V V Low Voltage Reset - LVR L V R 3 .0 V The microcontroller provides low voltage reset circuit in order to monitor the supply voltage of the device. If the supply voltage of the device is within the range 0.9V~VLVR, such as changing a battery, the LVR will automatically reset the device internally. 2 .2 V 0 .9 V Note: The LVR includes the following specifications: · The low voltage (0.9V~VLVR) has to remain in their VOPR is the voltage range for proper chip operation at 4MHz system clock. original state to exceed 1ms. If the low voltage state Rev. 2.00 16 April 24, 2009 HT48R30A-1/HT48C30-1 V D D 5 .5 V V L V R L V R D e te c t V o lta g e 0 .9 V 0 V R e s e t S ig n a l R e s e t N o r m a l O p e r a tio n R e s e t *1 *2 Low Voltage Reset Note: *1: To make sure that the system oscillator has stabilized, the SST provides an extra delay of 1024 system clock pulses before entering the normal operation. *2: Since low voltage has to be maintained in its original state and exceed 1ms, therefore 1ms delay enters the reset mode. Options The following table shows all kinds of options in the microcontroller. All of the options must be defined to ensure proper system functioning. Items Options 1 WDT clock source: WDT oscillator or fSYS/4 or RTC oscillator or disable 2 CLRWDT instructions: 1 or 2 instructions 3 Timer/event counter clock sources: fSYS or RTCOSC 4 PA bit wake-up enable or disable 5 PA CMOS or Schmitt input 6 PA, PB, PC, PG pull-high enable or disable (By port) 7 BZ/BZ enable or disable 8 LVR enable or disable 9 System oscillator Ext. RC, Ext.crystal, Int.RC+RTC or Int.RC+PG1/PG2 10 Int.RC frequency selection 3.2MHz, 1.6MHz, 800kHz or 400kHz Rev. 2.00 17 April 24, 2009 HT48R30A-1/HT48C30-1 Application Circuits V D D R O S C O S C 1 4 7 0 p F V O S C 2 N M O S o p e n d r a in D D C 1 0 .0 1 m F * V D D 1 0 0 k W R E S O S C 1 P A 0 ~ P A 7 C 2 P B 2 ~ P B 7 0 .1 m F P C 1 ~ P C 5 O S C 2 R 1 C ry s ta l S y s te m F o r th e v a lu e s , s e e ta b le b e lo w O s c illa to r 1 0 k W 0 .1 m F * V S S O S C 1 P B 0 /B Z P B 1 /B Z O S C C ir c u it O S C 2 In te r n a l R C O s c illa to r O S C 1 a n d O S C 2 le ft u n c o n n e c te d O S C 1 O S C 2 P C 0 /T M R O S C 1 S e e R ig h t S id e 1 0 p F 3 2 7 6 8 H z P G 0 /IN T In te r n a l R C w ith R T C O s c illa to r O S C 2 H T 4 8 R 3 0 A -1 /H T 4 8 C 3 0 -1 Note: R C S y s te m O s c illa to r 2 4 k W < R O S C < 1 M W O S C C ir c u it The resistance and capacitance for reset circuit should be designed to ensure that the VDD is stable and remains in a valid range of the operating voltage before bringing RES to high. ²*² Make the length of the wiring, which is connected to the RES pin as short as possible, to avoid noise interference. The following table shows the C1, C2 and R1 values corresponding to the different crystal values. (For reference only) Crystal or Resonator C1, C2 R1 4MHz Crystal 0pF 10kW 4MHz Resonator 10pF 12kW 3.58MHz Crystal 0pF 10kW 3.58MHz Resonator 25pF 10kW 2MHz Crystal & Resonator 25pF 10kW 1MHz Crystal 35pF 27kW 480kHz Resonator 300pF 9.1kW 455kHz Resonator 300pF 10kW 429kHz Resonator 300pF 10kW The function of the resistor R1 is to ensure that the oscillator will switch off should low voltage conditions occur. Such a low voltage, as mentioned here, is one which is less than the lowest value of the MCU operating voltage. Note however that if the LVR is enabled then R1 can be removed. Rev. 2.00 18 April 24, 2009 HT48R30A-1/HT48C30-1 Instruction Set subtract instruction mnemonics to enable the necessary arithmetic to be carried out. Care must be taken to ensure correct handling of carry and borrow data when results exceed 255 for addition and less than 0 for subtraction. The increment and decrement instructions INC, INCA, DEC and DECA provide a simple means of increasing or decreasing by a value of one of the values in the destination specified. Introduction C e n t ra l t o t he s uc c es s f ul oper a t i on o f a n y microcontroller is its instruction set, which is a set of program instruction codes that directs the microcontroller to perform certain operations. In the case of Holtek microcontrollers, a comprehensive and flexible set of over 60 instructions is provided to enable programmers to implement their application with the minimum of programming overheads. Logical and Rotate Operations For easier understanding of the various instruction codes, they have been subdivided into several functional groupings. The standard logical operations such as AND, OR, XOR and CPL all have their own instruction within the Holtek microcontroller instruction set. As with the case of most instructions involving data manipulation, data must pass through the Accumulator which may involve additional programming steps. In all logical data operations, the zero flag may be set if the result of the operation is zero. Another form of logical data manipulation comes from the rotate instructions such as RR, RL, RRC and RLC which provide a simple means of rotating one bit right or left. Different rotate instructions exist depending on program requirements. Rotate instructions are useful for serial port programming applications where data can be rotated from an internal register into the Carry bit from where it can be examined and the necessary serial bit set high or low. Another application where rotate data operations are used is to implement multiplication and division calculations. Instruction Timing Most instructions are implemented within one instruction cycle. The exceptions to this are branch, call, or table read instructions where two instruction cycles are required. One instruction cycle is equal to 4 system clock cycles, therefore in the case of an 8MHz system oscillator, most instructions would be implemented within 0.5ms and branch or call instructions would be implemented within 1ms. Although instructions which require one more cycle to implement are generally limited to the JMP, CALL, RET, RETI and table read instructions, it is important to realize that any other instructions which involve manipulation of the Program Counter Low register or PCL will also take one more cycle to implement. As instructions which change the contents of the PCL will imply a direct jump to that new address, one more cycle will be required. Examples of such instructions would be ²CLR PCL² or ²MOV PCL, A². For the case of skip instructions, it must be noted that if the result of the comparison involves a skip operation then this will also take one more cycle, if no skip is involved then only one cycle is required. Branches and Control Transfer Program branching takes the form of either jumps to specified locations using the JMP instruction or to a subroutine using the CALL instruction. They differ in the sense that in the case of a subroutine call, the program must return to the instruction immediately when the subroutine has been carried out. This is done by placing a return instruction RET in the subroutine which will cause the program to jump back to the address right after the CALL instruction. In the case of a JMP instruction, the program simply jumps to the desired location. There is no requirement to jump back to the original jumping off point as in the case of the CALL instruction. One special and extremely useful set of branch instructions are the conditional branches. Here a decision is first made regarding the condition of a certain data memory or individual bits. Depending upon the conditions, the program will continue with the next instruction or skip over it and jump to the following instruction. These instructions are the key to decision making and branching within the program perhaps determined by the condition of certain input switches or by the condition of internal data bits. Moving and Transferring Data The transfer of data within the microcontroller program is one of the most frequently used operations. Making use of three kinds of MOV instructions, data can be transferred from registers to the Accumulator and vice-versa as well as being able to move specific immediate data directly into the Accumulator. One of the most important data transfer applications is to receive data from the input ports and transfer data to the output ports. Arithmetic Operations The ability to perform certain arithmetic operations and data manipulation is a necessary feature of most microcontroller applications. Within the Holtek microcontroller instruction set are a range of add and Rev. 2.00 19 April 24, 2009 HT48R30A-1/HT48C30-1 Bit Operations Other Operations The ability to provide single bit operations on Data Memory is an extremely flexible feature of all Holtek microcontrollers. This feature is especially useful for output port bit programming where individual bits or port pins can be directly set high or low using either the ²SET [m].i² or ²CLR [m].i² instructions respectively. The feature removes the need for programmers to first read the 8-bit output port, manipulate the input data to ensure that other bits are not changed and then output the port with the correct new data. This read-modify-write process is taken care of automatically when these bit operation instructions are used. In addition to the above functional instructions, a range of other instructions also exist such as the ²HALT² instruction for Power-down operations and instructions to control the operation of the Watchdog Timer for reliable program operations under extreme electric or electromagnetic environments. For their relevant operations, refer to the functional related sections. Instruction Set Summary The following table depicts a summary of the instruction set categorised according to function and can be consulted as a basic instruction reference using the following listed conventions. Table Read Operations Table conventions: Data storage is normally implemented by using registers. However, when working with large amounts of fixed data, the volume involved often makes it inconvenient to store the fixed data in the Data Memory. To overcome this problem, Holtek microcontrollers allow an area of Program Memory to be setup as a table where data can be directly stored. A set of easy to use instructions provides the means by which this fixed data can be referenced and retrieved from the Program Memory. Mnemonic x: Bits immediate data m: Data Memory address A: Accumulator i: 0~7 number of bits addr: Program memory address Description Cycles Flag Affected 1 1Note 1 1 1Note 1 1 1Note 1 1Note 1Note Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV Z, C, AC, OV C 1 1 1 1Note 1Note 1Note 1 1 1 1Note 1 Z Z Z Z Z Z Z Z Z Z Z 1 1Note 1 1Note Z Z Z Z Arithmetic ADD A,[m] ADDM A,[m] ADD A,x ADC A,[m] ADCM A,[m] SUB A,x SUB A,[m] SUBM A,[m] SBC A,[m] SBCM A,[m] DAA [m] Add Data Memory to ACC Add ACC to Data Memory Add immediate data to ACC Add Data Memory to ACC with Carry Add ACC to Data memory with Carry Subtract immediate data from the ACC Subtract Data Memory from ACC Subtract Data Memory from ACC with result in Data Memory Subtract Data Memory from ACC with Carry Subtract Data Memory from ACC with Carry, result in Data Memory Decimal adjust ACC for Addition with result in Data Memory Logic Operation AND A,[m] OR A,[m] XOR A,[m] ANDM A,[m] ORM A,[m] XORM A,[m] AND A,x OR A,x XOR A,x CPL [m] CPLA [m] Logical AND Data Memory to ACC Logical OR Data Memory to ACC Logical XOR Data Memory to ACC Logical AND ACC to Data Memory Logical OR ACC to Data Memory Logical XOR ACC to Data Memory Logical AND immediate Data to ACC Logical OR immediate Data to ACC Logical XOR immediate Data to ACC Complement Data Memory Complement Data Memory with result in ACC Increment & Decrement INCA [m] INC [m] DECA [m] DEC [m] Rev. 2.00 Increment Data Memory with result in ACC Increment Data Memory Decrement Data Memory with result in ACC Decrement Data Memory 20 April 24, 2009 HT48R30A-1/HT48C30-1 Mnemonic Description Cycles Flag Affected Rotate Data Memory right with result in ACC Rotate Data Memory right Rotate Data Memory right through Carry with result in ACC Rotate Data Memory right through Carry Rotate Data Memory left with result in ACC Rotate Data Memory left Rotate Data Memory left through Carry with result in ACC Rotate Data Memory left through Carry 1 1Note 1 1Note 1 1Note 1 1Note None None C C None None C C Move Data Memory to ACC Move ACC to Data Memory Move immediate data to ACC 1 1Note 1 None None None Clear bit of Data Memory Set bit of Data Memory 1Note 1Note None None Jump unconditionally Skip if Data Memory is zero Skip if Data Memory is zero with data movement to ACC Skip if bit i of Data Memory is zero Skip if bit i of Data Memory is not zero Skip if increment Data Memory is zero Skip if decrement Data Memory is zero Skip if increment Data Memory is zero with result in ACC Skip if decrement Data Memory is zero with result in ACC Subroutine call Return from subroutine Return from subroutine and load immediate data to ACC Return from interrupt 2 1Note 1note 1Note 1Note 1Note 1Note 1Note 1Note 2 2 2 2 None None None None None None None None None None None None None Read table (current page) to TBLH and Data Memory Read table (last page) to TBLH and Data Memory 2Note 2Note None None No operation Clear Data Memory Set Data Memory Clear Watchdog Timer Pre-clear Watchdog Timer Pre-clear Watchdog Timer Swap nibbles of Data Memory Swap nibbles of Data Memory with result in ACC Enter power down mode 1 1Note 1Note 1 1 1 1Note 1 1 None None None TO, PDF TO, PDF TO, PDF None None TO, PDF Rotate RRA [m] RR [m] RRCA [m] RRC [m] RLA [m] RL [m] RLCA [m] RLC [m] Data Move MOV A,[m] MOV [m],A MOV A,x Bit Operation CLR [m].i SET [m].i Branch JMP addr SZ [m] SZA [m] SZ [m].i SNZ [m].i SIZ [m] SDZ [m] SIZA [m] SDZA [m] CALL addr RET RET A,x RETI Table Read TABRDC [m] TABRDL [m] Miscellaneous NOP CLR [m] SET [m] CLR WDT CLR WDT1 CLR WDT2 SWAP [m] SWAPA [m] HALT Note: 1. For skip instructions, if the result of the comparison involves a skip then two cycles are required, if no skip takes place only one cycle is required. 2. Any instruction which changes the contents of the PCL will also require 2 cycles for execution. 3. For the ²CLR WDT1² and ²CLR WDT2² instructions the TO and PDF flags may be affected by the execution status. The TO and PDF flags are cleared after both ²CLR WDT1² and ²CLR WDT2² instructions are consecutively executed. Otherwise the TO and PDF flags remain unchanged. Rev. 2.00 21 April 24, 2009 HT48R30A-1/HT48C30-1 Instruction Definition ADC A,[m] Add Data Memory to ACC with Carry Description The contents of the specified Data Memory, Accumulator and the carry flag are added. The result is stored in the Accumulator. Operation ACC ¬ ACC + [m] + C Affected flag(s) OV, Z, AC, C ADCM A,[m] Add ACC to Data Memory with Carry Description The contents of the specified Data Memory, Accumulator and the carry flag are added. The result is stored in the specified Data Memory. Operation [m] ¬ ACC + [m] + C Affected flag(s) OV, Z, AC, C ADD A,[m] Add Data Memory to ACC Description The contents of the specified Data Memory and the Accumulator are added. The result is stored in the Accumulator. Operation ACC ¬ ACC + [m] Affected flag(s) OV, Z, AC, C ADD A,x Add immediate data to ACC Description The contents of the Accumulator and the specified immediate data are added. The result is stored in the Accumulator. Operation ACC ¬ ACC + x Affected flag(s) OV, Z, AC, C ADDM A,[m] Add ACC to Data Memory Description The contents of the specified Data Memory and the Accumulator are added. The result is stored in the specified Data Memory. Operation [m] ¬ ACC + [m] Affected flag(s) OV, Z, AC, C AND A,[m] Logical AND Data Memory to ACC Description Data in the Accumulator and the specified Data Memory perform a bitwise logical AND operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²AND² [m] Affected flag(s) Z AND A,x Logical AND immediate data to ACC Description Data in the Accumulator and the specified immediate data perform a bitwise logical AND operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²AND² x Affected flag(s) Z ANDM A,[m] Logical AND ACC to Data Memory Description Data in the specified Data Memory and the Accumulator perform a bitwise logical AND operation. The result is stored in the Data Memory. Operation [m] ¬ ACC ²AND² [m] Affected flag(s) Z Rev. 2.00 22 April 24, 2009 HT48R30A-1/HT48C30-1 CALL addr Subroutine call Description Unconditionally calls a subroutine at the specified address. The Program Counter then increments by 1 to obtain the address of the next instruction which is then pushed onto the stack. The specified address is then loaded and the program continues execution from this new address. As this instruction requires an additional operation, it is a two cycle instruction. Operation Stack ¬ Program Counter + 1 Program Counter ¬ addr Affected flag(s) None CLR [m] Clear Data Memory Description Each bit of the specified Data Memory is cleared to 0. Operation [m] ¬ 00H Affected flag(s) None CLR [m].i Clear bit of Data Memory Description Bit i of the specified Data Memory is cleared to 0. Operation [m].i ¬ 0 Affected flag(s) None CLR WDT Clear Watchdog Timer Description The TO, PDF flags and the WDT are all cleared. Operation WDT cleared TO ¬ 0 PDF ¬ 0 Affected flag(s) TO, PDF CLR WDT1 Pre-clear Watchdog Timer Description The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT2 and must be executed alternately with CLR WDT2 to have effect. Repetitively executing this instruction without alternately executing CLR WDT2 will have no effect. Operation WDT cleared TO ¬ 0 PDF ¬ 0 Affected flag(s) TO, PDF CLR WDT2 Pre-clear Watchdog Timer Description The TO, PDF flags and the WDT are all cleared. Note that this instruction works in conjunction with CLR WDT1 and must be executed alternately with CLR WDT1 to have effect. Repetitively executing this instruction without alternately executing CLR WDT1 will have no effect. Operation WDT cleared TO ¬ 0 PDF ¬ 0 Affected flag(s) TO, PDF Rev. 2.00 23 April 24, 2009 HT48R30A-1/HT48C30-1 CPL [m] Complement Data Memory Description Each bit of the specified Data Memory is logically complemented (1¢s complement). Bits which previously contained a 1 are changed to 0 and vice versa. Operation [m] ¬ [m] Affected flag(s) Z CPLA [m] Complement Data Memory with result in ACC Description Each bit of the specified Data Memory is logically complemented (1¢s complement). Bits which previously contained a 1 are changed to 0 and vice versa. The complemented result is stored in the Accumulator and the contents of the Data Memory remain unchanged. Operation ACC ¬ [m] Affected flag(s) Z DAA [m] Decimal-Adjust ACC for addition with result in Data Memory Description Convert the contents of the Accumulator value to a BCD ( Binary Coded Decimal) value resulting from the previous addition of two BCD variables. If the low nibble is greater than 9 or if AC flag is set, then a value of 6 will be added to the low nibble. Otherwise the low nibble remains unchanged. If the high nibble is greater than 9 or if the C flag is set, then a value of 6 will be added to the high nibble. Essentially, the decimal conversion is performed by adding 00H, 06H, 60H or 66H depending on the Accumulator and flag conditions. Only the C flag may be affected by this instruction which indicates that if the original BCD sum is greater than 100, it allows multiple precision decimal addition. Operation [m] ¬ ACC + 00H or [m] ¬ ACC + 06H or [m] ¬ ACC + 60H or [m] ¬ ACC + 66H Affected flag(s) C DEC [m] Decrement Data Memory Description Data in the specified Data Memory is decremented by 1. Operation [m] ¬ [m] - 1 Affected flag(s) Z DECA [m] Decrement Data Memory with result in ACC Description Data in the specified Data Memory is decremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. Operation ACC ¬ [m] - 1 Affected flag(s) Z HALT Enter power down mode Description This instruction stops the program execution and turns off the system clock. The contents of the Data Memory and registers are retained. The WDT and prescaler are cleared. The power down flag PDF is set and the WDT time-out flag TO is cleared. Operation TO ¬ 0 PDF ¬ 1 Affected flag(s) TO, PDF Rev. 2.00 24 April 24, 2009 HT48R30A-1/HT48C30-1 INC [m] Increment Data Memory Description Data in the specified Data Memory is incremented by 1. Operation [m] ¬ [m] + 1 Affected flag(s) Z INCA [m] Increment Data Memory with result in ACC Description Data in the specified Data Memory is incremented by 1. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. Operation ACC ¬ [m] + 1 Affected flag(s) Z JMP addr Jump unconditionally Description The contents of the Program Counter are replaced with the specified address. Program execution then continues from this new address. As this requires the insertion of a dummy instruction while the new address is loaded, it is a two cycle instruction. Operation Program Counter ¬ addr Affected flag(s) None MOV A,[m] Move Data Memory to ACC Description The contents of the specified Data Memory are copied to the Accumulator. Operation ACC ¬ [m] Affected flag(s) None MOV A,x Move immediate data to ACC Description The immediate data specified is loaded into the Accumulator. Operation ACC ¬ x Affected flag(s) None MOV [m],A Move ACC to Data Memory Description The contents of the Accumulator are copied to the specified Data Memory. Operation [m] ¬ ACC Affected flag(s) None NOP No operation Description No operation is performed. Execution continues with the next instruction. Operation No operation Affected flag(s) None OR A,[m] Logical OR Data Memory to ACC Description Data in the Accumulator and the specified Data Memory perform a bitwise logical OR operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²OR² [m] Affected flag(s) Z Rev. 2.00 25 April 24, 2009 HT48R30A-1/HT48C30-1 OR A,x Logical OR immediate data to ACC Description Data in the Accumulator and the specified immediate data perform a bitwise logical OR operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²OR² x Affected flag(s) Z ORM A,[m] Logical OR ACC to Data Memory Description Data in the specified Data Memory and the Accumulator perform a bitwise logical OR operation. The result is stored in the Data Memory. Operation [m] ¬ ACC ²OR² [m] Affected flag(s) Z RET Return from subroutine Description The Program Counter is restored from the stack. Program execution continues at the restored address. Operation Program Counter ¬ Stack Affected flag(s) None RET A,x Return from subroutine and load immediate data to ACC Description The Program Counter is restored from the stack and the Accumulator loaded with the specified immediate data. Program execution continues at the restored address. Operation Program Counter ¬ Stack ACC ¬ x Affected flag(s) None RETI Return from interrupt Description The Program Counter is restored from the stack and the interrupts are re-enabled by setting the EMI bit. EMI is the master interrupt global enable bit. If an interrupt was pending when the RETI instruction is executed, the pending Interrupt routine will be processed before returning to the main program. Operation Program Counter ¬ Stack EMI ¬ 1 Affected flag(s) None RL [m] Rotate Data Memory left Description The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit 0. Operation [m].(i+1) ¬ [m].i; (i = 0~6) [m].0 ¬ [m].7 Affected flag(s) None RLA [m] Rotate Data Memory left with result in ACC Description The contents of the specified Data Memory are rotated left by 1 bit with bit 7 rotated into bit 0. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. Operation ACC.(i+1) ¬ [m].i; (i = 0~6) ACC.0 ¬ [m].7 Affected flag(s) None Rev. 2.00 26 April 24, 2009 HT48R30A-1/HT48C30-1 RLC [m] Rotate Data Memory left through Carry Description The contents of the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7 replaces the Carry bit and the original carry flag is rotated into bit 0. Operation [m].(i+1) ¬ [m].i; (i = 0~6) [m].0 ¬ C C ¬ [m].7 Affected flag(s) C RLCA [m] Rotate Data Memory left through Carry with result in ACC Description Data in the specified Data Memory and the carry flag are rotated left by 1 bit. Bit 7 replaces the Carry bit and the original carry flag is rotated into the bit 0. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. Operation ACC.(i+1) ¬ [m].i; (i = 0~6) ACC.0 ¬ C C ¬ [m].7 Affected flag(s) C RR [m] Rotate Data Memory right Description The contents of the specified Data Memory are rotated right by 1 bit with bit 0 rotated into bit 7. Operation [m].i ¬ [m].(i+1); (i = 0~6) [m].7 ¬ [m].0 Affected flag(s) None RRA [m] Rotate Data Memory right with result in ACC Description Data in the specified Data Memory and the carry flag are rotated right by 1 bit with bit 0 rotated into bit 7. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. Operation ACC.i ¬ [m].(i+1); (i = 0~6) ACC.7 ¬ [m].0 Affected flag(s) None RRC [m] Rotate Data Memory right through Carry Description The contents of the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0 replaces the Carry bit and the original carry flag is rotated into bit 7. Operation [m].i ¬ [m].(i+1); (i = 0~6) [m].7 ¬ C C ¬ [m].0 Affected flag(s) C RRCA [m] Rotate Data Memory right through Carry with result in ACC Description Data in the specified Data Memory and the carry flag are rotated right by 1 bit. Bit 0 replaces the Carry bit and the original carry flag is rotated into bit 7. The rotated result is stored in the Accumulator and the contents of the Data Memory remain unchanged. Operation ACC.i ¬ [m].(i+1); (i = 0~6) ACC.7 ¬ C C ¬ [m].0 Affected flag(s) C Rev. 2.00 27 April 24, 2009 HT48R30A-1/HT48C30-1 SBC A,[m] Subtract Data Memory from ACC with Carry Description The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. Operation ACC ¬ ACC - [m] - C Affected flag(s) OV, Z, AC, C SBCM A,[m] Subtract Data Memory from ACC with Carry and result in Data Memory Description The contents of the specified Data Memory and the complement of the carry flag are subtracted from the Accumulator. The result is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. Operation [m] ¬ ACC - [m] - C Affected flag(s) OV, Z, AC, C SDZ [m] Skip if decrement Data Memory is 0 Description The contents of the specified Data Memory are first decremented by 1. If the result is 0 the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Operation [m] ¬ [m] - 1 Skip if [m] = 0 Affected flag(s) None SDZA [m] Skip if decrement Data Memory is zero with result in ACC Description The contents of the specified Data Memory are first decremented by 1. If the result is 0, the following instruction is skipped. The result is stored in the Accumulator but the specified Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0, the program proceeds with the following instruction. Operation ACC ¬ [m] - 1 Skip if ACC = 0 Affected flag(s) None SET [m] Set Data Memory Description Each bit of the specified Data Memory is set to 1. Operation [m] ¬ FFH Affected flag(s) None SET [m].i Set bit of Data Memory Description Bit i of the specified Data Memory is set to 1. Operation [m].i ¬ 1 Affected flag(s) None Rev. 2.00 28 April 24, 2009 HT48R30A-1/HT48C30-1 SIZ [m] Skip if increment Data Memory is 0 Description The contents of the specified Data Memory are first incremented by 1. If the result is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Operation [m] ¬ [m] + 1 Skip if [m] = 0 Affected flag(s) None SIZA [m] Skip if increment Data Memory is zero with result in ACC Description The contents of the specified Data Memory are first incremented by 1. If the result is 0, the following instruction is skipped. The result is stored in the Accumulator but the specified Data Memory contents remain unchanged. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Operation ACC ¬ [m] + 1 Skip if ACC = 0 Affected flag(s) None SNZ [m].i Skip if bit i of Data Memory is not 0 Description If bit i of the specified Data Memory is not 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is 0 the program proceeds with the following instruction. Operation Skip if [m].i ¹ 0 Affected flag(s) None SUB A,[m] Subtract Data Memory from ACC Description The specified Data Memory is subtracted from the contents of the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. Operation ACC ¬ ACC - [m] Affected flag(s) OV, Z, AC, C SUBM A,[m] Subtract Data Memory from ACC with result in Data Memory Description The specified Data Memory is subtracted from the contents of the Accumulator. The result is stored in the Data Memory. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. Operation [m] ¬ ACC - [m] Affected flag(s) OV, Z, AC, C SUB A,x Subtract immediate data from ACC Description The immediate data specified by the code is subtracted from the contents of the Accumulator. The result is stored in the Accumulator. Note that if the result of subtraction is negative, the C flag will be cleared to 0, otherwise if the result is positive or zero, the C flag will be set to 1. Operation ACC ¬ ACC - x Affected flag(s) OV, Z, AC, C Rev. 2.00 29 April 24, 2009 HT48R30A-1/HT48C30-1 SWAP [m] Swap nibbles of Data Memory Description The low-order and high-order nibbles of the specified Data Memory are interchanged. Operation [m].3~[m].0 « [m].7 ~ [m].4 Affected flag(s) None SWAPA [m] Swap nibbles of Data Memory with result in ACC Description The low-order and high-order nibbles of the specified Data Memory are interchanged. The result is stored in the Accumulator. The contents of the Data Memory remain unchanged. Operation ACC.3 ~ ACC.0 ¬ [m].7 ~ [m].4 ACC.7 ~ ACC.4 ¬ [m].3 ~ [m].0 Affected flag(s) None SZ [m] Skip if Data Memory is 0 Description If the contents of the specified Data Memory is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Operation Skip if [m] = 0 Affected flag(s) None SZA [m] Skip if Data Memory is 0 with data movement to ACC Description The contents of the specified Data Memory are copied to the Accumulator. If the value is zero, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0 the program proceeds with the following instruction. Operation ACC ¬ [m] Skip if [m] = 0 Affected flag(s) None SZ [m].i Skip if bit i of Data Memory is 0 Description If bit i of the specified Data Memory is 0, the following instruction is skipped. As this requires the insertion of a dummy instruction while the next instruction is fetched, it is a two cycle instruction. If the result is not 0, the program proceeds with the following instruction. Operation Skip if [m].i = 0 Affected flag(s) None TABRDC [m] Read table (current page) to TBLH and Data Memory Description The low byte of the program code (current page) addressed by the table pointer (TBLP) is moved to the specified Data Memory and the high byte moved to TBLH. Operation [m] ¬ program code (low byte) TBLH ¬ program code (high byte) Affected flag(s) None TABRDL [m] Read table (last page) to TBLH and Data Memory Description The low byte of the program code (last page) addressed by the table pointer (TBLP) is moved to the specified Data Memory and the high byte moved to TBLH. Operation [m] ¬ program code (low byte) TBLH ¬ program code (high byte) Affected flag(s) None Rev. 2.00 30 April 24, 2009 HT48R30A-1/HT48C30-1 XOR A,[m] Logical XOR Data Memory to ACC Description Data in the Accumulator and the specified Data Memory perform a bitwise logical XOR operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²XOR² [m] Affected flag(s) Z XORM A,[m] Logical XOR ACC to Data Memory Description Data in the specified Data Memory and the Accumulator perform a bitwise logical XOR operation. The result is stored in the Data Memory. Operation [m] ¬ ACC ²XOR² [m] Affected flag(s) Z XOR A,x Logical XOR immediate data to ACC Description Data in the Accumulator and the specified immediate data perform a bitwise logical XOR operation. The result is stored in the Accumulator. Operation ACC ¬ ACC ²XOR² x Affected flag(s) Z Rev. 2.00 31 April 24, 2009 HT48R30A-1/HT48C30-1 Package Information 24-pin SKDIP (300mil) Outline Dimensions A A 1 3 2 4 B 1 3 2 4 B 1 2 1 1 2 1 H H C C D D E F I G E F I G Fig2. 1/2 Lead Packages Fig1. Full Lead Packages · MS-001d (see fig1) Symbol A Dimensions in mil Min. Nom. Max. 1230 ¾ 1280 B 240 ¾ 280 C 115 ¾ 195 D 115 ¾ 150 E 14 ¾ 22 F 45 ¾ 70 G ¾ 100 ¾ H 300 ¾ 325 I ¾ ¾ 430 · MS-001d (see fig2) Symbol Rev. 2.00 Dimensions in mil Min. Nom. Max. A 1160 ¾ 1195 B 240 ¾ 280 C 115 ¾ 195 D 115 ¾ 150 E 14 ¾ 22 F 45 ¾ 70 G ¾ 100 ¾ H 300 ¾ 325 I ¾ ¾ 430 32 April 24, 2009 HT48R30A-1/HT48C30-1 · MO-095a (see fig2) Symbol A Rev. 2.00 Dimensions in mil Min. Nom. Max. 1145 ¾ 1185 B 275 ¾ 295 C 120 ¾ 150 D 110 ¾ 150 E 14 ¾ 22 F 45 ¾ 60 G ¾ 100 ¾ H 300 ¾ 325 I ¾ ¾ 430 33 April 24, 2009 HT48R30A-1/HT48C30-1 28-pin SKDIP (300mil) Outline Dimensions A B 2 8 1 5 1 1 4 H C D E Symbol Rev. 2.00 F I G Dimensions in mil Min. Nom. Max. A 1375 ¾ 1395 B 278 ¾ 298 C 125 ¾ 135 D 125 ¾ 145 E 16 ¾ 20 F 50 ¾ 70 G ¾ 100 ¾ H 295 ¾ 315 I ¾ ¾ 375 34 April 24, 2009 HT48R30A-1/HT48C30-1 24-pin SOP (300mil) Outline Dimensions 1 3 2 4 A B 1 2 1 C C ' G H D E a F · MS-013 Symbol Rev. 2.00 Dimensions in mil Min. Nom. Max. A 393 ¾ 419 B 256 ¾ 300 C 12 ¾ 20 C¢ 598 ¾ 613 D ¾ ¾ 104 E ¾ 50 ¾ F 4 ¾ 12 G 16 ¾ 50 H 8 ¾ 13 a 0° ¾ 8° 35 April 24, 2009 HT48R30A-1/HT48C30-1 28-pin SOP (300mil) Outline Dimensions 2 8 1 5 A B 1 1 4 C C ' G H D E a F · MS-013 Symbol Rev. 2.00 Dimensions in mil Min. Nom. Max. A 393 ¾ 419 B 256 ¾ 300 C 12 ¾ 20 C¢ 697 ¾ 713 D ¾ ¾ 104 E ¾ 50 ¾ F 4 ¾ 12 G 16 ¾ 50 H 8 ¾ 13 a 0° ¾ 8° 36 April 24, 2009 HT48R30A-1/HT48C30-1 Product Tape and Reel Specifications Reel Dimensions D T 2 A C B T 1 SOP 24W Symbol Description A Reel Outer Diameter Dimensions in mm 330.0±1.0 B Reel Inner Diameter 100.0±1.5 C Spindle Hole Diameter 13.0+0.5/-0.2 D Key Slit Width T1 Space Between Flange T2 Reel Thickness 2.0±0.5 24.8+0.3/-0.2 30.2±0.2 SOP 28W (300mil) Symbol Description Dimensions in mm A Reel Outer Diameter 330.0±1.0 B Reel Inner Diameter 100.0±1.5 C Spindle Hole Diameter 13.0+0.5/-0.2 D Key Slit Width T1 Space Between Flange T2 Reel Thickness Rev. 2.00 2.0±0.5 24.8+0.3/-0.2 30.2±0.2 37 April 24, 2009 HT48R30A-1/HT48C30-1 Carrier Tape Dimensions P 0 D P 1 t E F W C D 1 P B 0 K 0 A 0 R e e l H o le IC p a c k a g e p in 1 a n d th e r e e l h o le s a r e lo c a te d o n th e s a m e s id e . SOP 24W Symbol Description Dimensions in mm W Carrier Tape Width 24.0±0.3 P Cavity Pitch 12.0±0.1 E Perforation Position 1.75±0.1 F Cavity to Perforation (Width Direction) D Perforation Diameter 1.55+0.10/-0.00 D1 Cavity Hole Diameter 1.50+0.25/-0.00 P0 Perforation Pitch 4.0±0.1 P1 Cavity to Perforation (Length Direction) 2.0±0.1 A0 Cavity Length 10.9±0.1 B0 Cavity Width 15.9±0.1 K0 Cavity Depth 11.5±0.1 3.1±0.1 t Carrier Tape Thickness 0.35±0.05 C Cover Tape Width 21.3±0.1 SOP 28W (300mil) Symbol Description Dimensions in mm W Carrier Tape Width 24.0±0.3 P Cavity Pitch 12.0±0.1 E Perforation Position 1.75±0.10 F Cavity to Perforation (Width Direction) 11.5±0.1 D Perforation Diameter 1.5+0.1/-0.0 D1 Cavity Hole Diameter 1.50+0.25/-0.00 P0 Perforation Pitch P1 Cavity to Perforation (Length Direction) A0 Cavity Length 10.85±0.10 B0 Cavity Width 18.34±0.10 K0 Cavity Depth 2.97±0.10 t Carrier Tape Thickness 0.35±0.01 C Cover Tape Width 21.3±0.1 Rev. 2.00 4.0±0.1 2.0±0.1 38 April 24, 2009 HT48R30A-1/HT48C30-1 Holtek Semiconductor Inc. (Headquarters) No.3, Creation Rd. II, Science Park, Hsinchu, Taiwan Tel: 886-3-563-1999 Fax: 886-3-563-1189 http://www.holtek.com.tw Holtek Semiconductor Inc. (Taipei Sales Office) 4F-2, No. 3-2, YuanQu St., Nankang Software Park, Taipei 115, Taiwan Tel: 886-2-2655-7070 Fax: 886-2-2655-7373 Fax: 886-2-2655-7383 (International sales hotline) Holtek Semiconductor Inc. (Shanghai Sales Office) G Room, 3 Floor, No.1 Building, No.2016 Yi-Shan Road, Minhang District, Shanghai, China 201103 Tel: 86-21-5422-4590 Fax: 86-21-5422-4705 http://www.holtek.com.cn Holtek Semiconductor Inc. (Shenzhen Sales Office) 5F, Unit A, Productivity Building, Gaoxin M 2nd, Middle Zone Of High-Tech Industrial Park, ShenZhen, China 518057 Tel: 86-755-8616-9908, 86-755-8616-9308 Fax: 86-755-8616-9722 Holtek Semiconductor Inc. (Beijing Sales Office) Suite 1721, Jinyu Tower, A129 West Xuan Wu Men Street, Xicheng District, Beijing, China 100031 Tel: 86-10-6641-0030, 86-10-6641-7751, 86-10-6641-7752 Fax: 86-10-6641-0125 Holtek Semiconductor (USA), Inc. (North America Sales Office) 46729 Fremont Blvd., Fremont, CA 94538, USA Tel: 1-510-252-9880 Fax: 1-510-252-9885 http://www.holtek.com Copyright Ó 2009 by HOLTEK SEMICONDUCTOR INC. The information appearing in this Data Sheet is believed to be accurate at the time of publication. However, Holtek assumes no responsibility arising from the use of the specifications described. The applications mentioned herein are used solely for the purpose of illustration and Holtek makes no warranty or representation that such applications will be suitable without further modification, nor recommends the use of its products for application that may present a risk to human life due to malfunction or otherwise. Holtek¢s products are not authorized for use as critical components in life support devices or systems. Holtek reserves the right to alter its products without prior notification. For the most up-to-date information, please visit our web site at http://www.holtek.com.tw. Rev. 2.00 39 April 24, 2009