CPC1964BX6 Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter AC Operating Voltage Load Current On-State Voltage Drop Blocking Voltage Rating 20 - 240 1.5 1.4 600 Units Vrms Arms VP (at IL = 1.5AP) VP CPC1964BX6 is an AC Solid State Switch utilizing dual power SCR outputs. This device features Rapid Turn-On (non-zero-cross) control of the output SCRs, which makes it ideal for precisely switching AC loads independent of the load voltage phase. The optically coupled input and output circuits provide 5000Vrms of isolation and noise immunity between the control and load circuits. As a result, the CPC1964BX6 is well suited for industrial environments where electromagnetic interference would disrupt the operation of plant facility communication and control systems. Features • • • • • • • • • • • • • Description Load Current up to 1.5Arms 600VP Blocking Voltage High Surge Current: 15A Rapid Turn-On (Non-Zero-Cross Turn-On) 5mA Sensitivity Creepage Distance: 0.220" on Output Pins 12.5mm External Creepage Distance DC Control, AC Output Optically Isolated TTL and CMOS Compatible Low EMI and RFI Generation High Noise Immunity Machine Insertable, Wave Solderable Approvals • UL Recognized Component: File E69938 • CSA Certified Component: Certificate 1172007 Ordering Information Part # CPC1964BX6 Description 8-Pin Power SOIC (25/Tube) Applications • • • • • • • • • • • • • HVAC Control (Heating, Ventilation, Air Conditioning) Lighting Programmable Control Process Control Power Control Panels Remote Switching Gas Pump Electronics Contactors Large Relays Solenoids Motors Heaters Meters Pin Configuration 8 AC Load 7 6 AC Load 5 R 1 N/C 2 + LED 3 – LED 4 N/C Rapid Turn-On (Non Zero-Cross) Waveforms Control AC Load Voltage Load Current Voltage Across Relay DS-CPC1964BX6-R01 www.ixysic.com 1 INTEGRATED CIRCUITS DIVISION CPC1964BX6 Absolute Maximum Ratings @ 25ºC Parameter Blocking Voltage (VDRM) Reverse Input Voltage Input Control Current Peak (10ms) di/dt Critical Rate of Rise of On-State Current Input Power Dissipation 1 Total Power Dissipation 2 ESD, Human Body Model i2t Fusing Current (1/2 Sine Wave, 60Hz) Isolation Voltage, Input to Output Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / ºC 2 Derate linearly 20 mW / ºC Ratings 600 5 50 1 Units VP V mA A 20 A/s 150 2400 4 2 5000 -40 to +85 -40 to +125 mW mW kV A2s Vrms °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical Characteristics @ 25ºC Parameters Output Characteristics Load Current, Continuous Maximum Surge Current Off State Leakage Current On-State Voltage Drop Off-State dV/dt Switching Speeds Turn-on Turn-off Holding Current Latching Current Operating Frequency Input Characteristics Input Control Current to Activate 1 Input Drop-out Voltage Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance 1 2 Conditions Symbol Min Typ Max Units VL=20-240Vrms t < 16ms VDRM IL=1.5AP - IL IP 0.07 1000 1.21 - 1.5 15 100 1.4 - Arms A AP VP V/s ton toff IH IL 20 20 44 48 - 500 0.5 75 75 500 s cycles mA mA Hz 60Hz IF=5mA VR=5V IF VF IR 0.8 0.9 - 1.2 - 5 1.4 10 mA V V A - CI/O - - 3 pF IF = 5mA, Resistive VL=20V, 60Hz - ILEAK dV/dt For high-noise environments, or for high-frequency operation, use IF > 10mA. www.ixysic.com R01 INTEGRATED CIRCUITS DIVISION CPC1964BX6 PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)* 35 30 30 Device Count (N) 30 Device Count (N) Typical IF for Switch Operation Resistive Load (N=50, IL=1.5A, VL=120VAC 60Hz) On-State Forward Voltage Drop (N=50, IF=5mA, IL=1.5A) 25 20 15 10 25 20 15 10 5 5 0 0 1.25 1.26 1.27 1.28 1.29 LED Forward Voltage (V) 25 Device Count (N) 35 Typical LED Forward Voltage Drop (N=50, IF=5mA) 20 15 10 5 0 1.200 1.205 1.210 1.215 1.220 1.225 1.230 Forward Voltage (VP) 1.30 1.5 1.7 1.9 2.1 2.3 LED Current (mA) 2.5 2.7 Typical Blocking Voltage Distribution (N=50) Device Count (N) 25 20 15 10 5 0 747 Typical LED Forward Voltage Drop vs. Temperature Turn-On Time vs. Temperature 20 IF=5mA 1.3 1.2 Turn-On Time (Ps) 60 Turn-On Time (Ps) LED Forward Voltage (V) 768 70 IF=50mA IF=20mA IF=10mA IF=5mA 1.4 753 756 759 762 765 Blocking Voltage (VP) Typical Turn-On Time vs. LED Forward Current 1.6 1.5 750 50 40 30 20 15 IF=10mA 10 5 10 1.1 -40 -20 0 20 40 60 Temperature (ºC) 80 0 0 100 0 50 -40 -20 0 20 40 60 Temperature (ºC) 80 100 Typical IF for Switch Operation Resistive Load (IL=350mA, 60Hz) 2.9 LED Forward Current (mA) 10 20 30 40 LED Forward Current (mA) 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.1 -40 -20 0 20 40 60 Temperature (ºC) 80 100 * The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R01 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION CPC1964BX6 PERFORMANCE DATA @ 25ºC (Unless Otherwise Noted)* Holding Current (RL=1.9:) On-State Voltage vs. Temperature 1.25 60 50 40 30 IL=1.5A 1.15 1.10 IL=1A 1.05 1.00 IL=0.5A 0.95 20 -20 0 20 40 60 Temperature (ºC) 80 Maximum Load Current vs. Temperature (IF=5mA) -20 0 20 40 60 Temperature (ºC) 80 100 1.25 1.00 0.75 20 40 60 Temperature (ºC) 80 850 800 750 -40 Load Current (AP) 20 -0.5 0.0 0.5 1.0 1.5 10 900 100 -1.0 Typical Leakage Current vs. Temperature 700 0 @ 85ºC @ 25ºC @ -40ºC Load Voltage (V) 950 1.50 -20 2.5 2.0 1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5 -2.0 -2.5 -1.5 Blocking Voltage vs. Temperature Blocking Voltage (VP) 1.75 0.50 -40 -40 100 Leakage Current (PA) -40 Load Current (Arms) 1.20 Load Current (A) 70 On-State Voltage (VP) Holding current (mA) 80 Typical Load Current vs. Load Voltage (IF=5mA) -20 0 20 40 60 Temperature (ºC) 80 100 VL=600V VL=300V 1 0.1 0.01 0.001 -40 -20 0 20 40 60 Temperature (ºC) 80 100 Maximum Surge Current vs. Time TJ=50ºC Before Surge 15 10 5 0 100Ps 1ms 10ms 100ms 1s Time (ms) 10s 100s * The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R01 INTEGRATED CIRCUITS DIVISION CPC1964BX6 Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating CPC1964BX6 MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time CPC1964BX6 245ºC for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. R01 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION CPC1964BX6 MECHANICAL DIMENSIONS CPC1964BX6 21.082 ± 0.381 (0.830 ± 0.015) Pin 8 16.764 ± 0.381 (0.660 ± 0.015) 0.127 ± 0.076 (0.005 ± 0.003) 15.90 (0.626) 10.160 ± 0.254 (0.400 ± 0.010) 2.00 (0.079) 0.889 ± 0.127 (0.035 ± 0.005) Pin 1 0.762 ± 0.102 (0.030 ± 0.004) 5.080 ± 0.127 (0.200 ± 0.005) 7.620 ± 0.127 (0.300 ± 0.005) Recommended PCB Pattern 3.302 ± 0.051 (0.130 ± 0.002) 1.524 typ (0.060) 1.016 ± 0.127 (0.040 ± 0.005) 1.651 ± 0.102 (0.065 ± 0.004) 5.080 ± 0.127 (0.200 ± 0.005) 0.381 ± 0.025 (0.015 ± 0.001) Dimensions Unless Otherwise Noted mm Note: Pin-to-pin tolerances are non-cumulative. (inches) 5.080 (0.200) 7.622 (0.300) 5.080 (0.200) 0.95 (0.037) For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 6 Specification: DS-CPC1964BX6-R01 ©Copyright 2013, IXYS Integrated Circuits Division All rights reserved. Printed in USA. 10/23/2013