OPTOWAY XPS-2385W

Optoway
XPS-2385W-DXXXG
1
***********************************************************************************************************************************************************************
XPS-2385W-DXXXG
(RoHS Compliant)
10Gbps / 80 km / 50 GHz DWDM XFP Single-Mode Optical Transceiver for 10GbE / OC-192
**********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l
l
l
l
l
l
l
XPS-2385W-DXXXG series DWDM transceiver is
designed for single-mode fibre serial optical data
communications such as 10G Ethernet 10GBASE-ER/EW
and 10G Fibre Channel.
This module is designed for single mode fiber and
operates at a nominal wavelength of 50GHz ITU Grid, C
Band DWDM wavelength. The transmitter section consists
of a temperature-stabilized DWDM electrical-modulated
laser (EML), driver and signal conditioner. The receiver
section incorporates an avalanche photodiode (APD)
integrated with a trans-impedance preamplifier (TIA) and
signal conditioner.
The module is with the XFP 30-pin connector to allow
hot plug capability. Integrated Tx and Rx signal conditioners
provide high jitter-tolerance for full XFI compliance and no
external reference clock required. The internally ac coupled
high speed serial I/O simplifies interfacing to external
circuitry. Dual 5V and 3.3V power supply are used. The
optical output can be disabled by LVTTL logic high-level
input of TX_DIS. Loss of signal (RX_LOS) output is
provided to indicate the loss of an input optical signal of
receiver.
A serial EEPROM in the transceiver allows the user to
access transceiver digital diagnostic monitoring and
configuration data via the 2-wire XFP Management
Interface. This interface uses a single address, A0h, with a
memory map divided into a lower and upper area. Basic
digital diagnostic data is held in the lower area while specific
data is held in a series of tables in the high memory area.
l
l
l
l
l
l
Supports 9.95 Gbps to 10.5 Gbps
Complaint with XFP MSA
Compliant with XFI 10G Serial Electrical Interface
Maximum Link Length of 80 km
Temperature-stabilized DWDM EML Transmitter
50 GHz ITU Grid, C Band
2-Wire Interface for Integrated Digital Diagnostic
Monitoring
XFI Loopback Mode
No reference Clock required
Power Dissipation < 3.5 W
Dual 5V and +3.3 V Power Supply
RoHS-6 Compliant
-5 to 70oC Case Operating Temperature
APPLICATIONS
l 10GBASE-ER at 10.3125 Gb/s
l 10GBASE-EW at 9.953 Gb/s
l 80 km 10GFC at 10.51875 Gb/s
LASER SAFETY
This single-mode transceiver is a Class 1 laser product. It
complies with IEC-60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports
of the module shall be terminated with an optical connector
or with a dust plug.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
2
***********************************************************************************************************************************************************************
ORDER INFORMATION
P/No.
Bit Rate
(Gb/s)
XPS-2385W-DXXXG 9.95 – 10.52
10G
ZR / ZW
Distance
(km)
80
Spacing
(GHz)
50
Wavelength
(nm)
DWDM*
Package
Case Temp
RoHS
(oC)
Compliant
XFP with DMI
-5 to 70
Yes
*: XXX: 50GHz ITU Grid wavelength (Please see below)
Channel #
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
Product code
XPS-2385W-D200G
XPS-2385W-D205G
XPS-2385W-D210G
XPS-2385W-D215G
XPS-2385W-D220G
XPS-2385W-D225G
XPS-2385W-D230G
XPS-2385W-D235G
XPS-2385W-D240G
XPS-2385W-D245G
XPS-2385W-D250G
XPS-2385W-D255G
XPS-2385W-D260G
XPS-2385W-D265G
XPS-2385W-D270G
XPS-2385W-D275G
XPS-2385W-D280G
XPS-2385W-D285G
XPS-2385W-D290G
XPS-2385W-D295G
XPS-2385W-D300G
XPS-2385W-D305G
XPS-2385W-D310G
XPS-2385W-D315G
XPS-2385W-D320G
XPS-2385W-D325G
XPS-2385W-D330G
XPS-2385W-D335G
XPS-2385W-D340G
XPS-2385W-D345G
XPS-2385W-D350G
XPS-2385W-D355G
XPS-2385W-D360G
XPS-2385W-D365G
XPS-2385W-D370G
XPS-2385W-D375G
XPS-2385W-D380G
XPS-2385W-D385G
XPS-2385W-D390G
XPS-2385W-D395G
XPS-2385W-D400G
XPS-2385W-D405G
XPS-2385W-D410G
XPS-2385W-D415G
XPS-2385W-D420G
XPS-2385W-D425G
XPS-2385W-D430G
XPS-2385W-D435G
XPS-2385W-D440G
XPS-2385W-D445G
Frequency (THz)
192.00
192.05
192.10
192.15
192.20
192.25
192.30
192.35
192.40
192.45
192.50
192.55
192.60
192.65
192.70
192.75
192.80
192.85
192.90
192.95
193.00
193.05
193.10
193.15
193.20
193.25
193.30
193.35
193.40
193.45
193.50
193.55
193.60
193.65
193.70
193.75
193.80
193.85
193.90
193.95
194.00
194.05
194.10
194.15
194.20
194.25
194.30
194.35
194.40
194.45
Center Wavelength (nm)
1561.42
1561.01
1560.61
1560.20
1559.79
1559.39
1558.98
1558.58
1558.17
1557.77
1557.36
1556.96
1556.55
1556.15
1555.75
1555.34
1554.94
1554.54
1554.13
1553.73
1553.33
1552.93
1552.52
1552.12
1551.72
1551.32
1550.92
1550.52
1550.12
1549.72
1549.32
1548.91
1548.51
1548.11
1547.72
1547.32
1546.92
1546.52
1546.12
1545.72
1545.32
1544.92
1544.53
1544.13
1543.73
1543.33
1542.94
1542.54
1542.14
1541.75
Label
200
205
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
300
305
310
315
320
325
330
335
340
345
350
355
360
365
370
375
380
385
390
395
400
405
410
415
420
425
430
435
440
445
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
3
***********************************************************************************************************************************************************************
Channel #
450
455
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
570
575
580
585
590
595
600
Product code
XPS-2385W-D450G
XPS-2385W-D455G
XPS-2385W-D460G
XPS-2385W-D465G
XPS-2385W-D470G
XPS-2385W-D475G
XPS-2385W-D480G
XPS-2385W-D485G
XPS-2385W-D490G
XPS-2385W-D495G
XPS-2385W-D500G
XPS-2385W-D505G
XPS-2385W-D510G
XPS-2385W-D515G
XPS-2385W-D520G
XPS-2385W-D525G
XPS-2385W-D530G
XPS-2385W-D535G
XPS-2385W-D540G
XPS-2385W-D545G
XPS-2385W-D550G
XPS-2385W-D555G
XPS-2385W-D560G
XPS-2385W-D565G
XPS-2385W-D570G
XPS-2385W-D575G
XPS-2385W-D580G
XPS-2385W-D585G
XPS-2385W-D590G
XPS-2385W-D595G
XPS-2385W-D600G
Frequency (THz)
194.50
194.55
194.60
194.65
194.70
194.75
194.80
194.85
194.90
194.95
195.00
195.05
195.10
195.15
195.20
195.25
195.30
195.35
195.40
195.45
195.50
195.55
195.60
195.65
195.70
195.75
195.80
195.85
195.90
195.95
196.00
Center Wavelength (nm)
1541.35
1540.95
1540.56
1540.16
1539.77
1539.37
1538.98
1538.58
1538.19
1537.79
1537.40
1537.00
1536.61
1536.22
1535.82
1535.43
1535.04
1534.64
1534.25
1533.86
1533.47
1533.07
1532.68
1532.29
1531.90
1531.51
1531.12
1530.72
1530.33
1529.94
1529.55
Label
450
455
460
465
470
475
480
485
490
495
500
505
510
515
520
525
530
535
540
545
550
555
560
565
570
575
580
585
590
595
600
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
4
***********************************************************************************************************************************************************************
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Case Temperature
Relative Humidity
Power Supply Voltage (5V)
Power Supply Voltage (3.3V)
Receiver Input Optical Power
Symbol
Tstg
Topr
RH
Vcc5
VCC3
Mip
Min
-40
-5
0
-0.5
-0.5
Max
85
70
85
6.0
3.6
4
Units
o
C
o
C
%
V
V
dBm
Notes
Non condensing
Received average power
Recommended Operating Conditions
Parameter
Symbol
Min
Typ
VCC5
Power Supply Voltage (5V)
4.75
5
VCC3
Power Supply Voltage (3.3V)
3.13
3.3
ICC5
Power Supply Current (@5V)
ICC3
Power Supply Current (@3.3V)
Power Dissipation
PD
Operating Case Temperature
Topr
-5
Data Rate
9.95
10.3125
1. Including in rush current. Maximum module current ramp rate is 100 mA/µs.
Max
5.25
3.47
300
750
3.5
70
10.5
Units / Notes
V
V
mA / 1
mA / 1
W
o
C
Gb/s
Transmitter Optical Specifications (Topr= -5 to 70oC, Vcc5=5V±5%, Vcc3 = 3.3V ±5%)
Parameter
Average Launch Power
Extinction Ratio
Center Wavelength Spacing
Transmitter Center Wavelength
-- over life time
Output Spectrum Width
Side Mode Suppression Ratio
Transmitter and Dispersion
Penalty @ -500 to 1600 ps/nm
Relative Intensity Noise
Eye Mask 1
Average Launch Power of OFF
Transmitter
Symbol
Po, Avg
ER
Min
0
8.2
λc
X-60
σλ
SMSR
TDP
30
Typ
Max
+4
50
X
X+60
Units
dBm
dB
GHz
pm
1
RIN
3
nm
dB
dB
-130
dB/Hz
IEEE 802.3ae
Notes
2
3
-20 dB width
10G Ethernet
-30
dBm
2. Output power is power coupled into a 9/125 µm single-mode fiber.
3. X = specified ITU Grid wavelength. Wavelength stability is achieved within 60 seconds of power up.
Receiver Optical Specifications (Topr= -5 to 70oC, Vcc5=5V±5%,Vcc3 = 3.3V ±5%)
Parameter
Sensitivity
Receiver Overload
LOS -- Deasserted
LOS -- Asserted
LOS -- Hysteresis
Wavelength of Operation
Optical Return Loss
Symbol
Sen
PMAX
LOSD
LOSA
λc
ORL
Min
Typ
-7
---36
0.5
1260
---------
Max
-23
-28
--1620
-27
Units
dBm
dBm
dBm
dBm
dB
nm
dB
Notes
4
Transition: low to high
Transition: high to low
4. Measured with worst ER; BER < 10-12 and PRBS 231-1.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
5
***********************************************************************************************************************************************************************
Electrical Characteristics
Parameter
Symbol
Min
Typ
Max
High-Speed Signal (CML) Interface Specification
Input Data Rate
9.95
10.3125
10.5
Differential Input Impedance
Rin
100
Differential Data Input Amplitude
120
820
Output Data Rate
9.95
10.3125
10.5
Differential Output Impedance
Rout
100
Differential Data Output
340
650
850
Amplitude
Low-Speed Signal (LVTTL) Interface Specification
Input High Voltage
2.0
Vcc
Input Low Voltage
GND
0.8
Output High Voltage
2.4
Vcc
Output Low Voltage
GND
0.5
Reference Clock (LVPECL) Interface Specification
No reference clock required.
Units
Notes
Gb/s
Ω
mVpp
Gb/s
Ω
mVpp
6
7, Internally AC coupled
6
7, Internally AC coupled
V
V
V
V
6. 10GBASE-ER/EW and 10G Fibre Channel.
7. The differential input and output amplitudes are per XFP MSA mask at points B’ and C’.
Transceiver Timing Characteristics
Parameter
TX_DIS Assert Time
TX_DIS Negate Time
Time to Initialize
Interrupt Assert Delay
Interrupt Negate Delay
P_Down/PST Assert Delay
P_Down Nagate Delay
Mod_NR Assert Delay
Mod_NR Negate Delay
Mod_Desel Assert Time
Mod_Desel De-Assert Time
P_Down Reset Time
RX_LOS Assert Delay
RX_LOS Negate Delay
Serial ID Clock Rate
Symbol
t_off
t_on
t_init
interrupt_on
interrupt_off
P_Down/RST_on
P_Down/RST_off
Mod_nr_on
Mod_nr_off
T_Mod_Desel
T_Mod_Sel
T_reset
T_Los_on
T_Los_off
fSCL
Min
Typ
Max
10
2
300
200
500
100
300
1
1
2
2
10
0
100
100
400
Units
µs
ms
ms
ms
µs
µs
ms
ms
ms
ms
ms
µs
µs
µs
kHz
Notes
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
6
***********************************************************************************************************************************************************************
MANAGEMENT INTERFACE
The structure of the memory map is shown in Figure 1, which is accessible over a 2-wire serial interface at the 8-bit
address 1010000X (A0h). The normal 256 byte I2C address space is divided into low and upper blocks of 128 Bytes. The
lower block of 128 Bytes is always directly available and is used for the diagnostics and control function. Multiple blocks of
memories are available in the upper 128 Bytes of the address space. These are individually addressed through a table select
Byte which the user enters into a location in the lower address space. Thus, there is a total available address space of 128*256
= 32 Kbytes in this upper memory space. The contents of Table 01h are listed in Table 1 below. Please refer SFF INF-8077i
(Revision 4.5) for detailed information.
Figure 1. 2-wire Serial Digital Diagnostic Memory Map
Data Address
96 ~ 97
98 ~ 99
100 ~ 101
102 ~ 103
104 ~ 105
106 ~ 107
Table 1 Monitoring Specification
Parameter
Accuracy
± 3oC
Temperature
Reserved
Tx Bias
Tx Power
Rx Power
Vcc3
± 10%
± 2dB
± 2dB
± 3%
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
7
***********************************************************************************************************************************************************************
CONNECTION DIAGRAM
Table 3 PIN Description
PIN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Logic
LVTTL-I
LVTTL-O
LVTTL-I
LVTTL-I/O
LVTTL-I/O
LVTTL-O
LVTTL-O
LVTTL-O
CML-O
CML-O
Signal Name
GND
VEE5
Mod_Desel
Interrupt
TX_DIS
VCC5
GND
VCC3
VCC3
SCL
SDA
Mod_Abs
Mod_NR
RX_LOS
GND
GND
RDRD+
GND
VCC2
Description
Note
Module Ground
-5.2V Power Supply (Not required)
Module De-select; When held low allows module to respond to 2-wire serial interface
Interrupt; Indicates presence of an important condition which can be read over the
2wire serial interface
Transmitter Disable; Turns off transmitter laser output
+5V Power Supply
Module Ground
+3.3V Power Supply
+3.3V Power Supply
Serial 2-wire interface clock
Serial 2-wire interface data line
Indicates Module is not present. Grounded in the Module
Module Not Ready; Indicating Module Operational Fault
Receiver Loss Of Signal Indicator
Module Ground
Module Ground
Receiver Inverted Data Output
Receiver Non-Inverted Data Output
Module Ground
+1.8V Power Supply (Not required)
1
3
2
3
1
2
2
2
2
2
1
1
1
3
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
8
***********************************************************************************************************************************************************************
21 LVTTL-I
P_Down/RST
22
23
24 PECL-I
VCC2
GND
RefCLK+
25 PECL-I
RefCLK-
26
27
28 CML-I
29 CML-I
30
GND
GND
TDTD+
GND
Power down; When high, requires the module to limit power consumption to 1.5W or
below. 2-Wire serial interface must be functional in the low power mode.
Reset; The falling edge initiates a complete reset of the module including the 2-wire
serial interface, equivalent to a power cycle.
+1.8V Power Supply (Not required)
Module Ground
Reference Clock Non-Inverted Input, AC coupled on the host board. (Not used.
Internally terminated to 50 ohm (100 ohm diff.))
Reference Clock Inverted Input, AC coupled on the host board. (Not used. Internally
terminated to 50 ohm (100 ohm diff.))
Module Ground
Module Ground
Transmitter Inverted Data Input
Transmitter Non-Inverted Data Input
Module Ground
3
1
4
4
1
1
1
1. Module ground pins GND are isolated from the module case and chassis ground within the module.
2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board.
3. These PINs are open within module.
4. A Reference Clock input is not required. If present, it will be ignored.
MECHANICAL SPECIFICATION (UNITS IN MM)
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
9
***********************************************************************************************************************************************************************
RECOMMENDED POWER CIRCUIT SCHEMATIC
Host Board
VCC5
Optional
Host +5V
4.7μH
0.1μF
VCC3
Host +3.3V
4.7μH
22μF
0.1μF
0.1μF
VCC2
Optional
Host +1.8V
4.7μH
22μF
0.1μF
XFP Connector
22μF
0.1μF
XFP Module
0.1μF
VEE5
Optional
Host -5.2V
4.7μH
0.1μF
22μF
0.1μF
RECOMMENDED INTERFACE CIRCUIT
XFP module
Host Board
SerDat Out+
TD +
Z=50Ω
CML
100Ω
CML
TD -
SerDat OutZ=50Ω
SerDat In+
CML
RD +
Z=50Ω
100Ω
CML
SerDat In-
RD Z=50Ω
Vcc(+3.3V)
REFCLKP
100Ω
4.7K to 10KΩ
REFCLKN
RX_LOS
INTERRUPT
SDA
VCC(+3.3V)
SCL
MOD_NR
10KΩ
MOD_abs
TX_DIS
GND
MOD_DeSel
P_Down/RST
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
10
***********************************************************************************************************************************************************************
Table 2 Serial ID Memory Contents (Table 01h)
Address
Field
Size
(Byte)
128
1
Identifier
129
130
1
1
Ext. Identifier
Connector type
131~138
139
140
141
142
143
144
145
146
147
8
1
1
1
1
1
1
1
1
1
Transceiver
Encoding
BR-Min
BR-Max
length (SMF)-Km
Length (E-50µm)
Length (50 µm)
Length (62.5 µm)
Length (Copper)
Device Tech
148~163
164
165~167
16
1
3
Vendor name
CDR Support
Vendor OUI
168~183
184~185
186~187
16
2
2
188~189
190
191
2
1
1
Vendor PN
Vendor rev
Wavelength
Wavelength
Tolerance
Max Case Temp
CC_BASE
192~195
4
Power Supply
196~211
16
Vendor SN
212~219
8
220
1
Date code
Diagnostic
Monitoring Type
221
222
223
224~255
1
1
1
32
Enhanced Options
Aux Monitoring
CC_EXT
Vendor Specific
Name of Filed
Description
Hex
XFP
power consumption < 3.5W, no Ref Colck
required
LC connector
10GBASE-ER/EW, 10GFC 1200-SM-LL-V
10G SONET/SDH
64B/66B, 8B10B, SONET Scrambled & NRZ
9.9Gbps
10.5Gbps
80 Km
0m
0m
0m
0m
DWDM EML, APD detector
06
+/- 0.06nm
70deg
Check sum of Byte 128 -- 190
3.5 Wmax, 1.5W pd_max , 750mA 3.3V, 500
mA 5V
000C
46
90
07
22 20 00 00 00 00 00 00
F0
63
69
50
00
00
00
00
76
4F 50 54 4F 57 41 59 20
OPTOWAY
20 20 20 20 20 20 20 20
CDR supports 9.953G ~ 10.5G & XFI Loopback E1
00 0E FA
58 50 53 2D 32 33 38 35
XPS-2385W-DXXXG
57 2D 44 3X 3X 3X 47 20
ASCII (“31 61” means 1a revision)
xx xx
1XXX.XXnm
xx xx
ASCII
ASCII Year (2 Byte), Month (2 Byte), Day (2
Byte)
No BER Support, Average Power
Optional Soft TX_DISABLE implemented,
Optional Soft P_down implemented
AUX1 for Vcc3, AUX2 for Vcc5
Check sum of Byte 192 -- 222
AF 96 A8 00
xx xx xx xx xx xx xx xx
xx xx xx xx xx xx xx xx
xx xx xx xx xx xx 20 20
08
60
76
Reserved
Note: Specifications subject to change without notice.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0
Optoway
XPS-2385W-DXXXG
11
***********************************************************************************************************************************************************************
REVISION HISTORY
Version
1.0
2.0
Subject
Release Date
Initial datasheet
Change the TX wavelength stability to +/- 60 pm
2010/7/1
2012/9/1
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
E-mail: [email protected]
Fax: 886-3-5979737
http: // www.optoway.com.tw 9/1/2012
V2.0