RHOMBUS-IND T

10BASE T ISOLATION TRANSFORMER
Electrical Specifications at 25OC
Turns Ratio
Fast Rise Times
1CT : 1.41CT (Pins 6-8:11-9)1
1CT : 1CT (Pins 1-3:16-14)2
+5%
PARAMETER
MIN.
MAX.
Open Circuit Inductance (1-3)
@ 100 kHz-20mV
110
µH
Open Circuit Inductance (6-8)
@ 100 kHz-20mV
110
µH
Leakage Inductance (1-3, Short 16-14)
@ 100 kHz-20mV
0.4
µH
Leakage Inductance (6-8, Short 11-9)
@ 100 kHz-20mV
0.4
µH
Interwinding Capacitance
@ 100 kHz-20mV (1-3 to 14-16)
15
pF
Interwinding Capacitance
@ 100 kHz-20mV (6-8 to 11-9)
15
pF
DC Resistance Primary
1.0
ohms
HI-POT
1500
Meets ECMA Requirements
UNITS
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
SCHEMATIC DIAGRAM
VRMS
RECEIVE
1. Transmit
2. Receive
1
16
2
15
14
3
TRANSMIT
6
13
10
7
Dimensions in inches (mm)
8
11
12
9
RHOMBUS P/N: T-14961
CUST P/N:
DATE: 12/10/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com