SLPOWER CINT3110A1708K01

CINT3110
110W Triple Output
Industrial Series
Features

2” x 4” x 1.3” Package

Suitable for 1U Applications

110W w/air, 80W convection cooled

Universal Input 90-264Vac

Efficiency 87% typical

Approved to CSA/EN/IEC/UL60950-1,
2nd Edition

Power Fail Signal

Remote Sense

3 Year Warranty

RoHS Compliant
Description
The CINT3110 Series are industrial grade, high efficiency, triple output power supplies in a small 2” x 4” size. The
CINT3110 family is ideal for Industrial and ITE applications requiring multiple outputs and small footprint. Compliant to
nd
IEC60950-1 2 edition, the CINT3110 models feature outputs of 5/±12V, 5/±15V, 5/±24V, includes a Power Fail/DC OK
signal, and meet Class B Conducted EMI.
Model Selection
Model
Number
CINT3110A0508K01
CINT3110A1708K01
CINT3110A1908K01
Notes:
Volts*
Output Current**
w/200LFM air
Convection
Ripple &
Noise***
Total
Regulation
OVP
Threshold
V1
5V
14.0A
10.0A
1.0% pk-pk
2%
7.5V max.
V2
12V
6.0A
4.5A
1.0% pk-pk
3%
115%-135%
V3
-12V
1.0A
1.0A
2.0% pk-pk
10%
115%-135%
V1
5V
14.0A
10.0A
1.0% pk-pk
2%
7.5V max.
V2
15V
4.5A
3.5A
1.0% pk-pk
3%
115%-135%
V3
-15V
1.0A
1.0A
2.0% pk-pk
10%
115%-135%
V1
5V
12.0A
8.0A
1.0% pk-pk
2%
7.5V max.
V2
24V
4.0A
3.0A
1.0% pk-pk
3%
115%-135%
V3
-24V
1.0A
1.0A
2.0% pk-pk
10%
115%-135%
* 5V output is adjustable with +/-10% range
** Total convection power is 80 Watts.
*** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors. Ripple & Noise of V2 at
no load is 2% maximum.
General Specifications
AC Input
Input Current
www.slpower.com
100-240Vac, ±10%, 47-63Hz, 1
120–370Vdc
Turn On Time
Less than 2 sec. @115Vac (inversely
proportional to input voltage and thermistor
temperature)
115Vac: 1.5A, 230Vac: 0.75A
Hold-up Time
16mS typical at 110W, 120Vac input
CINT3110 REV 1.1, 26-NOV-12
1
CINT3110
110W Triple Output
Industrial Series
General Specifications (continued)
Inrush Current
Input Fuses
Earth Leakage
Current
Efficiency
Output Power
Transient
Response
Signals
264Vac, cold start: will not exceed 45A
Overload
Protection
F1, F2: 2.5A, 250Vac fuses provided on all
models
Short Circuit
Protection
<290μA@264Vac, 60Hz, NC
Overvoltage
Protection
87% typical at 230Vac
110W continuous with 200 lfm airflow, 80W
convection cooled – See chart for specific
voltage model ratings.
Switching
Frequency
500µS typ. for return to within 0.5% of
nominal, 50% load step. i/t <0.2A/μS.
Max Volt Deviation = 3%
Isolation
AC Power Fail, DC OK
150%-300% above rating for V2 & V3, 110%200% for V1. Hiccup Mode
Provided - no damage will occur if the output is
shorted.
See models chart for trip range.
PFC: 75kHz typical
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
Ripple and Noise
See models chart
Operating
Temperature
-10°C to +70°C
Output Voltage
See models chart
Temperature
Derating
Derate output power linearly above 50°C to 50%
at 70°C
+/-10% from nominal on 5V output
Storage
Temperature
-40°C to +85°C
Voltage
Adjustability
Minimum Load
Total Regulation
Vibration
Dimensions
Weight
Altitude
Not required
Relative Humidity
See models chart
Operating: 0.003g²/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Shock
Safety Standards
W: 2.0” x L: 4.0” x H: 1.3”
MTBF
200g
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
245,000 hours, 25°C Ambient, 110Vac input
Auxiliary Signals
AC Power Fail:
During normal operation, stays HIGH. Signal
goes LOW with at least 6mS warning before
loss of DC output from AC failure.
Remote Sense:
(5V output, optional) Will compensate for 0.5V
drop min. Will operate without remote sense
connected. Reverse connection protected.
DC OK:
Open collector logic signal goes and stays HIGH
100mS to 500mS after main output reaches
regulation.
Notes:
1. Specifications are for convection rating at factory settings at 115 Vac input, 25°C ambient unless otherwise stated.
2. For DC input an external DC safety rated fuse must be used.
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
2
CINT3110
110W Triple Output
Industrial Series
EMI/EMC Compliance
Conducted Emissions
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55011/22 Class A; FCC Part 15, Subpart A, Class A
Static Discharge Immunity
EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m. Criteria A
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz, Criteria A
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A
Conducted RF Immunity
EN61000-4-6, 3Vrms, Criteria A
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m, Criteria A
Voltage Dip Immunity
EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles;
Criteria A
Line Harmonic Emissions
EN61000-3-2, Class A, B, C, & D
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes:
1. All dimensions in inches (mm), tolerance is ±.02”.
2. Mounting holes should be grounded for EMI purpose
3. Mounting J101 is safety ground connection
4. This power supply requires mounting on metal standoffs 0.20” (5 m) in height.
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
3
CINT3110
110W Triple Output
Industrial Series
Connector Information
Input Connector
J100
Ground
J101
DC Output Connector
J200
PIN 1) AC NEUTRAL
PIN 2) EMPTY
PIN 3) AC LINE
0.187” FASTON TAB
PIN 1) +V1
PIN 2) +V1
PIN 3) GND
PIN 4) GND
PIN 5) GND
PIN 6) GND
Mating Connector:
Molex 09-50-3031
Pins= 08-52-0072
Mating Connector:
Molex 01-90020001
Mating Connector:
JST VHR-8N
Pins = SVH-21T-P1.1
Signal Connector
J300
PIN 7) V2
PIN 8) V3
PIN 1) Power Fail/DC OK
PIN 2) GND
PIN 3) +Remote Sense
PIN 4) –Remote Sense
Mating Connector:
Molex 51065-0400
Pins = 50212-8100
Isolation Specifications
Parameter
Conditions/Description
Insulation Safety Rating
Input/Ground
Input/Output
Output/Ground
Electric Strength Test Voltage
Input/Ground
Input/Output
Output/Ground
Min
Nom
Max
Units
-
Vac
Vac
Vac
Basic
Reinforced
Operational
1800
4000
500
-
Leakage Current
Parameter
Conditions/Description
Max
Earth Leakage Current
Normal Condition (NC)
Single Fault Condition (SFC)
290µA
420µA
Touch Current
Normal Condition (NC)
Single Fault Condition (SFC)
90µA
170µA
Input Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Min
Nom
Max
Units
Input Voltage
90
115/230
264
Vac
Input Frequency
47
50/60
63
Hz
Input Current
115Vac/max load
1.5
A
Input Current
230Vac/max load
0.75
A
Inrush Current
264Vac, cold start, 25°C
-
-
45
A
Efficiency
Vi nom, Io nom
CINT3110A0508K01
CINT3110A1708K01
CINT3110A1908K01
-
87%
-
%
Parameter
Conditions/Description
Min
Nom
Max
Units
Output Current V1
Output Current V2
Output Current V3
CINT3110A0508K01
0
0
0
10.0
4.5
1
14.0
6.0
1
ADC
Output Current V1
Output Current V2
Output Current V3
CINT3110A1708K01
0
0
0
10.0
3.5
1
14.0
4.5
1
ADC
Output Current V1
Output Current V2
Output Current V3
CINT3110A1908K01
0
0
0
8.0
3.0
1
12.0
4.0
1
ADC
Output Specifications
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
4
CINT3110
110W Triple Output
Industrial Series
Output Specifications (continued)
Parameter
Conditions/Description
Min
Nom
Max
Units
Static Line Regulation V1
Vi min-Vi max, Vi nom, 0-100% Io1 max
-2
-
2
% Vo nom
Static Line Regulation V2
Vi min-Vi max, Vi nom, 0-100% Io2 max
-3
-
3
% Vo nom
Static Line Regulation V3
Vi min-Vi max, Vi nom, 0-100% Io3 max
-10
-
10
% Vo nom
Static Load Regulation V1
(Droop Characteristic)
Vi min-Vi max, Vi nom, 0-100% Io1 max
-2
-
2
% Vo nom
Static Load Regulation V2
(Droop Characteristic)
Vi min-Vi max, Vi nom, 0-100% Io2 max
-3
-
3
% Vo nom
Static Load Regulation V3
(Droop Characteristic)
Vi min-Vi max, Vi nom, 0-100% Io3 max
-10
-
10
% Vo nom
Hold-Up Time
Vin = 120Vac, Po = 110W
16
-
-
mS
Dynamic Load Regulation V1, V2, V3
Load change =50%, di/dt = 0.2A/μS
0
3
% Vo nom
Start-Up Time
Vin = 115Vac, Io nom
0
2
S
Ripple & Noise V1
20MHz bandwidth
0
1%
% Vo nom
Ripple & Noise V2
20MHz bandwidth
0
1%
% Vo nom
Ripple & Noise V3
20MHz bandwidth
0
2%
% Vo nom
Max
Units
-
Protection
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter
Conditions/Description
Input Fuse
T2.5A/250V internal fuse in both line & neutral
Min
Input Transient Protection
2KV(CM) and 1KV(DM) surge
Nom
Not user accessible
2
Short Circuit Protection
Hiccup Mode
Overload Protection
Hiccup Mode
Overvoltage Protection
Latching Type, recycle AC input to reset
Characteristic Curves
KV (CM)
See models chart for trip ranges
(Note: All waveforms below are based on CINT3110A0508K01 model)
Output vs. Temperature
80W convection cooled and 110W continuous with 200 LFM airflow. Derate output power to 50% at 70C.
Output Power (W)
120
100
80
60
40
20
0
-10
0
10
20
30
40
50
60
70
Temperature (°C)
Convection
www.slpower.com
200LFM Cooling
CINT3110 REV 1.1, 26-NOV-12
5
CINT3110
110W Triple Output
Industrial Series
Ripple & Noise
To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with
0.1µF ceramic and a 10µF electrolytic capacitor connected in parallel across it, BW limit with 20MHz.
Output Transient Response V1
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%.
Output Transient Response V2
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%.
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
6
CINT3110
110W Triple Output
Industrial Series
Output Transient Response V3
50% load step within the regulation limits of minimum and maximum load, di/dt<0.2A/μSec. Recovery time not specified as there is no laps in regulation
with a 50% Load Step. Maximum voltage deviation is 3%.
Output Overload Characteristic V1
Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention.
Output Overload Characteristic V2
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
7
CINT3110
110W Triple Output
Industrial Series
Output Overload Characteristic V3
Output Short Circuit Characteristic V1
Supply shall protect itself against Short Circuit conditions. The Power Supply shall recover from short circuit conditions without operator intervention.
Output Short Circuit Characteristic V2
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
8
CINT3110
110W Triple Output
Industrial Series
Output Short Circuit Characteristic V3
Output Overvoltage Characteristic V1
Supply shall protect itself against over voltage conditions. The Power Supply shall latch and require AC input recycle to reset.
AC input 90V 60Hz
AC input 264V 50Hz
Output Overvoltage Characteristic V2
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
9
CINT3110
110W Triple Output
Industrial Series
Output Overvoltage Characteristic V3
Startup Time
Hold-up Time
Start up time is <2seconds
Hold up time is 16mS minimum
Power Fail Signal Timing
Active Low TTL logic signal goes high 100 - 500 ms after main output; it goes low at least 6 mS before loss of regulation.
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
CINT3110 REV 1.1, 26-NOV-12
10