MAP140 SERIES Power-One’s MAP140 series provides a full range of options and up to 30 watts more power than comparable products in this industry standard footprint. With a universal input from 85 to 264 VAC and power densities up to 2.6 watts/inch3, the MAP140 meets the most rigorous requirements of commercial, industrial, and datacom systems. Rated for use in convection and forced air cooled (200 LFM) applications, the MAP140 delivers dependable power with a Mean Time Before Failure (MTBF) in excess of 180,000 hours. In addition to UL, CSA, and TÜV regulatory compliance, the MAP140 displays the CE Mark. FEATURES • Universal Input 85-264 VAC • Input Transient & ESD Compliance to EN61000-4-2/-3/-4 • CE Marked to Low Voltage Directive • Industry Standard Footprint: 7.00" x 4.30" x 1.80" (177.8mm x 109.2mm x 45.7mm) • Remote Sense and Overvoltage Protection • Power Fail Signal Standard on MAP140-3000P, Optional on MAP140-1012 and MAP140-1024 • Optional Overtemperature Protection, L-Bracket, and Cover. SINGLE OUTPUT MODEL SELECTION CHART MODEL MAP140-1012 MAP140-1024 MAP140-1048 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT FORCED AIR CURRENT (NOTE 3) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY 12V/15V 24V/28V 48V 11.0V to 16.0V 22.8V to 29.2V 45.6V to 54.0V 9.2/7.3A (Note 2) 4.6/4A (Note 2) 2.3A 12.5A/10A (Note 2) 6.3A/5.4A (Note 2) 3.1A 0.1% 0.1% 0.1% 0.5% 0.5% 0.5% 1% 1% 1% 11.97V to 12.03V 23.95V to 24.05V 47.9V to 48.1V NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation. 3) With 200 LFM forced air cooling. MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 140W FORCED AIR COOLED (200 LFM) MODEL MAP140-3000P OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V -12V 4.75 - 5.25V Fixed Fixed 16A/25A 4A/9A PK 1A/1.5A PK 20A/25A PK 4A/9A PK 1A/1.5A PK 0.2% 0.1% 0.1% 1% 2% 2% 1% 1% 1% 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Brown Out Protection Hold-up Time 85 47 85 20 16 Input Protection Inrush Surge Current Continuous input range. AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC input voltage (110 VAC) 110 watt load: 140 watt load: 85 VAC (140W load). 110 VAC (140W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264VAC (one cycle). 25°C. Operating Frequency Switching frequency of main transformer. Input Current NOM MAX UNITS 264 63 VAC Hz VAC mS 2.5 2.0 41 22 ARMS APK kHz NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. Rev. 04/2000 1 MAP140 SERIES OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Efficiency Minimum Loads Full load, 110 VAC. Varies with distribution of loads among outputs. 65 Single output models. 0 MAP140-3000P, total output current of V1 + V2 (Note 1). 2 Full load, 20MHz bandwidth. Single output models. MAP140-3000P with convection cooling. MAP140-3000P with 200 LFM forced air cooling. Output voltage overshoot/undershoot at turn-on/turn-off. Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. Time required for initial output voltage stabilization. MAP140-3000P Single output models Time required for output voltage to rise from 10% to 90%. Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time MIN NOM MAX UNITS 70 80 % Amps See Model Selection Chart. See Model Selection Chart. 80 Watts 140 0 V See Model Selection Chart. 500 µS 1 2 20 Sec mS NOTES: 1) Minimum load is required only to meet the regulation limits of V3. INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Provided on single output models and V1 of MAP140-3000P. Overload Protection Remote Sense Input Power Fail Warning Overtemperature Protection MIN NOM MAX MAP140-3000P, V1 6.1 7.2 MAP140-1012 17.3 20.2 MAP140-1024 32.2 37.8 MAP140-1048 55.2 64.8 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Voltage drop compensated for at the load. 250 TTL compatible logic signal. Time before regulation dropout due to loss of input power at 140 watts, 110 VAC. Standard on MAP140-3000P 2.3 and optional on MAP140-1012. Optional signal provides system shutdown due to excessive internal temperature. See options. UNITS V mV mS SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference, Conducted ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 No. 234/950. EN60950 (TÜV). Input to output, 1 second. FCC CFR title 47 part 15 sub-part B - conducted & radiated. EN55022 / CISPR 22 conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. MIN Insulation Resistance Leakage Current Input to Output. Per EN60950, 264VAC. NOM MAX UNITS Approved Line to Line Line to Ground 2600 B B 8 10 ±2 1 2 10 VDC Class kV V/M kV kV MΩ 110 VAC 264 VAC 0.5 1.5 mA ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Altitude Operating Temperature Operating. Non-operating. Derate linearly above 50°C by 2.5% per °C Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration 0°C to 70°C (after 15 minute warm-up period). Non-condensing. Operating, peak acceleration. Random vibration, 10Hz to 2kHz, 3 axis. MIN At 100% load: At 50% load: NOM 0 0 -40 ±0.02 2 MAX UNITS 10k 40k 50 70 85 ±0.05 95 20 6 ASL Ft. ASL Ft. °C °C °C %/°C %RH GPK GRMS MAP140 SERIES OPTIONS DESCRIPTION NOTES L-Bracket Add ‘L’ suffix to model number. Cover Add ‘C’ suffix to model number. Includes L-Bracket. For convection cooled applications, derate output power to 75 watts, maximum. Add ‘P’ suffix to model number. Provides 2.3mS warning time before main output drops 5%. Warning time increases at reduced load levels. Option available only on MAP140-1012 and MAP140-1024. Power fail is standard on MAP140-3000P. Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature condition. Automatic recovery. Where available, Power Fail signal is initiated prior to shutdown. Power Fail Signal Thermal Shutdown DIMENSIONS 7.19" x 4.50" x 2.40" (182.6mm x 114.3mm x 61.0mm) 7.19" x 4.50" x 2.40" (182.6mm x 114.3mm x 61.0mm) OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm) OVERALL WEIGHT: 1.3 LBS (0.59 kg) Contact factory for dimensions for L-bracket and cover. 3 N/A N/A