MINT1400A 400W Single Output Series Medical – Universal Input Power Supply 2 Year Warranty •Compact 3.94” x 7” x 1.58”, 1U compatible •9.5 W/in³ •300W Convection Rating •Efficiency up to 91% •12Vdc to 48Vdc outputs, up to 400W •Remote ON/OFF by PS-ON Signal •Safety approved to Medical and ITE Standards • EN/IEC/UL60601-1 and CSA 601.1 •CSA/EN/IEC/UL60950-1, 2nd Edition •Compliant to EN55011/22 Conducted Noise, Class B •RoHS Compliant – Category 6 Specifications AC Input All Specifications are typical at nominal input, full load at 25°C unless otherwise stated. 80-270VAC, 47-63 Hz single phase. (See Note 1) Turn On Time 500mSec maximum 120VAC: 4.2A, 230VAC: 2.1A Hold-up Time 20 ms at 400W Input Current Input Inrush Current Input Active circuit, 37A max Input Fuses F1, F2: 6.3A Power Factor Efficiency 0.99 typical, 0.96 minimum Typical 88% @ 120VAC, 91% @ 240VAC Remote Sense Overvoltage Protection Switching Frequency Output Voltages See chart. Voltages adjustable +/- 5% Earth Leakage Current Total Regulation See chart Not required Transient Response 500µs to 1%, 0.2A/µs, 3.5% Deviation Shock and Vibration Shock: MIL-STD-810E, 516.4 part IV Vibration: 5Hz – 500Hz, 2.5 Grms Cycling type, 470W typical Overtemperature Protection Provided on all models, autorecovery. See page 2 for cooling information Compensates for up to 500mV drop on output leads Output Power 400W with fan cooling. See derating chart for other conditions. Peak: 450W for 1 min., 10% duty cycle Ripple and Noise 1% pk-pk max., 20MHz BW, differential mode Minimum Load See chart Overload Protection Safety Standards Isolation Operating Temperature Storage Temperature Relative Humidity Output: 170kHz ± 8kHz; PFC: 90kHz, ± 8kHz; Bias: 100kHz, ± 6 kHz Medical: EN/IEC/UL 60601-1, CSA 601.1 ITE: CSA/EN/IEC/UL 60950-1, 2nd Edition Input-Output: 4000VAC, Input-Ground: 1500VAC, Output-Ground 100µA at 120VAC, 60Hz Normal. 400µA at 264Vac, 60Hz SFC. 0° to 70°C, refer to derating curve for ratings >40°C -40 to +85°C 5% to 95%, non-condensing Altitude Operating: -500 to 10,000 ft. Non-Operating: -500 to 40,000 ft. Model Number Key MINT 1 400 A 12 10 L 01 01 = Standard Model, 02 and higher indicates a m odified m odel. "L" = Input Connector - EBY P/N 5002-03-N-12 "10" = Output Connections - Bus Bars w ith #10 screw s Output Voltage: "12" = 12V output, "24" = 24V output, etc. Model Configuration: "A" = Original Configuration Output Pow er (Watts) - "400" = 400W # of Outputs Product Fam ily: "M" = Medical, "I" = Internal, "NT" = New Technology ______________________________________________________________________________________________________________________________ 1 of 3 SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com MINT1400A 400W Single Output Series Medical – Universal Input Power Supply 2 Year Warranty Output Parameters Model Number Output Volts (V) MINT1400A1210L01 Output Current Fan Cooled Convection 12V 33.0A Ripple & Noise 25.0A Total Regulation 1% 2% MINT1400A2410L01 24V 16.7A 12.5A 1% 2% MINT1400A2810L01 28V 14.3A 10.7A 1% 2% MINT1400A4810L01 48V 8.30A 6.30A 1% 2% Note 1: When the input voltage is <90Vac, derate output power to 300W fan cooled, or 250W convection. Signals Inhibit: TTL LOW to inhibit PS Off: TTL HIGH to inhibit Pwr OK TTL HIGH when AC is OK, 100-200 mS delay. Pwr OK PF LOW 4 mS warning before loss of output regulation. DC OK: HIGH when output is >90% of nominal Fan Output: 12Vdc @ 250 mA. 5V Standby Voltage: Always on, up to 100mA. EMI/EMC Compliance Conducted Emissions EN55011/22 Class B Radiated Emissions EN55011/22 Class A Voltage Fluctuations EN61000-3-3, complies Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz.. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11 criteria A @ 250 Watts or less. Line Frequency Harmonics EN61000-3-2, Class A Output Power Derating Curve MINT1400 Output Power Derating Chart Output Power (Watts) 450 400 350 300 Note: For convection cooling, the power supply is required to be mounted on a heatsink or system chassis with a minimum of 150 in² of surface area. 250 200 External 200 lfm Fan Convection 150 100 50 0 0 10 20 30 40 50 60 70 Ambient Temperature (deg C) ______________________________________________________________________________________________________________________________ 2 of 3 SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com MINT1400A 400W Single Output Series Medical – Universal Input Power Supply 2 Year Warranty Outline Drawing & Connector Information Connector Information SIGNAL CONNECTOR (J3) (optional): INPUT CONNECTOR (TB1): Pin 1 AC Line Pin 2 Pin 3 Neutral Ground Manufacturer's P/N: EBY P/N 5002-03-N-12 Pin 1 PS OFF Pin 5 RTN Pin 2 Pin 3 Pin 4 INHIBIT PWR OK DC OK Pin 6 Pin 7 Pin 8 +5V Standby SENSE + SENSE Manufacturer's P/N: AMP P/N 640456-8 DC OUTPUT CONNECTORS (TB2): Pin 1 +Vout Pin 2 -Vout Manufacturer's P/N: Bus bars with #10 screws FAN OUTPUT CONNECTOR (J4) (optional): Pin 1 +12V @ .25A Pin 2 RTN Manufacturer's P/N: AMP P/N 640456-2 MATING CONNECTORS: Mate For: J1 TB2 Manufacturer's P/N: #6-32 Lug, 0.325 Center Wire - sized for output current rating. Options: Signals Fan Output Mate For: J3 J4 Manufacturer's P/N: AMP P/N 1375820-8, Pins: 1375813-3 AMP P/N 1375820-2, Pins: 1375813-3 Data Sheet © 2011 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. Rev. 3-12-2013 However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. ______________________________________________________________________________________________________________________________ 3 of 3 SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 • Phone 805.486.4565 • Fax 858.712.2040 • Email: [email protected] • www.slpower.com