AIMTEC AM12E-FZ

Series AM12E-FZ
Picture coming soon
FEATURES:
•
•
•
•
•
Models
Single output
Model
AM12E-1203SH30-FZ
AM12E-1205SH30-FZ
AM12E-1212SH30-FZ
AM12E-1215SH30-FZ
AM12E-2403SH30-FZ
AM12E-2405SH30-FZ
AM12E-2412SH30-FZ
AM12E-2415SH30-FZ
AM12E-4803SH30-FZ
AM12E-4805SH30-FZ
AM12E-4812SH30-FZ
AM12E-4815SH30-FZ
12 Watt | DC-DC Converter
Remote On / Off Control
Wide 2:1 input range
High efficiency up to 87%
Industry Standard Package
No minimum load
•
•
•
•
Input Voltage
(V)
Output Voltage
(V)
Output Current
Max (mA)
Capacitance
load, max (μF)
Input Voltage
(V)
Output Voltage
(V)
Output Current
Max (mA)
Capacitance
load, max
(μF)
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
3500
2400
1000
800
3500
2400
1000
800
3500
2400
1000
800
Models
Dual output
Model
Operating temperature -40oC to + 85oC
Input / Output Isolation 3000VDC
Continuous short circuit protection
Over Voltage Protection
4700
3300
680
330
4700
3300
680
330
4700
3300
680
330
Efficiency
(%)
77
82
86
85
77
82
87
86
78
82
87
86
Efficiency
(%)
AM12E-1205DH30-FZ
9-18
±5
±1200
±1000
82
AM12E-1212DH30-FZ
9-18
±12
±500
±220
86
AM12E-1215DH30-FZ
9-18
±15
±400
±200
85
AM12E-2405DH30-FZ
18-36
±5
±1200
±1000
83
AM12E-2412DH30-FZ
18-36
±12
±500
±220
87
AM12E-2415DH30-FZ
18-36
±15
±400
±200
86
AM12E-4805DH30-FZ
36-75
±5
±1200
±1000
83
AM12E-4812DH30-FZ
36-75
±12
±500
±220
87
AM12E-4815DH30-FZ
36-75
±15
±400
±200
86
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Transient response time
(50% load step)
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Remote Control Pin
www.aimtec.com
F 051e R12
Nominal
12
24
48
12 Vin
24 Vin
48 Vin
Typical
9-18
18-36
36-75
Maximum
Units
VDC
π(PI )
2000
µs
550
-0.7-25
-0.7-50
-0.7-100
ms
100
Open or 3.5V ~12V, <0.2mA
Short or 0V ~ 1.2V, <3mA
ON
OFF
Tel: +1 514 620 2722
1 of 4
VDC
ms
Vdc
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM12E-FZ
12 Watt | DC-DC Converter
Input Specifications (continued)
Parameters
No Load Input Current
Input reflected current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Nominal
Conditions
Temperature coefficient
Ripple & Noise
Rising time
Parameters
Pin Out Specifications
Pin
1
2
3
4
5
6
Single
+V Input
-V Input
+V Output
Trim
-V Output
Remote On/Off
www.aimtec.com
F 051e R12
Typical
(full load)
±1
Continuous
Auto Recovery
150
±0.5
±1
±0.5
±0.5
±5
±0.02
100
10
% of full load
HL-LL
0% to 25%
25% to 100%
Balanced Load (Dual)
Unbalanced 25-100% FL
20MHz Bandwidth
3.3V model
5V model
12V model
15V model
General Specifications
Conditions
Rated
> 1000
500
Conditions
Over Voltage Protection
(Zener Diode)
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Potting Material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
31
Typical
3 sec
Parameters
Load voltage regulation
Maximum
130
Output Specifications
Voltage accuracy
Short Circuit protection
Short circuit restart
Over load protection
Line voltage regulation
Typical
100% load
See derating chart
Typical
300
-55 to +105
Units
mA
mAp-p
Units
3000
VDC
MOhm
pF
Maximum
Units
%
%
%
%
3.9V
6.2V
15V
18V
Maximum
-40 to +85
Free air convection
100
% oC
mVp-p
ms
VDC
Units
KHz
o
C
o
C
o
C
95
%
Nickel coated copper
UL94V-0 rated
30
g
Tolerance ±0.5mm
2.00 x 1.00 x 0.40 inches
50.80 x 25.40 x 10.2 mm
> 1,960,000 hrs. (MIL-HDBK -217F, Ground Benign, t=+25oC)
o
1.5mm from case max 10 sec
260
C
Dual
+V Input
-V Input
+V Output
Common.
-V Output
Remote On/Off
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM12E-FZ
12 Watt | DC-DC Converter
2.54
(0.10)
Dimensions
50.80
(2.00)
DIA
1.00
(0.04)
20.32
(0.80)
15.24
(0.60)
10.16
(0.40)
5
6
15.24
(0.60)
Notes:
All dimensions are typical
in millimeters (inches).
Tolerance ±0.5 (±0.02)
5.08
(0.20)
Min
10.16
(0.40)
Isolative Plastic base
plate
4
10.16
(0.40)
Bottom View
2
2.54
(0.10)
25.40
(1.00)
7.62 5.08
(0.31) (0.20)
1
2.54
(0.10)
10.16
(0.40)
3
Derating
Free Air Convection
71 º C
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
71
Ambient Temperature
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
3 of 4
80
85
100
ºC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM12E-FZ
12 Watt | DC-DC Converter
TRIM Function
Vo+
TRIM
Vo+
R1
TRIM
Vo-
Vo-
AM12E-FZ
TRIM DOWN
AM12E-FZ
TRIM UP
3.3 V Output
Percentage
R1 ( kΩ)
10%
R2
5 V Output
R2 ( kΩ)
Percentage
R1 ( kΩ)
0
10%
0
7.5%
7.83
7.5%
3.86
5%
28.25
5%
14.8
2.5%
89.49
2.5%
47.59
R2 ( kΩ)
-10%
10.63
-10%
0
-7.5%
27.92
-7.5%
1.08
-5%
62.5
-5%
12.28
-2.5%
166.26
-2.5%
45.89
12 V Output
Percentage
R1 ( kΩ)
10%
15 V Output
R2 ( kΩ)
Percentage
R1 ( kΩ)
0
10%
0
7.5%
4.74
7.5%
5.33
5%
16.11
5%
17
2.5%
50.22
2.5%
52
R2 ( kΩ)
-10%
39.19
-10%
59
-7.5%
61.01
-7.5%
88.17
-5%
104.64
-5%
146.5
-2.5%
235.53
-2.5%
321.5
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only