Series AM8T-Z 8 Watt | DC-DC Converter FEATURES: RoHS compliant 24 Pin DIP Package Wide 2:1 input range Efficiency up to 85% Operating temperature -40oC to + 85oC Continuous Short Circuit Protection Low ripple and noise Input/output Isolation voltage 1500VDC Models Single output Model Input Voltage (V) AM8T-1203SZ AM8T-1205SZ AM8T-1212SZ AM8T-1215SZ AM8T-2403SZ AM8T-2405SZ AM8T-2412SZ AM8T-2415SZ AM8T-4803SZ AM8T-4805SZ AM8T-4812SZ AM8T-4815SZ Output Voltage (V) Output Current max (mA) Capacitive load (μF) Efficiency (%) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 2000 1500 665 535 2000 1500 665 535 2000 1500 665 535 3300 2200 470 220 3300 2200 470 220 3300 2200 470 220 80 82 85 83 80 82 85 84 80 82 84 84 Output Voltage (V) Output Current max (mA) Capacitive load (μF) Efficiency (%) ±5 ±12 ±15 ±5 ±12 ±15 ±5 ±12 ±15 ±800 ±335 ±265 ±800 ±335 ±265 ±800 ±335 ±265 ±1000 ±220 ±100 ±1000 ±220 ±100 ±1000 ±220 ±100 82 84 84 82 83 85 82 85 85 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 Models Dual output Model Input Voltage (V) AM8T-1205DZ AM8T-1212DZ AM8T-1215DZ AM8T-2405DZ AM8T-2412DZ AM8T-2415DZ AM8T-4805DZ AM8T-4812DZ AM8T-4815DZ 9-18 9-18 9-18 18-36 18-36 18-36 36-72 36-72 36-72 Input Specifications Parameters Voltage range Nominal Typical 12 24 48 9-18 18-36 36-72 Peak Input Voltage time www.aimtec.com F 051e R12.G Units VDC (Pi) Network Filter Turn on Transient process time Start up time Absolute Maximum Rating Maximum 12 Vin 24 Vin 48 Vin 20 -0.7-24 -0.7-40 -0.7-100 100 Tel: +1 514 620 2722 1 of 3 350 ms ms VDC ms Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8T-Z 8 Watt | DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Case/input & Output Resistance Capacitance Typical Rated Units 1500 VDC VDC MOhm pF Maximum Units 3 sec 1000 > 1000 1000 Output Specifications Parameters Voltage accuracy Voltage balance (Dual output model) Short Circuit protection Short Circuit restart Current Limiting Line voltage regulation Load voltage regulation Temperature coefficient Rising time Ripple and Noise Conditions Typical Balanced Load ±1 ±1 % % Continuous Auto recovery 140 % of Iout max HL-LL 10% to 100% load ±0.5 ±0.5 ±0.02 10 75 % % %/oC ms mVp-p General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 330 KHz o Operating temperature With Derating above 55°C -40 to +85 C o Storage temperature -40 to +125 C o Max Case temperature +100 C Cooling Free air convection Humidity 95 % Case material Nickel coated cooper Weight 17 g Dimensions (L x H x W) Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm MTBF >1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency Approval Standards www.aimtec.com F 051e R12.G CE nd IEC 60950-1:2005 (2 Edition); EN 60950-1:2006 EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 220uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM8T-Z 8 Watt | DC-DC Converter Single Dual 2 3 9 11 14 16 22 23 -V Input -V Input No pin N.C. +V Output -V Output +V Input +V Input -V Input -V Input Common -V Output + V Output Common +V Input +V Input 3.05 (0.12) 10.20 (0.40) Pin 15.24 (0.60) Dimensions (Bottom view) 20.30 (0.80) Pin Out Specifications Derating Test Circuits Conducted Emissions: NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only